2 year Warranty
The data logger with USB interface is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy data logger with USB interface has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
PCE-PCO 1 is a handheld data logger for measuring the concentration of particles in the air. The PCE-PCO 1 data logger:
- Measures 6 sizes of particles: 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10 µm
- Offers a robust, 80 MB internal memory
- Features a large, full-color LCD display with backlight
- Includes a built-in camera for image and video recording
- Contains sensors for measuring air temperature, dew point and relative
humidity
- Displays temperature in degrees Celsius (°C) or Fahrenheit (°F)
The PCE-830 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The PCE-830 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm diameter / 2.2 in
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate
This 12-channel temperature data logger accommodates SD cards up to 16 GB in size. The optional software allows the temperature meter to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
- Includes 2 Type K sensors 1-meter in length
PCE-T 1200 is a 12-channel temperature data logger that accommodates SD cards up to 16 GB in size. The optional software allows the temperature data logger to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
This 12-channel temperature data logger accommodates SD cards up to 16 GB in size. The optional software allows the temperature meter to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
The data logger PCE-PDA 1000L measures the relative pressure on machines and systems. The relative pressure is measured by this data logger in the range between -100 ... 2000 kPa. The data logger PCE-PDA 1000L has a quick coupling connection with which the air pressure or water pressure can be directly applied to the device.
- Measuring range pressure: -100 ... 2000 kPa relative / -14.5 ... 290 PSI
- Resolution: 0.01 kPa, 0.1 kPa
- Accuracy: <± 0.5% of the measuring range
- USB interface
- Data logger
- Adjustable measuring units: Pa, hPa, kPa, MPa, mbar, bar, ATM, kg / cm², mmH2O, cmH2O, inH2O, mmHg, inHg, Torr, PSI, PSF
This data logger with USB interface is a 12-channel temperature data logger that accommodates SD cards up to 16 GB in size. The optional software allows the data logger to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
- Includes 2 Type K sensors 1-meter in length
This power datalogger is used for single-phase or three-phase measurements of the active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics up to 50º of the harmonic waveform. The power analyzer clamp is equipped with data logger. The test instrument is delivered manufacturer ISO calibrated.
- Real-time test, register and measurement of voltage and current (real and effective)
- Measures power factor and phase angle, frequency, energy, active, reactive and apparent power
(single-phase or three-phase in symmetrical networks).
- Max. conductor diameter: 55 mm / 2.2 in
- Datalogger for 50,000 readings / software/ USB interface
- incl. ISO Calibration Certificate