2 year Warranty
The PCE-DDD 10 shore hardness tester is an ergonomic device to check Shore D hardness in materials such as hard rubber and thermoplastic. It has been designed with a very high quality.
- Handheld device
- For Shore D measurements
- Single and Serial measurements
- Data transfer to PC
- Incl. ISO Calibration Certificate
The Material Hardness Tester for Metal PCE-2600N-ICA is used wherever a fast hardness test has to be carried out.
It is possible to use the material tester PCE-2600N-ICA to determine the surface hardness of many metals.
The material tester PCE-2600N-ICA is especially suitable for quality or product inspection.
- Measurement according to Leeb Rebound method
- Measurement units: HLD, HRA, HRB, HRC, HB, HV, HS
- Measurement ranges: 170-960 HLD, 59.1-88 HRA, 3.5-101.7 HRB, 17.9-69.5 HRC, 19-683 HB, 80-1042 HV, 30.6-102.6 HS
- Accuracy: ± 0.5%, Repeatability: ± 0.8%
- Impactor: DL
- Display: 128 x 64 OLED
- Includes ISO calibration certificate
PCE-PST 1 adhesion tester is designed to check the adhesive force of edges and edge bands on support materials. With the adhesion tester, checks can be made with respect to the quality of workmanship. Feed speed, travel distance, tension, and traction angle are fixed. Ball transfer units on the guide surface of the Test Stand reduce the coefficient of friction. Likewise the self-locking jaws and smooth guide rollers always guarantee reproducible and comparable results.
- Measuring range: 500 N / 50 kg / 110 lbs
- Measurable edge thickness: 0.4 mm ... 3.5 mm
- Measurable thicknesses: 10 mm ... 64 mm
- Velocity: 0.3 m / min
PCE-950 is a handheld material hardness tester used to determine the hardness of 10 different types of metal (i.e., cast steel, hammered steel, cold-rolled steel, stainless steel, cast iron, ductile iron, aluminum alloy, brass, bronze and forged copper alloy) according to the Leeb rebound method. In addition to Leeb hardness units, the metal hardness tester displays hardness measurements in Rockwell C, Rockwell B, Rockwell A, Brinell, Vickers and Shore hardness units.
- Measurement ranges: 19.8-68.5 HRC / 13.5-101.7 HRB / 59.1-85.8 HRA / 19-655 HB / 80-976 HV / 32.2-115 HS
- Hardness units: HL, HRC, HRB, HRA, HB, HV, HS
- Accuracy: ± 2% / Repeatability: ± 2%
- Impact device: Type D (integrated)
- Data Analysis Software
- For use with hammered steel, cold-rolled steel, stainless steel, cast iron, ductile iron, aluminum alloy, brass, bronze and forged copper alloy metals
Designed specifically for use in humidity measurement of bulk materials, this humidity sensor is installed in bins, silos, troughs, bunkers case, distributors, augers and conveyors. Material in bulk or flowing mass, such as fibrous materials, gravel, sawdust, fly ash (mineral), wood chips (surface to 5 cm) feed grain, flour, seed, pastes, ... is continuously measurable.
The Ultrasonic Contact Impedance (UCI) durometer PCE-3500 has been designed for the non-destructive hardness measurement of metallic components. A 136° Vickers diamond at the probe is stimulated with its self-resonance to allow the user to very accurately measure hardness of small items, thin-walled items (>1 mm), and surface-hardened layers. Small imprint after measuring for mirrored surfaces and nitrided surfaces.
- Probe is 98 Newtons / 22 lbf force, 10 and 50 N probes are options
- Tests HRC, HRB, HV, HB, MPa
- Memory function via SD card and included PC software
- Large color LCD display with back lighting
The Ultrasonic Contact Impedance (UCI) durometer PCE-3500 has been designed for the non-destructive hardness measurement of metallic components. A 136° Vickers diamond at the probe is stimulated with its self-resonance to allow the user to very accurately measure hardness of small items, thin-walled items (>1 mm), and surface-hardened layers. Small imprint after measuring for mirrored surfaces and nitrided surfaces.
