2 year Warranty
This wind measurer station with outside sensor is a real all-rounder. The wireless wind measurer station with outside sensor is easy to assemble based on the instructions provided. You do not have to be a professional to operate the wireless wind measurer station and outside sensors. The weather data of the wind measurer station with outside sensor for different parameters are sent up to 100 meters by radio signal to the main station.
- 2 displays
- Indoor temperature in Celsius or Fahrenheit
- Outside temperature in Celsius or Fahrenheit
- Indoor air humidity / outdoor air humidity
- Air pressure gauge in inHg or hPa
- Absolute or relative air pressure display selectable
- Precipitation indication in mm or inch
- Precipitation indicator for 1 hour, 24 hours, 1 week, 1 month
- Wind speed in mph, km / h, m / s, knots ...
- Wind direction indicator
- Wind chill temperature gauge
- Weather forecast, trend indicator, storm warning
- and much more...
The PCE-830 Portable Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This Portable Power Analyzer also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm / 1.1 in diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 mm x 62 mm x 36 mm / 8.2 in x 2.4 in x 1.4 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
PCE-WSB 1 is a portable handheld battery-powered surface testing - brightness / whiteness color meter used to measure the brightness level of paper, cardboard, cellulose, pulp, textiles, paint, enamel, plastic, porcelain, cement, concrete, building materials, chemicals, powders, talc, starch, flour, salt, detergents, cosmetics and other non-metal substances.
- Measures the whiteness degree of blue light (Wb = R457)
- Meets ISO 2470 and ISO 3688 standards
- Compact, lightweight and user-friendly
- Resolution: 0.1
- Repeat accuracy : ±0.1
PCE-432 is a class 1 data-logging decibel meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter is equipped with GPS functionality, allowing measured values to be assigned to an exact geographic location.
- Measuring range: 22 ... 136 db(A)
- A, B, C and Z frequency weightings
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
PCE-432 is a class 1 data-logging sound pressure level (SPL) meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter is equipped with GPS functionality, allowing measured values to be assigned to an exact geographic location.
- Measuring range: 22 ... 136 db(A)
- A, B, C and Z frequency weightings
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
PCE-PST 1 adhesion tester is designed to check the adhesive force of edges and edge bands on support materials. With the adhesion tester, checks can be made with respect to the quality of workmanship. Feed speed, travel distance, tension, and traction angle are fixed. Ball transfer units on the guide surface of the Test Stand reduce the coefficient of friction. Likewise the self-locking jaws and smooth guide rollers always guarantee reproducible and comparable results.
- Measuring range: 500 N / 50 kg / 110 lbs
- Measurable edge thickness: 0.4 mm ... 3.5 mm
- Measurable thicknesses: 10 mm ... 64 mm
- Velocity: 0.3 m / min
PCE-432 is a class 1 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter is equipped with GPS functionality, allowing measured values to be assigned to a precise geographic location. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 22 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- GPS receiver for location determination
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
The HVACR Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase HVACR Tester also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
PCE-432-ICA is a class 1 data logging noise meter / sound meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy noise meter / sound meter is equipped with GPS functionality, allowing measured values to be assigned to a precise geographic location. The noise meter / sound meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 22 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- GPS receiver for location determination
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
The Ozone Meter Xgard-1-O3 is a single-gas gas sensor used to warn for gases (Ozone, O3, 0 ... 1 ppm), with display and signal output for sensors in combination with a stationary instrument to detect gases (ATEX or UL approval).
- Stationary
- For (Ozone, O3, 0 ... 1 ppm)
- Additional display and alarm station
- ATEX or UL approval
PCE-432 is a class 1 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter is equipped with GPS functionality, allowing measured values to be assigned to a precise geographic location. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 22 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- GPS receiver for location determination
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
PCE-ATP 1 is an ATP meter, tester, lumitester or luminometer used for surface testing. This luminometer allows for quick and easy first-generation adenosine triphosphate (ATP) testing and monitoring to ensure proper cleanliness, sterilization and sanitization. PCE-ATP 1 is an ATP tester that can be used for cleanliness control and documentation in many different applications.
- Measurement range: 0 ... 999,999 relative light units (RLUs)
- Stores up to 10,000 date- and time-stamped data records to internal memory
- Enables rapid detection of bacterial or microbial residue