The ultrasonic flow tester is a fixed installation meter. The flow rate of liquids in pipes can be determined with this flow tester. The sensors from the ultrasonic flow tester can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.
The ultrasonic flow meter is a fixed installation meter. The flow rate of liquids in pipes can be determined with this flow meter. The sensors from the ultrasonic flow meter can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.
The Clamp-on Ultrasonic Flow Meter is a fixed installation meter. The flow rate of liquids in pipes can be determined with this flow meter. The sensors from the Clamp-on Ultrasonic Flow Meter can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.
The ultrasonic flow meter is a fixed installation meter. The flow rate of liquids in pipes can be determined with this flow meter. The sensors from the ultrasonic flow meter can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.
The Ultrasonic testing device is a fixed installation meter. The flow rate of liquids in pipes can be determined with this flow tester. The sensors from the Ultrasonic testing device can be mounted directly on the pipes to be measured without having to cut them open.
The ultrasonic HVAC meter is a fixed installation meter. The flow rate of liquids in pipes can be determined with this HVAC meter. The sensors from the ultrasonic HVAC meter can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.
The Roughness Tester PCE-RT 1200-ICA is used to determine surface roughness. The compact roughness tester is a handheld device for mobile use. Due to the power supply via a powerful battery, it can be used directly on site. The roughness tester PCE-RT 1200-ICA is used in the laboratory, in production and everywhere where the roughness of surfaces is to be determined.
Measures Ra, Rz, Rq and Rt in Metric (µm) and Imperial (µinch)
The Portable Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the Portable Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.
Measuring range: ±32 m/s
Resolution: 0.001 m/s
Pipe size: DN 50 … 700 / 57 … 720 mm
Temperature resistance: -30 … 160 °C
for different media
for different pipe materials
Measuring parameters: Flow velocity, flow rate and volume