2 year Warranty
PCE-T 1200 is a 12-channel HVAC meter that accommodates SD cards up to 16 GB in size. The optional software allows the HVAC meter to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
- Includes 2 Type K sensors 1-meter in length
PCE-T 1200 is a 12-channel climate meter that accommodates SD cards up to 16 GB in size. The optional software allows the temperature meter to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
- Includes 2 Type K sensors 1-meter in length
- incl. ISO Calibration Certificate
The PCE-VA 20-SET is a multi-functional relative humidity meter including flow hoods for assessing and balancing heating, ventilation and air conditioning or cooling (HVAC) installations. This multi-faceted anemometer-thermometer-hygrometer incorporates a 10 cm / 3.9" diam. fan impeller, easy-to-view backlit LCD, and useful functions, e.g. display hold, average val, maximum val, minimum val, auto power-off, low battery indication, and imperial/metric option.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew
point temperature and wet-bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±(3% of
measured value + 0.3 m/s) when more than 20 m/s
- Resolution: 0.1°C / 0.18°F
- Includes 2 x capture hoods (1 x round 210 mm / 8.3 in Ø, 1 x square 346 x 346
mm / 13.6 x 13.6 in)
- incl. ISO Calibration Certificate
PCE-T 1200 is a 12-channel data-logging digital thermometer that accommodates SD cards up to 16 GB in size. The optional software allows the digital thermometer to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable data-logging interval from 1 ... 3600 seconds per channel
PCE-T 1200 is a 12-channel datalogging digital thermometer that accommodates SD cards up to 16 GB in size. The optional software allows the digital thermometer to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
PCE-T 1200 is a 12-channel datalogging temperature meter that accommodates SD cards up to 16 GB in size. The optional software allows the temperature meter to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
PCE-T 1200 is a 12-channel temperature data logger that accommodates SD cards up to 16 GB in size. The optional software allows the temperature data logger to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
This data logger with USB interface is a 12-channel temperature data logger that accommodates SD cards up to 16 GB in size. The optional software allows the data logger to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
This 12-channel temperature data logger accommodates SD cards up to 16 GB in size. The optional software allows the temperature meter to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
The compact balance PCE-SD 30C is a low-cost robust verifiable system balance. The calibration of the compact balance is according to the trading class M III. The sturdy foundation of the compact balance is made of painted steel and features a plastic-coated steel platform.
- Weighing capacity: 30 kg
- Readability: 10 g
- Minimum load: 200 g
- Platform size: 400 x 500 mm
- Certifiable: M III
PCE-WM1-ICA is a multi-function relative humidity meter used to determine relative humidity (% RH), absolute humidity (g/m³), air temperature, dew-point temperature and surface temperature (°C). This Metric-only measuring instrument comes complete with an external sensor probe for taking the surface temperature of different materials.
- Temperature range: -20 ... 80°C
- Relative humidity range: 10 ... 95% RH
- Absolute humidity range: 0.5 ... 74.4 g/m³
- incl. ISO Calibration Certificate
With the relative humidity meter it is possible to measure climate conditions such as temperature and relative humidity, as well as determining surface temperature of objects simultaneously by using the included external temperature sensor or using an infrared measurement. The relative humidity meter offers features such as average value, maximum, minimum, and hold functions at a reasonable price.
- Internal probe
- Temperature: -20°C ... 60°C / -4 ... 140°F
- Relative humidity: 10 ... 90% r.H.
- Temperature of global: -22°C ... 60°C / -8 ... 140°F
- Humidity: -68°C ... 60°C / -90 ... 140°F
- Dew point temperature: depending on the sensor
- External probe
- Temperature: -50° C ... 500° C / -58 ... 932°F
- incl. ISO Calibration Certificate
PCE-MA 110 is a halogen relative humidity meter or analyzer that functions on the gravimetric or loss on drying (LOD) principle. The relative humidity meter uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the relative humidity meter can be performed at any time using the automatic calibration function and the included 100 g weight.
- Weighing range: 0.1 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.01 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
- RS-232 interface or port
Affordable Compact Balance. The balance can be calibrated (2100 g), weighing units can also be selected, with piece counting function.