Ultrasonic Flow Test Instrument PCE-UFM 25
£ 828.00
Price excl. VAT &. delivery
With our ultrasonic flow test instrument, you have the capability to measure flow rates from ±0.1 m/s to ±5 m/s. The ultrasonic flow test instrument is suitable for small pipes with a diameter of DN25 / 1"and various pipe materials such as steel, copper, aluminum, and plastics.

  • Measurement Range: 0.1 … 5 m/s
  • Resolution: 0.001 m/s
  • Accuracy: 2%
  • Pipe Size: DN25 / 1"
  • Display Type: OLED
  • Analog Output: 4 … 20mA
Data Logger PCE-MPC 25
£ 940.00
Price excl. VAT &. delivery

The data logger is used in offices, workshops or in laboratories to carry out indicative measurements of the environmental conditions. In addition to the number of particles, the data logger determines the mass concentration of PM2.5 and PM10 in the measuring range 0 … 1000 µg/m³.

  • Measurable particle sizes: PM2.5 / PM10
  • Particle sizes: 0.3 / 0.5 / 1.0 / 2.5 / 5.0 and 10 µm
  • Mass concentration
  • Particle counter
  • Temperature
  • Humidity (RH)
  • Flash memory for approx. 12 measurement runs

Environmental Meter PCE-MPC 25
£ 940.00
Price excl. VAT &. delivery

The environmental meter is used in offices, workshops or in laboratories to carry out indicative measurements of the environmental conditions. In addition to the number of particles, the environmental meter determines the mass concentration of PM2.5 and PM10 in the measuring range 0 … 1000 µg/m³.

  • Measurable particle sizes: PM2.5 / PM10
  • Particle sizes: 0.3 / 0.5 / 1.0 / 2.5 / 5.0 and 10 µm
  • Mass concentration
  • Particle counter
  • Temperature
  • Humidity (RH)
  • Flash memory for approx. 12 measurement runs

Aerosol meter PCE-MPC 25
£ 940.00
Price excl. VAT &. delivery

The Aerosol meter is used in offices, workshops or in laboratories to carry out indicative measurements of the environmental conditions. In addition to the number of particles, the Aerosol meter determines the mass concentration of PM2.5 and PM10 in the measuring range 0 … 1000 µg/m³.

  • Measurable particle sizes: PM2.5 / PM10
  • Particle sizes: 0.3 / 0.5 / 1.0 / 2.5 / 5.0 and 10 µm
  • Mass concentration
  • Particle counter
  • Temperature
  • Humidity (RH)
  • Flash memory for approx. 12 measurement runs

 

Environmental Tester PCE-MPC 25
£ 940.00
Price excl. VAT &. delivery

The environmental tester is used in offices, workshops or in laboratories to carry out indicative measurements of the environmental conditions. In addition to the number of particles, the environmental tester determines the mass concentration of PM2.5 and PM10 in the measuring range 0 … 1000 µg/m³.

  • Measurable particle sizes: PM2.5 / PM10
  • Particle sizes: 0.3 / 0.5 / 1.0 / 2.5 / 5.0 and 10 µm
  • Mass concentration
  • Particle counter
  • Temperature
  • Humidity (RH)
  • Flash memory for approx. 12 measurement runs

Particle Counter PCE-MPC 25
£ 940.00
Price excl. VAT &. delivery

The particle counter is used in offices, workshops or in laboratories to carry out indicative measurements of the environmental conditions. In addition to the number of particles, the particle counter determines the mass concentration of PM2.5 and PM10 in the measuring range 0 … 1000 µg/m³.

  • Measurable particle sizes: PM2.5 / PM10
  • Particle sizes: 0.3 / 0.5 / 1.0 / 2.5 / 5.0 and 10 µm
  • Mass concentration
  • Particle counter
  • Temperature
  • Humidity (RH)
  • Flash memory for approx. 12 measurement runs

Aerosol particle counter PCE-MPC 25
£ 940.00
Price excl. VAT &. delivery

The Aerosol particle counter is used in offices, workshops or in laboratories to carry out indicative measurements of the environmental conditions. In addition to the number of particles, the Aerosol particle counter determines the mass concentration of PM2.5 and PM10 in the measuring range 0 … 1000 µg/m³.

  • Measurable particle sizes: PM2.5 / PM10
  • Particle sizes: 0.3 / 0.5 / 1.0 / 2.5 / 5.0 and 10 µm
  • Mass concentration
  • Particle counter
  • Temperature
  • Humidity (RH)
  • Flash memory for approx. 12 measurement runs

 

Data Logger with USB Interface PCE-MPC 25
£ 940.00
Price excl. VAT &. delivery

The data logger with USB interface is used in offices, workshops or in laboratories to carry out indicative measurements of the environmental conditions. In addition to the number of particles, the data logger with USB interface determines the mass concentration of PM2.5 and PM10 in the measuring range 0 … 1000 µg/m³.

  • Measurable particle sizes: PM2.5 / PM10
  • Particle sizes: 0.3 / 0.5 / 1.0 / 2.5 / 5.0 and 10 µm
  • Mass concentration
  • Particle counter
  • Temperature
  • Humidity (RH)
  • Flash memory for approx. 12 measurement runs

Temperature Data Logger PCE-MPC 25
£ 940.00
Price excl. VAT &. delivery

The temperature data logger is used in offices, workshops or in laboratories to carry out indicative measurements of the environmental conditions. In addition to the number of particles, the temperature data logger determines the mass concentration of PM2.5 and PM10 in the measuring range 0 … 1000 µg/m³.

  • Measurable particle sizes: PM2.5 / PM10
  • Particle sizes: 0.3 / 0.5 / 1.0 / 2.5 / 5.0 and 10 µm
  • Mass concentration
  • Particle counter
  • Temperature
  • Humidity (RH)