2 year Warranty
The PCE-313A Humidity/Temp Data Logger measures relative humidity and temperature and can be used in the air-conditioning sector. The PCE-313A Humidity/Temp Data Logger can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe. The internal memory of this test equipment allows the Humidity/Temp Data Logger to record humidity and temperature data at an adjustable measurement interval. Thanks to its SD memory card (1 to 16 GB) the humidity test instrument can be used for long term data acquisition.
The easy-to-use PCE-PA 8300 HVAC Meter is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:
- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 2) 30 A ... 3000 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage
The PCE-313 A Data Logger measures relative humidity and temperature and can be used in the air-conditioning sector. The PCE-313 A Data Logger can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe. The internal memory of this test equipment allows the Data Logger to record humidity and temperature data at an adjustable measurement interval. Thanks to its SD memory card (1 to 16 GB) the humidity test instrument can be used for long term data acquisition. The logging meter comes manufacturer calibrated (ISO calibration certificate as an option).
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.5 ... 120°F
- Wet bulb temperature: -21 ... 50°C / -5.8 ... 122°F
- Memory: SD card (1 ... 16 GB)
For industrial continuous production of wood pellets, chips, sawdust and similar materials when on-line moisture measurement for monitoring and controlling the drying and mixing process is important. Consistent quality of every batch, reduction of the consumption of materials, and shortest possible drying and mixing times are the criteria which are important in materials production. The PCE-MWM 300P moisture test sensor of PCE Instruments helps meet those criteria through highly accurate moisture measurement.
- Measuring range: 0 ... 100%
- The maximum permissible error (absolute): Lab analysis of your sample determines % error
- Temperature range: -40 ... +150 °C (-40 ... +302 °F)
- Current consumption: 200 mA
- Power supply : 24 (18 ... 36) VDC
- Questionnaire starts evaluation process
- Application: pellets, wood chips
The PCE-830 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The data logger for temperature and humidity measures relative humidity and temperature and can be used in the air-conditioning sector. The data logger for temperature and humidity can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe. The internal memory of this test equipment allows the data logger to record humidity and temperature data at an adjustable measurement interval. Thanks to its SD memory card (1 to 16 GB) the humidity test instrument can be used for long term data acquisition.
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.5 ... 120°F
- Wet bulb temperature: -21 ... 50°C / -5.8 ... 122°F
- Memory: SD card (1 ... 16 GB)
- Incl. ISO Calibration Certificate
The PCE-830-3 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The data logger for temperature and humidity is a combination thermometer hygrometer used to measure the relative humidity (% RH) and temperature (°C / °F) of the air. Ideal for use in evaluating heating, ventilation and air conditioning (HVAC) system performance, this digital data logger for temperature and humidity also has a port for connecting a type-K thermocouple.
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.5 ... 120°F
- Wet bulb temperature: -21 ... 50°C / -5.8 ... 122°F
- Memory: SD card (1 ... 16 GB)
The PCE-830-2 HVAC Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This HVAC Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.1 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
The temperature data logger is a digital device with four input channels for type K and type J temperature sensors and two input channels for PT100 temperature sensors. The temperature data logger has a SD card slot (from 1 ... 16 GB) for storing the measured data. The data is stored in xls format on the SD card of the data logger so that no additional software is needed for further analysis. This temperature logging test instrument comes manufacturer calibrated. An ISO calibration certificate can be purchased as an optional accessory.
- 4 input channels for type-K, J temperature sensors
- 2 input channels for Pt100 temperature sensors
- 2 x type-K TF-500 temperature sensors are included in the package
- Sampling rate of 1 sec.
- SD card memory (1 ... 16 GB)
- Automatic range: 30 ... 130 dB
- Manual range: 30 ... 80 / 50 ... 100 / 80 ... 130 dB
- Resolution: 0.1 dB
- Accuracy: ±1.4 dB
- Memory capacity: 32700 values
- incl. software for LEQ calculation
Important! The LEQ value is only calculated by the software after the data transfer from the device to the PC or laptop.