2 year Warranty
Moisture meter for liquid materials are used in boiler installations, water-dosing and diesel oil emulsion dispersion systems. The scope of supply can include the control cabinet to operate the valves regulating water feed. The moisture meter for liquid materials has a processing unit with RS232/RS485 interfaces.
- Measurement range: 0 ... 100 %
- Limits of permissible absolute error of the measurements: Δ= 0,035 +0,05·W
- Temperature measurement range: -40 ... +150 °C
The moisture meter PCE-MA 100-ICA allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the moisture meter dries the material to be weighed, and then calculates the moisture content from the weight difference.
- Testing or weighing capacity: 110 g / 3.88 oz
- Readability: 1 mg / 0.001 g / 0.01 %
- Adjustable drying temperature and time
- incl. ISO Calibration Certificate
PCE-WP24 is a wood moisture analyzer or meter used to perform noninvasive, nondestructive moisture measurements of wood, timber and other construction or building materials. An ideal tool for assessing everything from lumber to floors and more, this moisture meter uses electromagnetic waves that penetrate approximately 50 mm / 1.96 inches to 60 mm / 2.36 inches deep (depending on substrate) to return a mean-value moisture content percentage.
- Moisture content measuring range: 4% ... 60% wood, 0% ... 10% building
materials
- Resolution: 0.1%
- Accuracy: ±0.7%
The hay thermometer PCE-HMM is a professional device to designed to determine moisture and temperature of pressed hay and straw. The hay thermometer features a sensor made of stainless steel, which can be purchased in four different lengths, while the wooden handle has an ergonomic design. The hay thermometer proves to be extremely robust, designed to withstand applications for many years.
- Measuring lance: 50 cm
- Measuring range moisture: 9 ... 50%
- Measuring range temperature: -10 ... 100°C / 14 ... 212°F
- Resolution of display: 0.1%
- Accuracy: 0.8%
PCE-MA 110 is a halogen moisture balance that functions on the gravimetric or loss on drying (LOD) principle. The moisture balance uses the halogen method to dry the material sample. The moisture balance determines moisture content based on the weight difference before and after the drying procedure. Calibration of the moisture balance can be performed at any time using the automatic calibration function and the included 100 g weight.
- Weighing range: 0.01 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.1 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 15 drying profiles
The PCE-MA 202 is an oven-drying moisture analyzing balance for weighing and heating material samples to determine moisture content. The heating chamber warms up to 199 °C / 390 °F with the use of halogen lamps. Drying of the sample to be weighed takes place within the chamber of the moisture analyzing balance and the moisture content is subsequently calculated from the difference between the initial and final weight.
- Testing or weighing sample capacity: 200 g / 7.05 oz
- Moisture content measurement range: 0 ... 100 %
- Readout, readability or resolution: 10 mg / 0.01 g / 0.1 %
- Adjustable drying temperature and time
- Memory for up to 15 drying programs
Moisture sensor for liquid materials are used in boiler installations, water-dosing and diesel oil emulsion dispersion systems. The scope of supply can include the control cabinet to operate the valves regulating water feed. The moisture sensor for liquid materials has a processing unit with RS232/RS485 interfaces.
- Measurement range: 0 ... 100 %
- Limits of permissible absolute error of the measurements: Δ = 0,035 +0,05·W
- Temperature measurement range: -40 ... +150 °C
The hay contact thermometer PCE-HMM is a professional device to designed to determine moisture and temperature of pressed hay and straw. The hay contact thermometer features a sensor made of stainless steel, which can be purchased in four different lengths, while the wooden handle has an ergonomic design. The hay contact thermometer proves to be extremely robust, designed to withstand applications for many years.
- Measuring lance: 50 cm
- Measuring range moisture: 9 ... 50%
- Measuring range temperature: -10 ... 100°C / 14 ... 212°F
- Resolution of display: 0.1%
- Accuracy: 0.8%
The hay digital thermometer PCE-HMM is a professional device to designed to determine moisture and temperature of pressed hay and straw. The hay digital thermometer features a sensor made of stainless steel, which can be purchased in four different lengths, while the wooden handle has an ergonomic design. The hay digital thermometer proves to be extremely robust, designed to withstand applications for many years.
- Measuring lance: 50 cm
- Measuring range moisture: 9 ... 50%
- Measuring range temperature: -10 ... 100°C / 14 ... 212°F
- Resolution of display: 0.1%
- Accuracy: 0.8%
The PCE-MA 202-ICA is an oven-drying multifunction moisture analyzer for weighing and heating material samples to determine moisture content. The heating chamber warms up to 199 °C / 390 °F with the use of halogen lamps. Drying of the sample to be weighed takes place within the chamber of the multifunction moisture analyzer and the moisture content is subsequently calculated from the difference between the initial and final weight.
- Weighing range: 200 g / 7.05 oz
- Moisture measurement range: 0 ... 100 %
- Resolution: 10 mg / 0.01 g / 0.1 %
- Adjustable drying temperature and time
- Memory for up to 15 drying programs
- incl. ISO Calibration Certificate
The hay probe thermometer PCE-HMM is a professional device to designed to determine moisture and temperature of pressed hay and straw. The hay probe thermometer features a sensor made of stainless steel, which can be purchased in four different lengths, while the wooden handle has an ergonomic design. The hay probe thermometer proves to be extremely robust, designed to withstand applications for many years.
- Measuring lance: 50 cm
- Measuring range moisture: 9 ... 50%
- Measuring range temperature: -10 ... 100°C / 14 ... 212°F
- Resolution of display: 0.1%
- Accuracy: 0.8%
PCE-MA 110 is a halogen moisture analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the moisture analyzer can be performed at any time using the automatic calibration function and the included 100 g weight.
- Weighing range: 0.1 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.01 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
- Incl. ISO calibration certificate
The Temperature Meter PCE-HMM is a professional device to designed to determine moisture and temperature of pressed hay and straw. The Temperature Meter features a sensor made of stainless steel, which can be purchased in four different lengths, while the wooden handle has an ergonomic design. The Temperature Meter proves to be extremely robust, designed to withstand applications for many years.
- Measuring lance: 50 cm
- Measuring range moisture: 9 ... 50%
- Measuring range temperature: -10 ... 100°C / 14 ... 212°F
- Resolution of display: 0.1%
- Accuracy: 0.8%
The hay thermo hygrometer PCE-HMM is a professional device to designed to determine moisture and temperature of pressed hay and straw. The hay thermo hygrometer features a sensor made of stainless steel, which can be purchased in four different lengths, while the wooden handle has an ergonomic design. The hay thermo hygrometer proves to be extremely robust, designed to withstand applications for many years.
- Measuring lance: 50 cm
- Measuring range moisture: 9 ... 50%
- Measuring range temperature: -10 ... 100°C / 14 ... 212°F
- Resolution of display: 0.1%
- Accuracy: 0.8%
For industrial continuous production of wood pellets, chips, sawdust and similar materials when in-line moisture measurement for monitoring and controlling the drying and mixing process is important. Consistent quality of every batch, reduction of the consumption of materials, and shortest possible drying and mixing times are the criteria which are important in materials production.
- Measuring range: 0 ... 100%
- The maximum permissible error (absolute): Lab analysis of your sample determines % error
- Temperature range: +5 ... +80 °C (+41 ... +176 °F)
- Questionnaire starts evaluation process