2 year Warranty
The PCE-VM 40C Vibration Recorder with SMS alert functionality was designed for vibration and shock metering on buildings, bridges, towers, and other artificial structures. The Vibration Recorder measures vibrations in accordance to DIN 4150-3, BS 7385 and SN 640312A standards. With its internal memory for up to 100,000 readings, the PCE-VM 40C Vibration Recorder can determine the effects of construction sites, traffic, or industrial processing on buildings over a long period of time. Features a micro SD card, GSM modem (optional), warning and alarm leds, relay output, SMS alerts (optional), and an internal battery.
- Designed for building / construction vibration monitoring
- Triaxial acceleration meter
- In accordance with BS 7385 standard
- SMS alarm notifications (optional)
- FFT analysis, XYZ and vector sum display
- Quad band GSM
- SMS alarm notifications
VHF-Band Moisture sensor Crushed soil, sand, stone, Gravel, Ore. The device is resistant to corrosion (stainless steel and dielectric materials) and can operate in the conditions deviating from the norm, for example, at temperatures of 250 °C. The moisture sensor probe can be mounted on the walls in the hoppers, in pipelines or on trays in conveyors. Due to pluggable design this version of the moisture sensor can also be used for soil moisture control.
- Measurement range: 0 ... 100 %
- Limits of error: <0.5% below 10% moisture
- Range of working temperatures:
0 ... +90 °C (industrial version)
0 ... +115 °C (extended temperature range)
0 ... +250 °C (drying kilns)
VHF-Band Moisture Meter Crushed Stone, Gravel, Ore (conveyor). The device is resistant to corrosion (stainless steel and dielectric materials) and can operate in the conditions deviating from the norm, for example, at temperatures of 145 °C. The humidity detector probe can be mounted on the walls in the hoppers, in pipelines or on trays in conveyors. Due to pluggable design this version of the humidity detector can also be used for soil moisture control.
- Measurement range: 0 ... 100 %
- Limits of error: <0.5% below 10% moisture
- Range of working temperatures:
0 ... +90 °C (industrial version)
0 ... +115 °C (extended temperature range)
0 ... +250 °C (drying kilns)
VHF-Band Moisture Meter Crushed Stone, Gravel, Ore (conveyor). The device is resistant to corrosion (stainless steel and dielectric materials) and can operate in the conditions deviating from the norm, for example, at temperatures of 145 °C. The moisture meter probe can be mounted on the walls in the hoppers, in pipelines or on trays in conveyors. Due to pluggable design this version of the moisture meter can also be used for soil moisture control.
- Measurement range: 0 ... 100 %
- Limits of error: <0.5% below 10% moisture
- Range of working temperatures:
0 ... +90 °C (industrial version)
0 ... +115 °C (extended temperature range)
0 ... +250 °C (drying kilns)
VHF-Band Moisture Analyzer Crushed Stone, Gravel, Ore (conveyor). The device is resistant to corrosion (stainless steel and dielectric materials) and can operate in the conditions deviating from the norm, for example, at temperatures of 145 °C. The moisture analyzer probe can be mounted on the walls in the hoppers, in pipelines or on trays in conveyors. Due to pluggable design this version of the moisture analyzer can also be used for soil moisture control.
- Measurement range: 0 ... 100 %
- Limits of error: <0.5% below 10% moisture
- Range of working temperatures:
0 ... +90 °C (industrial version)
0 ... +115 °C (extended temperature range)
0 ... +250 °C (drying kilns)
VHF-Band Moisture Analyzer Crushed Stone, Gravel, Ore (conveyor). The device is resistant to corrosion (stainless steel and dielectric materials) and can operate in the conditions deviating from the norm, for example, at temperatures of 145 °C. The moisture Analyzer probe can be mounted on the walls in the hoppers, in pipelines or on trays in conveyors. Due to pluggable design this version of the moisture analyzer can also be used for soil moisture control.
- Measurement range: 0 ... 100 %
- Limits of error: <0.5% below 10% moisture
- Range of working temperatures:
0 ... +90 °C (industrial version)
0 ... +115 °C (extended temperature range)
0 ... +250 °C (drying kilns)