2 year Warranty
The pressure meter PCE-PDA 10L is a reliable differential pressure gauge for pressure measurement of gases in the range of ±20 kPa. The pressure meter PCE-PDA 10L has many different pressure measuring functions.
- Measuring range: ± 20 kPa / ± 2.9 psi / ± 0.2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
- Pitot tube not included in delivery / optionally selectable
The differential pressure meter PCE-PDA 01L is a reliable differential pressure gauge for pressure measurement of gases in the range of ± 200 Pa. The differential pressure meter PCE-PDA 01L has many different pressure measuring functions.
- Measuring range: ± 200 Pa / 0.029 psi / 0.002 bar
- Resolution: 0.1 Pa / 0.0000145 psi / 0.000001 bar
- Accuracy: ± 1% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
The relative pressure HVAC meter PCE-PDA 1000L measures the relative pressure on machines and systems. The relative pressure is measured by this HVAC pressure meter in the range between -100 ... 2000 kPa. The relative pressure HVAC meter PCE-PDA 1000L has a quick coupling connection with which the air pressure or water pressure can be directly applied to the device.
- Measuring range pressure: -100 ... 2000 kPa relative / -14.5 ... 290 PSI
- Resolution: 0.01 kPa, 0.1 kPa
- Accuracy: <± 0.5% of the measuring range
- USB interface
- Data logger
- Adjustable measuring units: Pa, hPa, kPa, MPa, mbar, bar, ATM, kg / cm², mmH2O, cmH2O, inH2O, mmHg, inHg, Torr, PSI, PSF
The Flow Meter PCE-PDA 10L is a reliable differential pressure gauge for pressure measurement of gases in the range of ±20 kPa. The Flow Meter PCE-PDA 10L has many different pressure measuring functions.
- Measuring range: ± 20 kPa / ± 2.9 psi / ± 0.2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
- Pitot tube not included in delivery / optionally selectable
The pressure gauge PCE-PDA A100L is suitable for the measurement of atmospheric pressure. This pressure gauge records the pressure from absolute zero to 200 kPa. The pressure gauge can be used for many mobile applications in industry and crafts.
- Measuring range pressure: 0 ... 200 kPa absolute
- Resolution: 0.01 kPa, 0.1 kPa
- Accuracy: < ± 0.5% of the measuring range
- USB interface
- Datalogger
- Different units
The pressure meter PCE-PDA A100L is suitable for the measurement of atmospheric pressure. This pressure meter records the pressure from absolute zero to 200 kPa. The pressure gauge can be used for many mobile applications in industry and crafts.
- Measuring range pressure: 0 ... 200 kPa absolute
- Resolution: 0.01 kPa, 0.1 kPa
- Accuracy: < ± 0.5% of the measuring range
- USB interface
- Datalogger
- Different units
The pressure gauge PCE-PDA 100L is a reliable differential pressure gauge for pressure measurement of gases in the range of -100 to +200 kPa. The pressure gauge PCE-PDA 100L has many different pressure measuring functions.
- Measuring range: -100 ... 200 kPa / -14.5 ... 29 psi / -1 ... 2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
The pressure meter PCE-PDA 100L is a reliable differential pressure gauge for pressure measurement of gases in the range of -100 to +200 kPa. The pressure meter PCE-PDA 100L has many different pressure measuring functions.
- Measuring range: -100 ... 200 kPa / -14.5 ... 29 psi / -1 ... 2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
The HVAC meter PCE-PDA A100L is suitable for the measurement of atmospheric pressure. This HVAC meter records the pressure from absolute zero to 200 kPa. The HVAC meter can be used for many mobile applications in industry and crafts.
- Measuring range pressure: 0 ... 200 kPa absolute
- Resolution: 0.01 kPa, 0.1 kPa
- Accuracy: < ± 0.5% of the measuring range
- USB interface
- Datalogger
- Different units
The HVAC meter PCE-PDA 10L is a reliable differential pressure gauge for pressure measurement of gases in the range of ±20 kPa. The HVAC meter PCE-PDA 10L has many different pressure measuring functions.
- Measuring range: ± 20 kPa / ± 2.9 psi / ± 0.2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
- Pitot tube not included in delivery / optionally selectable
The HVAC meter PCE-PDA 100L is a reliable differential pressure gauge for pressure measurement of gases in the range of -100 to +200 kPa. The HVAC meter PCE-PDA 100L has many different pressure measuring functions.
- Measuring range: -100 ... 200 kPa / -14.5 ... 29 psi / -1 ... 2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
The air flow meter PCE-PDA 10L is a reliable differential pressure gauge for pressure measurement of gases in the range of ±20 kPa. The air flow meter PCE-PDA 10L has many different pressure measuring functions.
- Measuring range: ± 20 kPa / ± 2.9 psi / ± 0.2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
- Pitot tube not included in delivery / optionally selectable
The wind speed meter PCE-PDA 10L is a reliable differential pressure gauge for pressure measurement of gases in the range of ±20 kPa. The wind speed meter PCE-PDA 10L has many different pressure measuring functions.
- Measuring range: ± 20 kPa / ± 2.9 psi / ± 0.2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
- Pitot tube not included in delivery / optionally selectable
The Air Velocity Meter PCE-PDA 10L is a reliable differential pressure gauge for pressure measurement of gases in the range of ±20 kPa. The Air Velocity Meter PCE-PDA 10L has many different pressure measuring functions.
- Measuring range: ± 20 kPa / ± 2.9 psi / ± 0.2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
- Pitot tube not included in delivery / optionally selectable
The differential pressure meter PCE-PDA 10L is a reliable differential pressure gauge for pressure measurement of gases in the range of ±20 kPa. The differential pressure meter PCE-PDA 10L has many different pressure measuring functions.
- Measuring range: ± 20 kPa / ± 2.9 psi / ± 0.2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
- Pitot tube not included in delivery / optionally selectable
The differential pressure meter PCE-PDA 100L is a reliable differential pressure gauge for pressure measurement of gases in the range of -100 to +200 kPa. The differential pressure meter PCE-PDA 100L has many different pressure measuring functions.
- Measuring range: -100 ... 200 kPa / -14.5 ... 29 psi / -1 ... 2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
The pitot pipe anemometer is a reliable differential pressure gauge for pressure measurement of air in the range of ±20 kPa. The Anemometer can be used in combination with various pitot pipes what makes the instrument very useful in air flow measurements of industrial plants.
- Measuring range: ± 20 kPa / ± 2.9 psi / ± 0.2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
- Pitot tube not included in delivery / optionally selectable