Digital Microscope PCE-IDM 3D
£ 3,895.00
Price excl. VAT &. delivery
The 3D digital microscope PCE-IDM 3D is a microscope with its own user interface, in which various analysis functions are available. The live image and the user interface are transmitted together via the VGA connection to the 3D digital microscope PCE-IDM 3D to a connected monitor.

  • 3D rotation 360°
  • Lens magnification: 0.3 … 2.2 times
  • Picture format 1920 x 1080 Full HD
  • Focusing range 250 mm / 9.8 in
Dew Point Thermometer for Compressed Air PCE-DPM 10-SFKIT incl. Smart Features
£ 3,774.00
Price excl. VAT &. delivery
The dew point thermometer for compressed air enables precise determination of the dew point in pressurised systems. Thanks to its robust design, the device can be used for industrial applications up to 15 bar.

  • Dew point measuring range from -100 … +50 °C
  • Pressure range up to 15 bar differential pressure
  • Data logger for up to 100 million measured values
  • Adjustable alarm limits
  • Touch LC display
  • Smart features:
  • Prediction of the final dew point value
  • Camera function
  • PDF report function in accordance with ISO 8573-1
HVAC Meter PCE-DPM 10-SFKIT incl. Smart Features
£ 3,774.00
Price excl. VAT &. delivery
The HVAC meter from PCE Instruments enables precise determination of the dew point in pressurised systems. Thanks to its robust design, the device can be used for industrial applications up to 15 bar.

  • Dew point measuring range from -100 … +50 °C
  • Pressure range up to 15 bar differential pressure
  • Data logger for up to 100 million measured values
  • Adjustable alarm limits
  • Touch LC display
  • Smart features:
  • Prediction of the final dew point value
  • Camera function
  • PDF report function in accordance with ISO 8573-1
HVAC Meter PCE-VE 260HT
£ 4,566.00
Price excl. VAT &. delivery
Topseller
The HVAC meter offers an advanced solution for visual inspection in extreme environments with temperatures of up to 300 °C. With a specially developed high-temperature camera cable, it enables reliable image and video recording even under extreme conditions. The integrated connection on the camera cable for air cooling ensures effective cooling during use.

  • High-temperature camera cable up to 300 °C
  • Length of camera probe: 2 m
  • Diameter of camera probe: 6 mm
  • Connection for air cooling
  • 4-way camera head
  • Illumination via LED fibre optics
  • HDMI image transmission
  • 32 GB micro SD card memory
HVAC Meter PCE-VE 270HRS
£ 4,346.00
Price excl. VAT &. delivery

The HVAC meter gives you new, visual insights into the interior of motors and systems. The HVAC meter is the ideal tool for maintenance and repair in workshops or industrial companies. Optical analysis with an videoscope has never been so easy.

  • Cable length:  1000 mm, 3.28 ft
  • Cable diameter:  2.1 mm, 0.08"
  • 0° viewing angle
  • Camera resolution / image sensor: 400 x 400 Px
  • Cable type: flexible
  • Video output: HDMI
  • LED light

Humidity Detector PCE-UX 3031D
£ 4,241.00
Price excl. VAT &. delivery
Our Humidity Detector is a high-precision device that has been specially Good Laboratory Practice plaster analysis. With a maximum weighing capacity of 220 g and a measuring resolution of 0.001 g, it enables precise and reliable moisture measurements. The Humidity Detector works on the principle of drying with simultaneous weighing. During drying, the weight loss is continuously recorded and displayed as a percentage of the total mass.

  • weighing range: 0 ... 220 g
  • resolution: 0.001 g
  • absolute moisture: 0 ... 100 %
  • resolution: 0.01 %
  • heating temperature 1: 40 ... 180 °C
  • heating temperature 2: 105 ... 360 °C
  • % moisture
  • % dry matter
  • % moisture bd
  • g residual weight / kg
  • residual weight
  • data interface: RS232, USB, V24
  • GLP data management
  • Data Bridge software (optional)
  • with built-in printer
Force Gauge PCE-DDM 50
£ 3,913.00
Price excl. VAT &. delivery

The PCE-DDM 50 Force Gauge is the ideal tool for weighing big loads and for measuring strong tensile forces. The PCE-DDM 50 Force Gauge is delivered in a protective carrying case and includes two shackles made of heavy-duty steel. The instrument is manufacturer calibrated, but can be certified to ISO standards for an additional fee.


  • Measurement range: 50,000 kg / 500 kN / 110,231 lbs
  • Resolution: 20 kg / 200 N
  • Units of measurement: kg / t / lbs / N / kN
  • Supplied with remote control indicator

Humidity Detector PCE-UX 3031D-ICA incl. ISO-Calibration Certificate
£ 4,357.00
Price excl. VAT &. delivery
ISO Calibration
Our Humidity Detector is a high-precision device that has been specially developed for plaster analysis. With a maximum weighing capacity of 220 g and a measuring resolution of 0.001 g, it enables precise and reliable moisture measurements. The Humidity Detector works on the principle of drying with simultaneous weighing. During drying, the weight loss is continuously recorded and displayed as a percentage of the total mass.

  • Weighing range: 0 ... 220 g
  • Resolution: 0.001 g
  • Absolute moisture: 0 ... 100 %
  • Resolution: 0.01 %
  • Heating temperature 1: 40 ... 180 °C
  • Heating temperature 2: 105 ... 360 °C
  • % moisture
  • % dry matter
  • % moisture ATRO
  • g Residual weight / kg
  • Residual weight
  • Data interface: RS232, USB, V24
  • GLP data management
  • Data Bridge software (optional)
  • with built-in printer
  • incl. ISO-Calibration Certificate
Humidity Detector PCE-UX 3031
£ 3,819.00
Price excl. VAT &. delivery
Our Humidity Detector is a high-precision device that has been specially Good Laboratory Practice plaster / gypsum analysis. With a maximum weighing capacity of 220 g and a measuring resolution of 0.001 g, it enables exact and reliable moisture measurements. The Humidity Detector works on the principle of drying with simultaneous weighing. During drying, the weight loss is continuously recorded and displayed as a percentage of the total mass.

  • weighing range: 0 ... 220 g
  • resolution: 0.001 g
  • absolute moisture: 0 ... 100 %
  • resolution: 0.01 %
  • heating temperature 1: 40 ... 180 °C
  • heating temperature 2: 105 ... 360 °C
  • % moisture
  • % dry matter
  • % moisture bd
  • g residual weight / kg
  • residual weight
  • data interface: RS232, USB, V24
  • GLP data management
  • Data Bridge software (optional)