2 year Warranty
The DIN-Rail Measuring Instrument PCE-SM1 is suitable for making analog signals bus-capable. Various analog signals such as 0 ... 20 mA, 0 ... 10 V, PT100 etc. are converted from the analog input module to RS485 Modbus.
- Input channels: 2
- Inputs: PT100, 0/4 ... 20 mA, 0 ... 10 V, 0 ... 40 Ω
- Interface: RS485 Modbus (ASCII RTU)
- Power supply: 85 ... 253 V / 20 ... 50 V AC / DC (selectable)
The PCE-SM3 DIN rail measuring instrument is suitable for making binary signals or pulse signals bus-capable. It is thus possible, for example, to convert signals from flow sensors, rotary encoders, etc. to RS485 Modbus.
- Input channels: 2
- Inputs: pulse input / binary input
- Interface: RS485 Modbus (ASCII RTU)
- Power supply: 85 ... 253 V / 20 ... 50 V AC/DC (selectable)
The PCE-HT 71N Data Logger detects air temperature and humidity and stores readings in its internal memory. The Data Logger has a compact format and a wide memory capacity (up to 32,000 values / 16,000 values for each parameter) and it is mainly used as a Data Logger in fields such as supermarket refrigeration units, refrigerated transport, warehouses, and other temperature controlled environments.
- Measurement range: 0 ... 100% RH / -35 ... 70°C / -31 ... 158°F
- Accuracy: ± 3% RH (20 ... 80%) and ± 5% / ± 1°C (1.8°F)
- Resolution: 0.5% RH / 0.1°C (0.18°F)
- Memory: Max. 32,000 measurement data (16,000 for each parameter (humidity / temperature))
- Input channels: 8
- Inputs: binary input
- Interface: RS485 Modbus (ASCII RTU)
- Power supply: 85 ... 253 V / 20 ... 50 V AC/DC (selectable)
The data logger for temperature and humidity detects air temperature and humidity and stores readings in its internal memory. The data logger for temperature and humidity has a compact format and a wide memory capacity (up to 32,000 values / 16,000 values for each parameter) and it is mainly used as a data logger in fields such as supermarket refrigeration units, refrigerated transport, warehouses, and other temperature controlled environments.
- Measurement range: 0 ... 100% RH / -35 ... 70°C / -31 ... 158°F
- Accuracy: ± 3% RH (20 ... 80%) and ± 5% / ± 1°C (1.8°F)
- Resolution: 0.5% RH / 0.1°C (0.18°F)
- Memory: Max. 32,000 measurement data (16,000 for each parameter (humidity / temperature))
The colorimeter PCE-CSM 10 was developed for quality control, offers a high accuracy and comes with a 3.5" touch screen display. You can choose between different color spaces like CIE L*A*B, XYZ, Yxy, LCh, LUV, LCH, LAB &WI &YI, Color Fastness, and Staining Fastness. 400 to 700 nm photodiode array for 10 nm wavelength increments with Reflectance Curve graph.
- CIE L*A*B/LCh, CIE XYZ/Yxy, CIE LUV/LCH, LAB &WI &YI, Color Fastness, and Color Staining
- Measuring geometry 10° or 2°/d
- Black and white calibration
- Opacity, 18 light source options, metameric index, CIE 1976/1994/2000
- 1000 Standards, 15,000 sample memory
The PCE-830 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This Current Clamp also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.2 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate
The PCE-830 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Current Clamp also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The PCE-830-2 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This Current Clamp also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.1 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
The PCE-830-3 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This Current Clamp also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The PCE-830 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This Current Clamp also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm / 1.1 in diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 mm x 62 mm x 36 mm / 8.2 in x 2.4 in x 1.4 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
The PCE-830-3 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This Current Clamp also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-3007 flexible amp clamp (3000 A)
- Electrical conductor pick-up: 170 mm / 6.69 in diameter
- Length of electrical conductor: 610 mm / 24.0 in
- Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values - single phase)