2 year Warranty
The 4-channel PCE-VM 5000-ICA Condition Monitoring Vibration Meter performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration measuring device is able to record vibrations at different points of the component to be tested.
- 4 channels / inputs
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity, displacement
- Connection of up to 4 sensors simultaneously, 2 included
- Data storage on SD card
- Sampling rate: minimum 1 sec.
- Incl. ISO calibration certificate
- Measures Ra, Rz, Rq and Rt in Metric (µm) and Imperial (µinch)
- Ra, Rq: 0.005 ... 16.00 μm / 0.197µinch... 629.921 µinch measurement range
- Rz, Rt: 0.002 ... 200.0 μm / 0.079µinch... 7874.016 µinch measurement range
- Induction method with Diamond sensor
- Accuracy < ± 10% and Repeatability < 6%
- Saves up to 20 Data points
- Micro-USB interface
- Built-in rechargeable li-ion battery
- Incl. ISO calibration certificate
The magnetometer is used in the laboratory and quality assurance to measure the strength of magnetic fields. The magnetometer is delivered with two different sensors. A magnetic field sensor is available for general measurements in the Gauss and milli-Tesla range, as well as a precision sensor for measurements in the milli-Gauss and micro-Tesla range.
- Tabletop device with 2 sensors
General Probe Range: 0-3000 milli-Tesla (0-30,000 Gauss)
Precision Probe Range: 0-300 micro-Tesla (0-3000 milli-Gauss)
- For static and changing magnetic fields
- Highly accurate Transverse Hall sensor
- Different units selectable (mG / µT)
- Data storage on SD memory card
- Incl. ISO calibration certificateThe Electromagnetic Field Meter is used in the laboratory and quality assurance to measure the strength of magnetic fields. The Electromagnetic Field Meter is delivered with two different sensors. A magnetic field sensor is available for general measurements in the Gauss and milli-Tesla range, as well as a precision sensor for measurements in the milli-Gauss and micro-Tesla range.
- Tabletop device with 2 sensors
General Probe Range: 0-3000 milli-Tesla (0-30,000 Gauss)
Precision Probe Range: 0-300 micro-Tesla (0-3000 milli-Gauss)
- For static and changing magnetic fields
- Highly accurate Transverse Hall sensor
- Different units selectable (mG / µT)
- Data storage on SD memory card
The Surface Tester PCE-RT 11-ICA is a portable measuring instrument for determination of surface roughness according to Ra, Rz, Rq and Rt in just one device. The small roughness tester is especially designed for fast measuring of roughness. The roughness is a term of surface physics that describes unevenness of surface height.
- Measures Ra, Rz, Rq and Rt in both Metric (µm) and Imperial (µinch)
- Ra, Rq: 0.05 µm … 10 µm / 0.002 µinch … 394 µinch measurement range
- Rz, Rt: 0.1 µm … 50 µm / 0.004 µinch …1968 µinch measurement range
- Robust Piezoelectric sensor
- Accuracy: ± 15% and Repeatability < 12%
- Built-in rechargeable li-ion battery
- Inc. ISO Calibration Certificate
- Measures Ra, Rz, Rq and Rt in Metric (µm) and Imperial (µinch)
- Ra, Rq: 0.005 ... 16.00 μm / 0.197µinch... 629.921 µinch measurement range
- Rz, Rt: 0.002 ... 200.0 μm / 0.079µinch... 7874.016 µinch measurement range
- Induction method with Diamond sensor
- Accuracy < ± 10% and Repeatability < 6%
- Saves up to 20 Data points
- Micro-USB interface
- Built-in rechargeable li-ion battery
- Incl. ISO calibration certificate