2 year Warranty
The Electrical Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Electrical Tester also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The HVACR Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase HVACR Tester also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The HVACR Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This HVACR Tester also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The environmental tester is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy environmental tester has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
The material hardness tester PCE-2900 has been developed for hardness measurements on metallic materials.
The material hardness tester PCE-2900 measures the material hardness in Vickers, Brinell, Rockwell, Leeb and Shore.
The material hardness tester PCE-2900 measures the hardness according to the Leeb rebound principle.
- Measurement according to Leeb Rebound method
- Measurement units: HLD, HRA, HRB, HRC, HB, HV, HS
- Measurement ranges: 170-960 HLD, 59.1-88 HRA, 3.5-101.7 HRB, 17.9-69.5 HRC, 19-683 HB, 80-1042 HV, 30.6-102.6 HS
- Accuracy: ± 0.5%, Repeatability: ± 0.6%
- Impactor: Type D
- USB and WiFi for data transmission
- Incl. ISO Calibration Certificate
The hardness tester PCE-2900 has been developed for hardness measurements on metallic materials.
The hardness tester PCE-2900 measures the material hardness in Vickers, Brinell, Rockwell, Leeb and Shore.
The hardness tester PCE-2900 measures the hardness according to the Leeb rebound principle.
- Measurement according to Leeb Rebound method
- Measurement units: HLD, HRA, HRB, HRC, HB, HV, HS
- Measurement ranges: 170-960 HLD, 59.1-88 HRA, 3.5-101.7 HRB, 17.9-69.5 HRC, 19-683 HB, 80-1042 HV, 30.6-102.6 HS
- Accuracy: ± 0.5%, Repeatability: ± 0.6%
- Impactor: Type D
- USB and WiFi for data transmission
- Incl. ISO Calibration Certificate
The hardness tester PCE-2900 has been developed for hardness measurements on metallic materials.
The hardness tester PCE-2900 measures the material hardness in Vickers, Brinell, Rockwell, Leeb and Shore.
The hardness tester PCE-2900 measures the hardness according to the Leeb rebound principle.
- Measurement according to Leeb Rebound method
- Measurement units: HLD, HRA, HRB, HRC, HB, HV, HS
- Measurement ranges: 170-960 HLD, 59.1-88 HRA, 3.5-101.7 HRB, 17.9-69.5 HRC, 19-683 HB, 80-1042 HV, 30.6-102.6 HS
- Accuracy: ± 0.5%, Repeatability: ± 0.6%
- Impactor: Type D
- USB and WiFi for data transmission
- Incl. ISO Calibration Certificate
The Material Surface Roughness Tester PCE-RT 10-ICA is a small, light device with simple navigation. Despite the fact that the device functions on a very complex and elaborate level, the measurement results can be acquired quickly and in an accurate way. Very simple to operate with a motorized diamond sensor.
- Measures Ra in Metric (µm) and Imperial (µinch)
- Ra 0.05 to 10um / 2 µinch ... 400 µinch measurement range
- Rz 0.1 to 50um / 3.93 µinch ... 1968.50 µinch measurement range
- Induction method with Diamond sensor
- Accuracy < ± 10% and Repeatability < 6%
- With threshold function
- Uses 4 AA Batteries (Included)