2 year Warranty
PCE-428 is a class 2 data logging noise meter / sound meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy noise meter / sound meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The noise meter / sound meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
PCE-TDS 100HSH is a portable handheld clamp-on ultrasonic flow test instrument or meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 20 … 108 mm / approx. 3/4 in ... 4in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 15 … 700, 20 … 720 mm (approx. 3/4 … 28")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, (N,W)
- Incl. sensors TDS-M1 and TDS-S1
PCE-TDS 100HSH is a portable handheld clamp-on ultrasonic flow test instrument or meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 20 … 108 mm / approx. 3/4 in ... 4in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 15 … 700, 20 … 720 mm (approx. 3/4 … 28")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, (N,W)
- Incl. sensors TDS-M1 and TDS-S1
The 4-channel PCE-VM 5000 accelerometer performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the accelerometer is able to record vibrations at different points of the component to be tested.
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity and displacement
- Connection of up to 4 sensors simultaneously
- Data storage on SD card
- Including 2 additional sensors for vibration
The class 2 outdoor condition monitoring sound level meter PCE-428-EKIT, from the field of environmental measurement technology, is an optimal condition monitoring sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The outdoor condition monitoring sound level meter is equipped with an octave band frequency filter. Optionally, the outdoor sound level meter PCE-428-EKIT can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a sound level meter over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time
weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
PCE-432-ICA is a class 1 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter is equipped with GPS functionality, allowing measured values to be assigned to a precise geographic location. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 22 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- GPS receiver for location determination
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
PCE-TDS 100HSH-ICA is a portable handheld clamp-on ultrasonic flow meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 20 … 108 mm / approx. 3/4 in ... 4 in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 15 … 700, 20 … 720 mm
- Sensor temperature range: 32 ... 320°F
- Sensor installation: V, (N,W)
- Incl. sensors TDS-M1 and TDS-S1
- Incl. ISO Calibration Certificate
PCE-TDS 100HSH-ICA is a portable handheld clamp-on ultrasonic flow meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 20 … 108 mm / approx. 3/4 in ... 4in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 15 … 700, 20 … 720 mm (approx. 3/4 … 28")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, (N,W)
- Incl. sensors TDS-M1 and TDS-S1
- Incl. ISO Calibration Certificate
The 4-channel PCE-VM 5000 Vibration Analyzer performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration analyzer is able to record vibrations at different points of the component to be tested.
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity and displacement
- Connection of up to 4 sensors simultaneously
- Data storage on SD card
- Including 2 additional sensors for vibration
PCE-TDS 100HSH is a portable handheld clamp-on ultrasonic flow meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 20 … 108 mm / approx. 3/4 in ... 4in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 15 … 700, 20 … 720 mm
- Sensor temperature range: 32 ... 320°F
- Sensor installation: V, (N,W)
- incl. sensors TDS-M1 and TDS-S1
PCE-TDS 100HSH-ICA is a portable handheld clamp-on Clamp-on Ultrasonic Flow Meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 20 … 108 mm / approx. 3/4 in ... 4in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 15 … 700, 20 … 720 mm (approx. 3/4 … 28")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, (N,W)
- Incl. sensors TDS-M1 and TDS-S1
- Incl. ISO Calibration Certificate
PCE-TDS 100HSH-ICA is a portable handheld clamp-on ultrasonic HVAC meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 20 … 108 mm / approx. 3/4 in ... 4in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 15 … 700, 20 … 720 mm (approx. 3/4 … 28")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, (N,W)
- Incl. sensors TDS-M1 and TDS-S1
- Incl. ISO Calibration Certificate
The 4-channel PCE-VM 5000 vibration data logger performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration data logger is able to record vibrations at different points of the component to be tested.
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity and displacement
- Connection of up to 4 sensors simultaneously
- Data storage on SD card
- Including 2 additional sensors for vibration