2 year Warranty
This data logger with USB interface is a 12-channel temperature data logger that accommodates SD cards up to 16 GB in size. The optional software allows the data logger to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
- Includes 2 Type K sensors 1-meter in length
The data logger with USB interface is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy data logger with USB interface has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
The power data logger (Graphic Power Quality Analyzer) PCE-GPA 62 is used for single-phase or three-phase measurements of the active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics.
- Real-time test, register and measurement of voltage and current (real and effective)
- Measures power factor and phase angle, frequency, energy, active, reactive and apparent power
(single-phase or three-phase in symmetrical networks).
- Max. conductor diameter: 55 mm / 2.2 in
- Records up to 50,000 records
PCE-T 1200 is a 12-channel temperature data logger that accommodates SD cards up to 16 GB in size. The optional software allows the temperature data logger to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
- Includes 2 Type K sensors 1-meter in length
The data logger PCE-PDA 1000L measures the relative pressure on machines and systems. The relative pressure is measured by this data logger in the range between -100 ... 2000 kPa. The data logger PCE-PDA 1000L has a quick coupling connection with which the air pressure or water pressure can be directly applied to the device.
- Measuring range pressure: -100 ... 2000 kPa relative / -14.5 ... 290 PSI
- Resolution: 0.01 kPa, 0.1 kPa
- Accuracy: <± 0.5% of the measuring range
- USB interface
- Data logger
- Adjustable measuring units: Pa, hPa, kPa, MPa, mbar, bar, ATM, kg / cm², mmH2O, cmH2O, inH2O, mmHg, inHg, Torr, PSI, PSF
The PCE-HT110 Humidity / Temperature Data Logger or Humidity Detector precisely measures air temperature and relative humidity. This accurate and reliable device shows the current measurements on the large LCD display and saves the measurement data directly to an SD card (included). The PCE-HT110 is equipped with two channels, accommodates an SD card memory of up to 16 GB, offers an adjustable measurement rate / sampling interval, and includes a wall mount, making the device ideal for logging data over an extended period of time.
- Measurement ranges: 0 … 50°C / 32 ... 122°F, 10 ... 90% RH
- Resolution: 0.1°C / 0.18°F, 0.1% RH
- Data format: .XLS (compatible with Microsoft Excel)
- Set = Quantity of 5 x units
The dB data logger is used to determine volume. The PCE-NDL 10 dB data logger is a handy measuring device that meets the highest requirements. In order to evaluate the measured data in the best possible way, it is possible to use the internal measurement data memory on the noise dosimeter. In addition, the dB data logger has an SD card slot that enables the use of an SD card as an additional storage medium.
- Measuring range: SPL: Auto 30 ... 130 dB
- Resolution: 0.1 dB
- Low sampling rate
- Automatic or manual storage
- Selectable storage interval
- Backlit LC display
- Dose measurement or SPL measurement