- Probe is 10 Newtons / 2.2 lbf force, 50 and 98 N probes are options
- Tests HRC, HRB, HV, HB, MPa
- Memory function via SD card and included PC software
- Large color LCD display with back lighting
The environmental tester PCE-428-EKIT, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The environmental tester is a class 2 device and is equipped with an octave band frequency filter. Optionally, the environmental tester PCE-428-EKIT can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a SPL meter over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time
weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
PCE-950-ICA is a handheld metal hardness tester used to determine the hardness of 10 different types of metal (i.e., cast steel, hammered steel, cold-rolled steel, stainless steel, cast iron, ductile iron, aluminum alloy, brass, bronze and forged copper alloy) according to the Leeb rebound method. In addition to Leeb hardness units, the metal hardness tester displays hardness measurements in Rockwell C, Rockwell B, Rockwell A, Brinell, Vickers and Shore hardness units.
- Measurement ranges: 19.8-68.5 HRC / 13.5-101.7 HRB / 59.1-85.8 HRA / 19-655 HB / 80-976 HV / 32.2-115 HS
- Hardness units: HL, HRC, HRB, HRA, HB, HV, HS
- Accuracy: 2% / Repeatability: 2%
- Impact device: Type D (integrated)
- Data Analysis Software
- For use with hammered steel, cold-rolled steel, stainless steel, cast iron, ductile iron, aluminum alloy, brass, bronze and forged copper alloy metals
-
Includes ISO calibration certificate
The Ultrasonic Contact Impedance (UCI) durometer PCE-3500 has been designed for the non-destructive hardness measurement of metallic components. A 136° Vickers diamond at the probe is stimulated with its self-resonance to allow the user to very accurately measure hardness of small items, thin-walled items (>1 mm), and surface-hardened layers. Small imprint after measuring for mirrored surfaces and nitrided surfaces.
- 98 Newtons UCI probe / 22 lbf force, 10 and 50 N probes are options
- Tests HRC, HRB, HV, HB, MPa
- Memory function via SD card and included PC software
- Large color LCD display with back lighting
The PCE-DD-A hardness tester is used to measure Shore A hardness in soft gums, rubber, elastomers and more. Calibration is not available for this item.
- Measurement area: 0 ... 100 Shore A
PCE-CPT 20 is a Adhesion Tester, or surface coating flexibility testing device, used for testing the formability, ductility, adhesion and elongation of paints, lacquers, varnishes, powder and protective coatings on sheet metal. Used in manufacturing production, paint shop and quality control applications, the Adhesion Tester aids in determining coating strength, durability and elasticity.
- Tests surface coatings on metal sheets 0.3 to 1.25 mm thick
- Provides a maximum depression force of 2500 N
- Offers a display resolution of 0.01 mm
PCE-PST 1 Edge Band Tester is designed to check the adhesive force of edges and edge bands on support materials. With the edge band tester, checks can be made with respect to the quality of workmanship. Feed speed, travel distance, tension, and traction angle are fixed. Ball transfer units on the guide surface of the Test Stand reduce the coefficient of friction. Likewise the self-locking jaws and smooth guide rollers always guarantee reproducible and comparable results.
- Measuring range: 500 N / 50 kg / 110 lbs
- Measurable edge thickness: 0.4 mm ... 3.5 mm
- Measurable thicknesses: 10 mm ... 64 mm
- Velocity: 0.3 m / min
Mechanical shore hardness tester for measuring hardness of soft elastomer with drag needle. The shore hardness tester is composed of a single component with a measuring head and a 360º dial. To improve the readability of peak value, the device comes with a drag needle, that ensures the maximum reading can be captured. Once it has been measured, it can be reset to zero.
- Force of pressure: 0 to 12.5 N
- Penetrating body: 35º (according to Shore A)
- Equipped with drag needle
- Measurement range: 10 ... 90
(pressure diminishes below 10 and above 90)
- Margin of error: ± 1
- Division of scale: 1
- incl. ISO Calibration Certificate