2 year Warranty
The PCE-VA 20 is a versatile Digital Multimeter for determining environmental conditions such as wind, temperature and humidity. It is additionally used to test heating, ventilation and air conditioning / cooling (HVAC) systems. This triple thermometer-hygrometer-anemometer device has a 10 cm / 3.9" Ø fan impeller and a clear backlit LCD. Available functions include display hold, average / maximum / minimum value, auto shutdown, low-battery warning, and metric / imperial choice.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew
point temperature and wet-bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±
(3% of measured value + 0.3 m/s) when more than 20 m/s
- Resolution: 0.1
- Incl. ISO Calibration Certificate
The PCE-VA 20-SET is a multi-functional wind measurer including flow hoods for assessing and balancing heating, ventilation and air conditioning or cooling (HVAC) installations. This multi-faceted anemometer-thermometer-hygrometer incorporates a 10 cm / 3.9" diam. fan impeller, easy-to-view backlit LCD, and useful functions, e.g. display hold, average val, maximum val, minimum val, auto power-off, low battery indication, and imperial/metric option.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew
point temperature and wet-bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±(3% of
measured value + 0.3 m/s) when more than 20 m/s
- Resolution: 0.1°C / 0.18°F
- Includes 2 x capture hoods (1 x round 210 mm / 8.3 in Ø, 1 x square 346 x 346
mm / 13.6 x 13.6 in)
- incl. ISO Calibration Certificate
The PCE-313A Digital Thermometer measures relative humidity and temperature and can be used in the air-conditioning sector. The PCE-313A Digital Thermometer can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe. The internal memory of this test equipment allows the Digital Thermometer to record humidity and temperature data at an adjustable measurement interval. Thanks to its SD memory card (1 to 16 GB) the humidity test instrument can be used for long term data acquisition.
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.5 ... 120°F
- Wet bulb temperature: -21 ... 50°C / -5.8 ... 122°F
- Memory: SD card (1 ... 16 GB)
- Incl. ISO Calibration Certificate
With the Digital Thermometer PCE-IR 50, surface temperatures can measured quickly and easily. The measuring range of the digital thermometer is 0 ... 500 °C / 32 ... 932 °F. The measured temperature is output as a 4 ... 20-mA standard signal which means that the digital thermometer can be easily integrated into different monitoring systems, including those in different production processes or food storage as well as the monitoring of electronic systems.
- Measurement range: 0 ... 500 °C / 32 ... 932 °F
- Accuracy: ± 1.5 °C or ± 1 %
- Optical resolution: 15:1
- Output signal: 4 ... 20-mA standard signal
- For fixed installation (mounting bracket incl.)
PCE-VA 20-SET is a Digital Multimeter with capture hoods for assessing and balancing heating, ventilation and air conditioning or cooling (HVAC) systems. This combined hygrometer-anemometer-thermometer possesses a 10 cm / 3.9" diameter fan impeller and a bright backlit LCD. The functions of the device incorporate display hold, mean value, max value, min value, battery-saving auto shutdown, low-battery display, and a choice between metric and imperial units.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew
point temperature and wet-bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±(3% of
measured value + 0.3 m/s) when more than 20 m/s
- Resolution: 0.1°C / 0.18°F
- Includes 2 x capture hoods (1 x round 210 mm / 8.3 in Ø, 1 x square 346 x 346
mm / 13.6 x 13.6 in)
PCE-VA 20 is a Digital Multimeter for testing heating, ventilation and air conditioning or cooling (HVAC) systems. This combination anemometer-hygrometer-thermometer features a 10 cm / 3.9" Ø fan impeller, easy-to-read backlit LCD, and functions such as display hold, average value, maximum value, minimum value, battery-saving automatic power off, low-battery indicator, and metric or imperial unit selection.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew
point temperature and wet-bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±(3% of
measured value + 0.3 m/s) when more than 20 m/s
- Resolution: 0.1
With the Digital Thermometer PCE-IR 50-ICA, surface temperatures can measured quickly and easily. The measuring range of the digital thermometer is 0 ... 500 °C / 32 ... 932 °F. The measured temperature is output as a 4 ... 20-mA standard signal which means that the digital thermometer can be easily integrated into different monitoring systems, including those in different production processes or food storage as well as the monitoring of electronic systems.
- Measurement range: 0 ... 500 °C / 32 ... 932 °F
- Accuracy: ± 1.5 °C or ± 1 %
- Optical resolution: 15:1
- Output signal: 4 ... 20-mA standard signal
- For fixed installation (mounting bracket incl.)
- incl. ISO Calibration Certificate
With the PCE-890U-ICA digital thermometer, measurements of surface temperatures can be carried out quickly and easily. Since the digital thermometer uses infrared radiation for temperature measurement, no direct contact with the measuring object is required. The digital thermometer makes it easy to measure objects from a distance that are difficult to access.
- Measuring range: -50 ... 1150°C / -58 ... 2102°F
- Accuracy: ± 1.5% ± 2°C / 3.6°F (0 ... 500°C / 32 ... 932°F)
- Resolution: 0.1°C / 0.18°F (<1000°C)
- Emission level: 0.1 ... 1
- incl. ISO Calibration Certificate