2 year Warranty
The torque meter serves for detection of the loosening torque as well as for tightening of screws. Simultaneously the torque meter can be used as a monitoring instrument. The torque test instrument provides a keyed chuck with two steady handles.
- Measuring range: 5 Nm (0,5 kgf-m) / 3.69 ft-lb
- Max. 0,5 % accuracy from the measuring range
- Measuring rate freely adjustable up to 1000 Hz
- 24 Bit Processor
- Keyed chuck up to Ø 13 mm
PCE-VE 390N is the ideal industrial borescope or snake inspection camera for the analysis of buildings (walls, supports, eaves, gutters, attics, crawl spaces), plumbing (pipes, drains, sewers, wells) and heating, ventilation, air conditioning and refrigeration (HVACR) systems (ducts, furnaces, chimneys, boiler and condenser tubes). The IP68-rated cable of this inspection camera is waterproof and heavy duty, making the PCE-VE 390N well suited for use in tough environments like construction sites and industrial installations.
- Camera head diameter: 28 mm / 1.1"
- Camera cable length: 10 m / 32 ft 9"
- Interface: Mini-USB 1.1 and AV out
- Memory: 8 GB SD memory card (incl.)
- Especially suitable for chimneys, downpipes, ventilation ducts etc.
PCE-1000N is a portable handheld Barcol hardness tester used to measure the hardness of pure aluminum, soft aluminum, thick aluminum alloy and aluminum sheets, strips, rods, castings and forgings. The hardness of fiber-reinforced (FRP) plastics, glass-reinforced (GRP) plastics, hard plastics and soft metals (such as copper or lead) also can be tested using this battery-powered digital Barcol impressor hardness meter.
- Measurement parameters: Barcol (HBA), Brinell (HB), Vickers (HV), Webster
(HW)
Rockwell (HRB / HRE / HRF / HRH)
- Measuring range: 0 ... 100 HBA / 25 ... 150 HB
- Accuracy: 81 ... 88 HBA: ± 1 HBA / 42 ... 48 HBA: ± 2 HBA
- Repeatability: 81 ... 88 HBA: ± 1.5 HBA / 42 ... 48 HBA: ± 2.5 HBA
- Resolution: 0.1 HBA
- Meets ASTM standards: E140-97; D2583-75; B648-78
- Measurement geometry: 60° degree angle
- Measurement up to 1000 gloss units
- Internal reading memory up to 5000 readings
- 3.5" TFT display
- Light source: D65
- Wave length: 400-700 nm
The PCE-TG 300-NO5/90 is an NDT test instrument for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the NDT test instrument. Wall thicknesses under a coating can also be measured with the NDT test instrument.
- Measuring range: 1 ... 600 mm / 0.039 ... 23.62" (steel)
- Diameter: 10mm / 0.39"
- Sensor at 90° angle
- Minimum diameter of pipes: 20 x 3 mm / 0.787 ... 0.118"
- Frequency: 5 MHz
- Bluetooth
PCE-IVE 300 is an NDT test instrument or video borescope inspection camera that comes with a rigid telescoping pole that extends up to 1 m (3.28') in length. Ideal for inspecting gutters, chimneys and structures as well as for inspecting parts and under vehicles, the NDT test instrument captures both picture and video and saves the files to an SD card memory (included).
- Telescopic pole extends up to 1 m / 3.3 ft
- Gooseneck camera head diameter of 28 mm / 1.11 in
- Waterproof and dustproof IP68 ingress protection rating
The PCE-IVE 330 NDT test instrument or inspection camera is used to diagnose and monitor hard-to-reach areas on vehicles, containers, machinery and equipment. Thanks to the 3 m / 9.8 ft telescopic rod of the NDT test instrument, it is also possible to view areas that are difficult to access. Visual monitoring with the videoscope is supported by the flexible camera head.
- Camera length: 320 mm / 12.5"
- Camera diameter: 23 mm / 0.9"
- Flexible camera head
- 8" LCD monitor
- Memory function
PCE-VE 360N is a small-diameter industrial borescope or borescope camera for the non-destructive inspection (NDI) of engines, machines and more. This industrial borescope is an ideal tool for diagnosing issues in hard-to-reach places. The waterproof camera head of this kind of borescope features 3 LED lights with automatic illumination. In addition, digital image magnification or zoom of up to 2 times is available.
- 1 m / 3ft 3" camera cable with front camera
- 1 m / 3ft 3" camera cable with 90° side camera
- Diameter camera head: Ø 3.9 mm / 0.15"
- Interface: Mini-USB 1.1 and AV out/in
- Memory: 8 GB SD memory card (incl.)
- Cable length: 1 m / 3ft 3"
PCE-IVE 320 is a endoscope, inspection camera, videoscope or industrial borescope that comes with a rigid telescoping pole that extends up to 2.3 m (7.55') in length (3 m long total with camera connection). Plus, the endoscope's 0.3 megapixel camera has a 23 mm (0.91") diameter flexible head with microphone and 12 white LEDs offering adjustable brightness. Includes wheel attachment for under vehicle inspection.
- Telescopic pole extends up to 2.3 m / 7.6 ft
(3 m /9.8 ft long total with camera connection)
- 12.7 cm / 5" LCD monitor with 800 x 480 pixel resolution
- Video recording capability
- Accommodates SD memory cards from 2 ... 32 GB
- Spare battery to allow all day operation
The PCE-HT 71N Hygrometer Data Logger detects air temperature and humidity and stores readings in its internal memory. The Hygrometer Data Logger has a compact format and a wide memory capacity (up to 32,000 values / 16,000 values for each parameter) and it is mainly used as a Data Logger in fields such as supermarket refrigeration units, refrigerated transport, warehouses, and other temperature controlled environments.
- Measurement range: 0 ... 100% RH / -35 ... 80°C / -31 ... 176°F
- Accuracy: ± 3% RH (20 ... 80%) and ± 5% / ± 1°C (1.8°F)
- Resolution: 0.5% RH / 0.1°C (0.18°F)
- Memory: Max. 32,000 measurement data (16,000 for each parameter (humidity / temperature))
The PCE-HT 71N Temperature Meter detects air temperature and humidity and stores readings in its internal memory. The Temperature Meter has a compact format and a wide memory capacity (up to 32,000 values / 16,000 values for each parameter) and it is mainly used as a Temperature Meter in fields such as supermarket refrigeration units, refrigerated transport, warehouses, and other temperature controlled environments.
- Measurement range: 0 ... 100% RH / -35 ... 70°C / -31 ... 158°F
- Accuracy: ± 3% RH (20 ... 80%) and ± 5% / ± 1°C (1.8°F)
- Resolution: 0.5% RH / 0.1°C (0.18°F)
- Memory: Max. 32,000 measurement data (16,000 for each parameter (humidity / temperature))