2 year Warranty
The PCE-313 S Thermo Hygrometer has been designed for professional use in fields such as the air-conditioning sector. The PCE-313 S Thermo Hygrometer determines both relative humidity and ambient temperature. The PCE-313 S Thermo Hygrometer can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe.
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.54 ... 120°F
The dewpoint meter has been designed for professional use in fields such as the air-conditioning sector. The dewpoint meter determines both relative humidity and ambient temperature. The dewpoint meter can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe.
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.54 ... 120°F
The PCE-313 S HVAC Meter has been designed for professional use in fields such as the air-conditioning sector. The PCE-313 S HVAC Meter determines both relative humidity and ambient temperature. The PCE-313 S HVAC Meter can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe.
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.54 ... 120°F
The automotive-testing mechanics stethoscope PCE-S 42 is designed for listening to individual machine parts. The industrial stethoscope is used to perform maintenance and repair work. The use of an industrial stethoscope thus facilitates the interception of acoustic phenomena on bearings and motors to prevent failures.
- Frequency range: 30 Hz ... 15 KHz
- For preventative maintenance and servicing
- Sound suppressing headphones included
- Easy operation
- Headphones, 70 mm long sensor, 280 mm long sensor, battery, carrying case
PCE-VE 200-S is an industrial inspection camera, endoscope or borescope for the non-destructive evaluation (NDE) of engines, machines and more. This industrial borescope provides excellent image quality at an affordable price. An ideal tool for diagnosing issues in hard-to-reach places, the waterproof camera head features 6 LED lights with adjustable intensity for optimal illumination. In addition, digital image magnification or zoom of up to 4 times is available.
- 3.7 mm / 0.14" diameter
- 1 m / 3.28' cable length
- 180° image rotation
The PCE-313 S Data Logger has been designed for professional use in fields such as the air-conditioning sector. The PCE-313 S Data Logger determines both relative humidity and ambient temperature. The PCE-313 S Data Logger can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe. These logging test instruments are calibrated by the manufacturer. An ISO calibration certificate is available as an option.
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.54 ... 120°F
The PCE-313 S Humidity Detector has been designed for professional use in fields such as the air-conditioning sector. The PCE-313 S Humidity Detector determines both relative humidity and ambient temperature. The PCE-313 S Humidity Detector can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe.
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.54 ... 120°F
The data logger for temperature and humidity has been designed for professional use in fields such as the air-conditioning sector. The data logger for temperature and humidity determines both relative humidity and ambient temperature. The data logger for temperature and humidity can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe.
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.54 ... 120°F
The PCE-313 S Relative Humidity Meter has been designed for professional use in fields such as the air-conditioning sector. The PCE-313 S Relative Humidity Meter determines both relative humidity and ambient temperature. The PCE-313 S Relative Humidity Meter can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe.
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.54 ... 120°F
The PCE-313 S Air Humidity Meter has been designed for professional use in fields such as the air-conditioning sector. The PCE-313 S Air Humidity Meter determines both relative humidity and ambient temperature. The PCE-313 S Air Humidity Meter can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe.
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.54 ... 120°F
The Temperature Data Logger has been designed for professional use in fields such as the air-conditioning sector. The Temperature Data Logger determines both relative humidity and ambient temperature. The Temperature Data Logger can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe. These logging test instruments are calibrated by the manufacturer. An ISO calibration certificate is available as an option.
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.54 ... 120°F
The process controller / temperature controller is a simple temperature controller for control tasks. The input signal of the thermostat is processed by thermocouples type S in different temperature ranges. Optionally the simple temperature controller can also be equipped with a PID switch.
- Power supply: 85 ... 253 V AC / DC
- Sensor Input: Thermocouple type S
- Measuring ranges: up to max. 1600 °C
- Output: Relay or SSR output (selectable)
The PCE-S 41 Vibration Analyser is battery powered and easy to use. This Vibration Analyser can be used for detecting noise in machine components, such as gears, valves, vents, and pumps.
- Frequency range: 100 Hz to 10 kHz
- headphones, 70 mm sensor, 290 mm sensor, battery, carrying case
- Weight: 240 g, with battery
The PCE-S 41 Vibration Meter is battery powered and easy to use. This Vibration Meter can be used for detecting noise in machine components, such as gears, valves, vents, and pumps.
- Frequency range: 100 Hz to 10 kHz
- headphones, 70 mm sensor, 290 mm sensor
- Weight: 240 g, with battery
- Dimensions: 206 mm x 50 mm x 32 mm
The PCE-S 41 Mechanics Stethoscope is battery powered and easy to use. This Mechanics Stethoscope can be used for detecting noise in machine components, such as gears, valves, vents, and pumps.
- Frequency range: 100 Hz to 10 kHz
- Headphones, 70 mm long sensor, 290 mm long sensor, battery, carrying case
- Weight: 240 g, with battery
- Dimensions: 206 mm x 50 mm x 32 mm
The PCE-S 41 Condition Monitoring Stethoscope is battery powered and easy to use. This Condition Monitoring Stethoscope can be used for detecting noise in machine components, such as gears, valves, vents, and pumps.
- Frequency range: 100 Hz to 10 kHz
- Headphones, 70 mm long sensor, 290 mm long sensor
- Weight: 240 g, with battery
- Dimensions: 206 x 50 x 32 mm
The car measuring device is battery powered and easy to use. This car measuring device can be used for detecting noise in machine components, such as gears, valves, vents, and pumps.
- Frequency range: 100 Hz to 10 kHz
- headphones, 70 mm sensor, 290 mm sensor
- Weight: 240 g, with battery
- Dimensions: 206 mm x 50 mm x 32 mm