2 year Warranty
The PCE-830 3-Phase Power Meter / 3-Phase Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Power Meter / 3-Phase Power Analyzer also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.2 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate
The PCE-830 3-Phase Power Meter / 3-Phase Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Power Meter / 3-Phase Power Analyzer also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The 3-Phase-Power Meter / 3-Phase Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase-Power Meter / 3-Phase Power Analyzer also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.1 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
The Three-Phase Power Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Three-Phase Power Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000 A)
- Electrical conductor pick-up: 170 mm / 6.69 in diameter
- Length of electrical conductor: 610 mm / 24.0 in
- Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values - single phase)
The PCE-830-3 3-Phase Power Meter / 3-Phase Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Power Meter / 3-Phase Power Analyzer also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The Electrical Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Electrical Tester also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The easy-to-use 3-Phase Power Meter / 3-Phase Power Analyzer is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. This is a 3-phase power analyzer that features:
- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 2) 30 A ... 3000 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage
The easy-to-use 3-Phase Power Meter / 3-Phase Power Analyzer is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. This is a 3-phase power analyzer that features:
- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 1) 20 A ... 1200 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage
PCE-FD 20 is a portable ultrasonic tester or ultrasonic thickness gauge with a large LCD screen that displays A-scan maps of ultrasonic signals as well as B-scan cross sections. Ideal for use in mechanical engineering, aerospace and metallurgical applications, this high-frequency ultrasound-based thickness meter uses a contact transducer (two different probes included; 45° and 90°) to measure material thickness and identify flaws and defects such as discontinuity in welds.
- Operating frequency range: 1 ... 10 MHz
- Measured time interval range: 6 ... 1000 microseconds (µs)
- Sound velocity: 1000 ... 9999 m/s