2 year Warranty
The tabletop scale PCE-MA 100 allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the benchtop scale dries the material to be weighed, and then calculates the moisture content from the weight difference.
- Testing or weighing capacity: 110 g / 3.88 oz
- Readability: 1 mg / 0.001 g / 0.01 %
- Adjustable drying temperature and time
PCE-MA 110 is a benchtop scale or halogen moisture analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the moisture analyzer can be performed at any time using the automatic calibration function and the included 100 g weight.
- Weighing range: 0.01 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.1 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
PCE-MA 110 is a tabletop scale or halogen moisture analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the moisture analyzer can be performed at any time using the automatic calibration function and the included 100 g weight.
- Weighing range: 0.01 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.1 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
PCE-MA 110 is a LAB scale or halogen moisture analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the moisture analyzer can be performed at any time using the automatic calibration function and the included 100 g weight.
- Weighing range: 0.01 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.1 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
The PCE-MA 202 is an oven-drying tabletop scale for weighing and heating material samples to determine moisture content. The heating chamber warms up to 199 °C / 390 °F with the use of halogen lamps. Drying of the sample to be weighed takes place within the chamber of the tabletop scale and the moisture content is subsequently calculated from the difference between the initial and final weight.
- Testing or weighing capacity: 200 g / 7.05 oz
- Readability: 10 mg / 0.01 g / 0.1%
- Adjustable drying temperature and time
The LAB Scale PCE-MA 202 is an oven-drying laboratory balance for weighing and heating material samples to determine moisture content. The heating chamber warms up to 199 °C / 390 °F with the use of halogen lamps. Drying of the sample to be weighed takes place within the chamber of the laboratory balance and the moisture content is subsequently calculated from the difference between the initial and final weight.
- Testing or weighing capacity: 200 g / 7.05 oz
- Readability: 10 mg / 0.01 g / 0.1%
- Adjustable drying temperature and time
PCE-MA 110 is a benchtop scale or halogen moisture analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the moisture analyzer can be performed at any time using the automatic calibration function and the included 100 g weight.
- Weighing range: 0.01 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.1 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
- Incl. ISO calibration certificate
PCE-MA 110 is a tabletop scale or halogen moisture analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the moisture analyzer can be performed at any time using the automatic calibration function and the included 100 g weight.
- Weighing range: 0.01 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.1 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
- Incl. ISO calibration certificate
Suitable for determining the humidity of bulk substances, this moisture test instrument can be fitted into containers and systems such as troughs,
bunkers, distributors, augers, conveyors, bins and silos. This permits
24/7 moisture measurement of fibrous materials, sawdust, gravel, fly ash
(mineral), wood chips (surface to 5 cm) feed grain, flour, pastes,
seed, or similar bulk or flowing substances. These test instruments / test sensors are mainly for use in manufacturing processes to give the opportunity of process optimization to the manufacturer or to insure the moisture content of the final product.
- PCE-MWM 240-B Rod sensor (custom length 500 ... 1500 mm)
- Lab analysis of your sample determines % error
- Measuring range: 0 ... 100%
- Material temperature range: -0 ... +80 °C (+41 ... +176 °F)
- Analog and digital signal output
The Benchtop Scale PCE-MA 100-ICA allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the Benchtop Scale dries the material to be weighed, and then calculates the moisture content from the weight difference.
- Testing or weighing capacity: 110 g / 3.88 oz
- Readability: 1 mg / 0.001 g / 0.01 %
- Adjustable drying temperature and time
- incl. ISO Calibration Certificate
PCE-MA 110 is a LAB scale or halogen moisture analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the moisture analyzer can be performed at any time using the automatic calibration function and the included 100 g weight.
- Weighing range: 0.01 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.1 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
- Incl. ISO calibration certificate