The Ultrasonic testing device has a measuring range of ±32 m/s. To perform flow measurement with the Ultrasonic testing device, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.
Measuring range: ±32 m/s
Resolution: 0.001 m/s
Sensor for pipe diameter: DN 15 … 100 / 20 … 108 mm
Sensor dimensions: 45 x 30 x 30 mm
Temperature resistance from -30 … 160 °C
for different media
for different pipe materials
Measuring parameters: flow velocity, volume flow and volume
Interface: USB
Data logger: 32 GB memory capacity (10 million measuring points)
The ultrasonic flow meter has a measuring range of ±32 m/s. To perform flow measurement with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.
Measuring range: ±32 m/s
Resolution: 0.001 m/s
incl. 4 sensors
Pipe size: DN 50 … 700 / 57 … 720 mm, DN 15 … 100 / 20 … 108 mm
Temperature resistance: -30 … 160 °C
for different media
for different pipe materials
Measuring parameters: Flow velocity, volume flow and volume
The Portable Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the Portable Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.
Measuring range: ±32 m/s
Resolution: 0.001 m/s
incl. 4 sensors
Sensor for pipe diameters: DN 50 … 700 / 57 … 720 mm, DN 15 … 100 / 20 … 108 mm
Temperature resistance: -30 … 160 °C
for different media
for different pipe materials
Measuring parameters: Flow velocity, volume flow and volume
The Portable Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the Portable Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.
Measuring range: ±32 m/s
Resolution: 0.001 m/s
Pipe size: DN 50 … 700 / 57 … 720 mm
Temperature resistance: -30 … 160 °C
for different media
for different pipe materials
Measuring parameters: Flow velocity, flow rate and volume
The BTU Meter / Clamp on Heat meterhas a measuring range of ±32 m/s. To perform flow measurement with the Portable Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.
The ultrasonic HVAC meter is a fixed installation meter. The flow rate of liquids in pipes can be determined with this HVAC meter. The sensors from the ultrasonic HVAC meter can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.
The ultrasonic flow meter is a fixed installation meter. The flow rate of liquids in pipes can be determined with this flow meter. The sensors from the ultrasonic flow meter can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.
The Ultrasonic testing device is a fixed installation meter. The flow rate of liquids in pipes can be determined with this Ultrasonic testing device. The sensors from the Ultrasonic testing device can be mounted directly on the pipes to be measured without having to cut them open.
The Portable Ultrasonic Flow Meter is a fixed installation meter. The flow rate of liquids in pipes can be determined with this flow meter. The sensors from the Portable Ultrasonic Flow Meter can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.
The ultrasonic flow meter is a fixed installation meter. The flow rate of liquids in pipes can be determined with this flow meter. The sensors from the ultrasonic flow meter can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.
The ultrasonic flow tester is a fixed installation meter. The flow rate of liquids in pipes can be determined with this ultrasonic flow tester. The sensors from the ultrasonic flow tester can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.
The ultrasonic flow meter is a fixed installation meter. The flow rate of liquids in pipes can be determined with this flow meter. The sensors from the ultrasonic flow meter can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.
The ultrasonic flow meter is a fixed installation meter. The flow rate of liquids in pipes can be determined with this flow meter. The sensors from the ultrasonic flow meter can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.
The Ultrasonic testing device is a fixed installation meter. The flow rate of liquids in pipes can be determined with this flow tester. The sensors from the Ultrasonic testing device can be mounted directly on the pipes to be measured without having to cut them open.