2 year Warranty
The data logger with USB interface is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy data logger with USB interface has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
PCE-VDR 10-ICA is a single-axis accelerometer or shock data logger with real-time measurement and data logging capabilities. This shock data logger records acceleration (m/s, g, ft/s) as well as velocity (mm/s, cm/s, in/s) measurements and saves the measured data to an included SD card memory. There is also an analog output, which makes this shock data logger compatlble with control systems.
- Acceleration measuring range:
0.5 ... 199.9 m/s, 0.05 ... 20.39 g, 2 ... 656 ft/s
- Velocity measuring ranges:
0.5 ... 199.9 mm/s, 0.05 ... 19.99 cm/s, 0.02 ... 7.87 in/s
- Frequency range: 10 ... 1000 Hz
- Analog output: 4 ... 20 mA
- RS-232 and USB interface
- incl. ISO Calibration Certificate
The PCE-HT 71N Data Logger detects air temperature and humidity and stores readings to its internal memory. This Data Logger is compact and has enough memory to store up to 32,000 readings, 16,000 for each parameter, and is used above all as a Data Logger, in supermarket refrigeration units, refrigerated transport, warehouses and other temperature controlled environments. These temperature and humidity logging test instruments are manufacturer calibrated. An ISO calibration certificate is an option.
- Measurement range: 0 ... 100% RH / -35 ... 80°C / -31 ... 176°F
- Accuracy: ± 3% RH (20 ... 80%) and ± 5% / ± 1°C (1.8°F)
- Resolution: 0.5% RH / 0.1°C (0.18°F)
- Memory: Max. 32,000 measurement data (16,000 for each parameter (humidity / temperature))
The data logger for temperature and humidity detects air temperature and humidity and stores readings to its internal memory. This data logger for temperature and humidity is compact and has enough memory to store up to 32,000 readings, 16,000 for each parameter, and is used above all as a data logger, in supermarket refrigeration units, refrigerated transport, warehouses and other temperature controlled environments. These temperature and humidity logging test instruments are manufacturer calibrated. An ISO calibration certificate is an option.
- Measurement range: 0 ... 100% RH / -35 ... 80°C / -31 ... 176°F
- Accuracy: ± 3% RH (20 ... 80%) and ± 5% / ± 1°C (1.8°F)
- Resolution: 0.5% RH / 0.1°C (0.18°F)
- Memory: Max. 32,000 measurement data (16,000 for each parameter (humidity / temperature))
PCE-VDR 10-ICA is a single-axis accelerometer or vibration data logger monitor with real-time measurement and data logging capabilities. This vibration data logger records acceleration (m/s, g, ft/s) as well as velocity (mm/s, cm/s, in/s) measurements and saves the measured data to an included SD card memory. There is also an analog output, which makes this vibration data logger compatlble with control systems.
- Acceleration measuring range:
0.5 ... 199.9 m/s, 0.05 ... 20.39 g, 2 ... 656 ft/s
- Velocity measuring ranges:
0.5 ... 199.9 mm/s, 0.05 ... 19.99 cm/s, 0.02 ... 7.87 in/s
- Frequency range: 10 ... 1000 Hz
- Analog output: 4 ... 20 mA
- RS-232 and USB interface
- incl. ISO Calibration Certificate
The temperature data logger is used to measure indoor / outdoor wet bulb globe temperature (WBGT), black globe temperature (TG), wet bulb temperature (WB), dew point temperature, air temperature (TA) and relative humidity. Thus, this multipurpose data recording device is an ideal tool for evaluating heat stress risks in different work environments.
- Programmable WBGT alarm setting with audible and visual alerts
- Manual (push-button) or automatic (adjustable 1 ... 3600 sec) sampling
- SD card memory (1 ... 16 GB) allows for quick and easy data transfer to a PC
The Temperature Data Logger with logging function is a versatile tool in that it can measure the temperature of objects without contact and readings can be stored in memory and transferred to a computer by way of its RS-232 interface and software. This Temperature Data Logger comes complete, allowing the user to program specific time intervals for taking measurements, such as over an entire week. These temperature logging test instruments are calibrated by the manufacturer. An ISO calibration certificate is available as an option.
- Temperature range: -40 to 500°C / -40 ... 932°F
- Resolution: 0.1°C / 0.18°F
- Accuracy: ±2% of reading or ±2°C / 3.6°F
- Optical resolution: 8:1
- Emissivity: 0.3 to 1.0 (adjustable)
- Interface: RS-232
- Display: LCD
The Temperature Data Logger with microprocessor is a high precision 1-channel temperature gauge. The Temperature Data Logger with microprocessor is ideal for use with various Pt100 sensors. These temperature logging test instruments are calibrated by the manufacturer. An ISO calibration certificate is available as an option.
- 1 channel temperature recorder
- Automatic shutdown
- High accuracy of ± 2% r.H.
- Sampling rate of 2 / sec
- Memory size: 5,000 values
This power datalogger is used for single-phase or three-phase measurements of the active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics up to 50º of the harmonic waveform. The power analyzer clamp is equipped with data logger. The test instrument is delivered manufacturer ISO calibrated.
- Real-time test, register and measurement of voltage and current (real and effective)
- Measures power factor and phase angle, frequency, energy, active, reactive and apparent power
(single-phase or three-phase in symmetrical networks).
- Max. conductor diameter: 55 mm / 2.2 in
- Datalogger for 50,000 readings / software/ USB interface
- incl. ISO Calibration Certificate
The dB data logger is used to determine volume. The PCE-NDL 10 dB data logger is a handy measuring device that meets the highest requirements. In order to evaluate the measured data in the best possible way, it is possible to use the internal measurement data memory on the noise dosimeter. In addition, the dB data logger has an SD card slot that enables the use of an SD card as an additional storage medium.
- Measuring range: SPL: Auto 30 ... 130 dB
- Resolution: 0.1 dB
- Low sampling rate
- Automatic or manual storage
- Selectable storage interval
- Backlit LC display
- Dose measurement or SPL measurement
The data logger with USB interface is used to measure indoor / outdoor wet bulb globe temperature (WBGT), black globe temperature (TG), wet bulb temperature (WB), dew point temperature, air temperature (TA) and relative humidity. Thus, this multipurpose data logger with USB interface is an ideal tool for evaluating heat stress risks in different work environments.
- Programmable WBGT alarm setting with audible and visual alerts
- Manual (push-button) or automatic (adjustable 1 ... 3600 sec) sampling
- SD card memory (1 ... 16 GB) allows for quick and easy data transfer to a PC