2 year Warranty
PCE-HVAC 2 is an environmental tester with a pitot tube. This portable environmental tester can be used to determine air speed, air pressure, air flow, differential pressure and ambient temperature. The pitot tube allows access through tiny openings to take measurements in small pipe systems and other confined spaces.
- Measures air velocities up to 80 m/s / 262 ft/s, 2.24 ... 178.66 MPH
- Zero, minimum, maximum, average, record and hold functions
- Stores to memory up to 99 measurement values per parameter
PCE-DRB 2 is a handheld digital refractometer used to determine the refractive index and dextran, fructose, glucose, lactose and maltose content (%) of liquid. This waterproof IP65-rated digital refractometer features automatic temperature compensation (ATC) from +10 ... +40 °C / +50 ... +104 °F, as well as a large, easy-to-read LCD that shows both the measured value and the temperature.
Measurement parameters:
- Dextran, fructose, glucose, lactose, maltose, temperature
- Measurement range: 1.3330 ... 1.5177 nD
- Resolution: 0.0001 nD
- Accuracy: ±0.0003 nD
- Automatic temperature compensation (ATC)
PCE-428 is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
PCE-428 is a class 2 data logging decibel meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy decibel meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The decibel meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
PCE-428 is a class 2 data logging noise meter / sound meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy noise meter / sound meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The noise meter / sound meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
PCE-428 is a class 2 data logging SPL meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy SPL meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The SPL meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
The stainless steel floor scale is made entirely of high quality, acid resistant stainless steel. The weighing cells installed in the stainless steel floor scale have a protection class of IP68.
- Weighing range : 6000 kg
- Readability : 2 kg
- Taring range: over the entire weighing range
- Includes initial verification
- Calibratable M III
PCE-DRW 2 is a handheld digital refractometer used to determine the sugar content / alcohol content (% vol ap) / °Oechsle (°Oe) / KMN (babo) of wine and similar liquids in the 0 ... 45 % Brix / 0 ... 22% vol ap / 3 ... 150 °Oe / 0 ... 25 KMW measuring range. This waterproof IP65-rated digital refractometer features automatic temperature compensation (ATC) from +10 ... +40 °C / +50 ... +104 °F, as well as a large, easy-to-read LCD that shows both the measured value and the temperature.
Measurement parameters:
- Brix, % vol ap, °Oechsle, KMW, temperature
- Measurement range: 0 ... 45 % Brix
- Resolution: 0.1 % Brix
- Accuracy: ±0.2 % Brix
- Automatic temperature compensation (ATC)
PCE-HVAC 2 is a high-velocity multifunction air flow meter with a pitot tube. This portable air flow meter can be used to determine air speed, air pressure, air flow, differential pressure and ambient temperature. The pitot tube allows access through tiny openings to take measurements in small pipe systems and other confined spaces.
- Measures air velocities up to 80 m/s / 262 ft/s, 2.24 ... 178.66 MPH
- Zero, minimum, maximum, average, record and hold functions
- Stores to memory up to 99 measurement values per parameter
PCE-HVAC 2 is a high-velocity multifunction wind measurer or anemometer with a pitot tube. This portable wind measurer can be used to determine air speed, air pressure, air flow, differential pressure and ambient temperature. The pitot tube allows access through tiny openings to take measurements in small pipe systems and other confined spaces.-
- Measures air velocities up to 80 m/s / 262 ft/s, 2.24 ... 178.66 MPH
- Zero, minimum, maximum, average, record and hold functions
- Stores to memory up to 99 measurement values per parameter
PCE-HVAC 2 is a high-velocity multifunction wind speed meter, measurer or anemometer with a pitot tube. This portable wind speed meter can be used to determine air speed, air pressure, air flow, differential pressure and ambient temperature. The pitot tube allows access through tiny openings to take measurements in small pipe systems and other confined spaces.-
- Measures air velocities up to 80 m/s / 262 ft/s, 2.24 ... 178.66 MPH
- Zero, minimum, maximum, average, record and hold functions
- Stores to memory up to 99 measurement values per parameter
PCE-HVAC 2 is a pitot tube anemometer used to determine air velocity, air pressure, airflow, differential pressure and ambient temperature. The pitot tube anemometer allows access through tiny openings to take measurements in small pipe systems and other confined spaces.-
- Measures air velocities up to 80 m/s / 262 ft/s, 2.24 ... 178.66 MPH
- Zero, minimum, maximum, average, record and hold functions
- Stores to memory up to 99 measurement values per parameter
PCE-HVAC 2 is a high-velocity multifunction HVAC meter with a pitot tube. This portable HVAC meter can be used to determine air speed, air pressure, air flow, differential pressure and ambient temperature. The pitot tube allows access through tiny openings to take measurements in small pipe systems and other confined spaces.-
- Measures air velocities up to 80 m/s / 262 ft/s, 2.24 ... 178.66 MPH
- Zero, minimum, maximum, average, record and hold functions