2 year Warranty
The HVAC meter PCE-PDA 1L is a reliable differential pressure gauge for pressure measurement of gasses in the range of ± 2 kPa. The HVAC meter PCE-PDA 1L has many different pressure measuring functions.
- Measuring range: ± 2000 Pa / ± 0.29 psi / ± 0.02 bar
- Resolution: 1 Pa / 0.000145 psi / 0.00001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
PCE-EM 29 is a portable handheld electromagnetic radiation detector with a spherical triaxial (3-axis) three-dimensional (3D) isotropic sensor used to measure electromagnetic fields (EMFs) as well as radio frequencies (RFs). This easy-to-use battery-powered RF meter features a large 4-digit LCD screen and an adjustable value limit with acoustic alarm functionality.
- Frequency range: 50 MHz to 3.5 GHz
- Measures EMF of 5G cellular Low-band and Mid-band
- Measurement range: 38 mV/m to 11 V/m
- Accuracy: ±1.0 dB (50 MHz to 1.9 GHz), ±2.4 dB (1.9 GHz to 3.5 GHz)
- Displays units in mV/m, V/m, µgA/m, mA/m, µgW/m² or mW/m²
- Calculates average value and stores up to 99 readings to memory
The HVAC meter PCE-PDA 10L is a reliable differential pressure gauge for pressure measurement of gases in the range of ±20 kPa. The HVAC meter PCE-PDA 10L has many different pressure measuring functions.
- Measuring range: ± 20 kPa / ± 2.9 psi / ± 0.2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
- Pitot tube not included in delivery / optionally selectable
The HVAC meter PCE-PDA 100L is a reliable differential pressure gauge for pressure measurement of gases in the range of -100 to +200 kPa. The HVAC meter PCE-PDA 100L has many different pressure measuring functions.
- Measuring range: -100 ... 200 kPa / -14.5 ... 29 psi / -1 ... 2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
PCE-WM1-ICA is a multi-function HVAC meter used to determine relative humidity (% RH), absolute humidity (g/m³), air temperature, dew-point temperature and surface temperature (°C). This Metric-only measuring instrument comes complete with an external sensor probe for taking the surface temperature of different materials.
- Temperature range: -20 ... 80°C
- Relative humidity range: 10 ... 95% RH
- Absolute humidity range: 0.5 ... 74.4 g/m³
- incl. ISO Calibration Certificate
The HVAC meter is a automotive tester / borescope or inspection camera, for nondestructive evaluation (NDE) and machine diagnostics. The HVAC meter automotive tester provides excellent image quality at an affordable price. An ideal camera tool for diagnosing hard-to-reach places, the scope can be rotated 180 ° and offers 6 LED lights with adjustable intensity for optimal illumination. In addition, digital image magnification or zoom of up to 4 times is available.
Automotive Tester
- 3.5 in LCD display
- 3.28 ft cable length
- 0.18 in camera cable diameter
- 1/8 in camera head / CMOS chip image sensor
- 640 x 480 pixels AVI video resolution
- Micro SD card memory
- Micro USB 2.0 and TV outputs
Clamp Meter
This Clamp Meter has been developed to determine indirectly, the the AC/DC currents with high accuracy. A non-contact clamp meter and a torch to illuminate the area being measured, have been integrated into this device. The small size of this Clamp Meter, makes it possible to use in small spaces with limited access.
- 4 digit LCD display with backlighting
- save function
- DCA zero rest function
- current tester, non-contact
- integrated light to illuminate measured area
- automatic range selection
- automatic disconnect
- clamp diameter: 18 mm
This HVAC meter is used for single-phase or three-phase measurements of the active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics up to 50º of the harmonic waveform. The HVAC meter is equipped with data logger. The test instrument is delivered manufacturer calibrated (ISO or certification as an option).
- Real-time test, register and measurement of voltage and current (real and effective)
- Measures power factor and phase angle, frequency, energy, active, reactive and apparent power
(single-phase or three-phase in symmetrical networks).
- Max. conductor diameter: 55 mm / 2.2 in
- Datalogger for 50,000 readings / software/ USB interface
- incl. ISO Calibration Certificate
The PCE-HT110 HVAC Humidity / Temperature Data Logger or Humidity Detector precisely measures air temperature and relative humidity. This accurate and reliable device shows the current measurements on the large LCD display and saves the measurement data directly to an SD card (included). The PCE-HT110 is equipped with two channels, accommodates an SD card memory of up to 16 GB, offers an adjustable measurement rate / sampling interval, and includes a wall mount, making the device ideal for logging data over an extended period of time.
- Measurement ranges: 0 … 50°C / 32 ... 122°F, 10 ... 90% RH
- Resolution: 0.1°C / 0.18°F, 0.1% RH
- Data format: .XLS (compatible with Microsoft Excel)
- Set = Quantity of 5 x units