2 year Warranty
PCE-FD 20 is a portable ultrasonic thickness gauges or ultrasonic wall thickness gauges with a large LCD screen that displays A-scan maps of ultrasonic signals as well as B-scan cross sections. Ideal for use in mechanical engineering, aerospace and metallurgical applications, this high-frequency ultrasound-based ultrasonic thickness gauges uses a contact transducer (two different probes included; 45° and 90°) to measure material thickness and identify flaws and defects such as discontinuity in welds.
- Operating frequency range: 1 ... 10 MHz
- Measured time interval range: 6 ... 1000 microseconds (µs)
- Sound velocity: 1000 ... 9999 m/s
The PCE-TG 300-NO5/90 is a paint thickness tester for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the paint thickness tester. Wall thicknesses under a coating can also be measured with the paint thickness tester.
- Measuring range: 1 ... 600 mm / 0.039 ... 23.62" (steel)
- Diameter: 10mm / 0.39"
- Sensor at 90° angle
- Minimum diameter of pipes: 20 x 3 mm / 0.787 ... 0.118"
- Frequency: 5 MHz
- Bluetooth
- incl. ISO calibration certificate
The PCE-TG 300-NO5/90 is a thickness meter for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the thickness meter. Wall thicknesses under a coating can also be measured with the thickness meter.
- Measuring range: 1 ... 600 mm / 0.039 ... 23.62" (steel)
- Diameter: 10mm / 0.39"
- Sensor at 90° angle
- Minimum diameter of pipes: 20 x 3 mm / 0.787 ... 0.118"
- Frequency: 5 MHz
- Bluetooth
PCE-5000 is a portable hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Non-destructive testing produces microscopic indentation.
- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available
The PCE-TG 300-NO5/90 is a thickness gauge for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the thickness gauge. Wall thicknesses under a coating can also be measured with the thickness gauge.
- Measuring range: 1 ... 600 mm / 0.039 ... 23.62" (steel)
- Diameter: 10mm / 0.39"
- Sensor at 90° angle
- Minimum diameter of pipes: 20 x 3 mm / 0.787 ... 0.118"
- Frequency: 5 MHz
- Bluetooth