2 year Warranty
PCE-5000 is a portable hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in Non-destructive testing produces microscopic indentation.
- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available
The Class 1 outdoor sound level meter PCE-430-EKIT-ICA with integrated data logger meets all requirements for noise measurement and frequency analysis. This integrated precision pulse outdoor sound level meter kit follows all valid standards and guidelines, and is designed for use outdoors in all weather. Typical applications are the measurement of workplace noise, compliance, environmental noise detection, selection of hearing protector selection, selection of appropriate noise abatement measures and noise exposure estimation.
- Accuracy class 1
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- Incl. ISO calibration certificate
For industrial continuous production of wood pellets, chips, sawdust and similar materials when on-line moisture measurement for monitoring and controlling the drying and mixing process is important. Consistent quality of every batch, reduction of the consumption of materials, and shortest possible drying and mixing times are the criteria which are important in materials production. The PCE-MWM 300P moisture test sensor of PCE Instruments helps meet those criteria through highly accurate moisture measurement.
- Measuring range: 0 ... 100%
- The maximum permissible error (absolute): Lab analysis of your sample determines % error
- Temperature range: -40 ... +150 °C (-40 ... +302 °F)
- Current consumption: 200 mA
- Power supply : 24 (18 ... 36) VDC
- Questionnaire starts evaluation process
- Application: pellets, wood chips
The environmental meter PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The environmental meter is equipped with an octave band frequency filter. Optionally, the environmental meter can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with an environmental meter over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate
The Class 1 outdoor road noise / traffic noise meter PCE-430-EKIT-ICA with integrated data logger meets all requirements for noise measurement and frequency analysis. This integrated precision pulse outdoor road noise / traffic noise meter kit follows all valid standards and guidelines, and is designed for use outdoors in all weather. Typical applications are the measurement of workplace noise, compliance, environmental noise detection, selection of hearing protector selection, selection of appropriate noise abatement measures and noise exposure estimation.
- Accuracy class 1
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- Incl. ISO calibration certificate
PCE-FD 20 is a portable Wall Thickness Meter or ultrasonic thickness gauge with a large LCD screen that displays A-scan maps of ultrasonic signals as well as B-scan cross sections. Ideal for use in mechanical engineering, aerospace and metallurgical applications, this high-frequency ultrasound-based Wall Thickness Meter uses a contact transducer (two different probes included; 45° and 90°) to measure material thickness and identify flaws and defects such as discontinuity in welds.
- Operating frequency range: 1 ... 10 MHz
- Measured time interval range: 6 ... 1000 microseconds (µs)
- Sound velocity: 1000 ... 9999 m/s
The PCE-VM 40C Condition monitoring vibration meter with SMS alert functionality was designed for vibration and shock metering on buildings, bridges, towers, and other artificial structures. The condition monitoring vibration meter measures vibrations in accordance to DIN 4150-3, BS 7385 and SN 640312A standards. With its internal memory for up to 100,000 readings, the PCE-VM 40C Condition monitoring vibration meter can determine the effects of construction sites, traffic, or industrial processing on buildings over a long period of time.
- Triaxial acceleration meter
- In accordance with BS 7385 standard
- Quad band GSM (optional)
- SMS alarm notifications (optional)
- Memory size of 100,000 values (SD card)
- Integrated NiMH battery
- FFT analysis, XYZ and vector sum display