2 year Warranty
The data logger for temperature and humidity precisely measures air temperature and relative humidity. This accurate and reliable device shows the current measurements on the large LCD display and saves the measurement data directly to an SD card (included). The data logger for temperature and humidity is equipped with two channels, accommodates an SD card memory of up to 16 GB, offers an adjustable measurement rate / sampling interval, and includes a wall mount, making the device ideal for logging data over an extended period of time.
- Measurement ranges: 0 … 50°C / 32 ... 122°F, 10 ... 90% RH
- Resolution: 0.1°C / 0.18°F, 0.1% RH
- Data format: .XLS (compatible with Microsoft Excel)
- Set = Quantity of 5 x units
The data logger PCE-PDA 1000L measures the relative pressure on machines and systems. The relative pressure is measured by this data logger in the range between -100 ... 2000 kPa. The data logger PCE-PDA 1000L has a quick coupling connection with which the air pressure or water pressure can be directly applied to the device.
- Measuring range pressure: -100 ... 2000 kPa relative / -14.5 ... 290 PSI
- Resolution: 0.01 kPa, 0.1 kPa
- Accuracy: <± 0.5% of the measuring range
- USB interface
- Data logger
- Adjustable measuring units: Pa, hPa, kPa, MPa, mbar, bar, ATM, kg / cm², mmH2O, cmH2O, inH2O, mmHg, inHg, Torr, PSI, PSF
The power data logger (Graphic Power Quality Analyzer) PCE-GPA 62 is used for single-phase or three-phase measurements of the active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics.
- Real-time test, register and measurement of voltage and current (real and effective)
- Measures power factor and phase angle, frequency, energy, active, reactive and apparent power
(single-phase or three-phase in symmetrical networks).
- Max. conductor diameter: 55 mm / 2.2 in
- Records up to 50,000 records
PCE-VDR 10 is a single-axis accelerometer or vibration data logger monitor with real-time measurement and data logging capabilities. This vibration data logger records acceleration (m/s, g, ft/s) as well as velocity (mm/s, cm/s, in/s) measurements and saves the measured data to an included SD card memory. There is also an analog output, which makes this vibration data logger compatlble with control systems.
- Acceleration measuring range:
0.5 ... 199.9 m/s, 0.05 ... 20.39 g, 2 ... 656 ft/s
- Velocity measuring ranges:
0.5 ... 199.9 mm/s, 0.05 ... 19.99 cm/s, 0.02 ... 7.87 in/s
- Frequency range: 10 ... 1000 Hz
- Analog output: 4 ... 20 mA
- RS-232 and USB interface
PCE-428 is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level data logger has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
PCE-VDR 10 is a single-axis accelerometer or shock data logger with real-time measurement and data logging capabilities. This single-axis shock data logger records acceleration (m/s, g, ft/s) as well as velocity (mm/s, cm/s, in/s) measurements and saves the measured data to an included SD card memory. There is also an analog output, which makes this shock data logger compatlble with control systems.
- Single-axis Acceleration measuring range:
0.5 ... 199.9 m/s, 0.05 ... 20.39 g, 2 ... 656 ft/s
- Velocity measuring ranges:
0.5 ... 199.9 mm/s, 0.05 ... 19.99 cm/s, 0.02 ... 7.87 in/s
- Frequency range: 10 ... 1000 Hz
- Analog output: 4 ... 20 mA
- RS-232 and USB interface
The dB data logger is used to determine volume. The PCE-NDL 10 dB data logger is a handy measuring device that meets the highest requirements. In order to evaluate the measured data in the best possible way, it is possible to use the internal measurement data memory on the noise dosimeter. In addition, the dB data logger has an SD card slot that enables the use of an SD card as an additional storage medium.
- Measuring range: SPL: Auto 30 ... 130 dB
- Resolution: 0.1 dB
- Low sampling rate
- Automatic or manual storage
- Selectable storage interval
- Backlit LC display
- Dose measurement or SPL measurement