Condition Monitoring Device PCE-TG 300-NO5/90
£ 889.00
Price excl. VAT &. delivery
2 year Warranty
Wireless

The PCE-TG 300-NO5/90 is a condition monitoring device for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the condition monitoring device. Wall thicknesses under a coating can also be measured with the condition monitoring device.

- Measuring range: 1 ... 600 mm / 0.039 ... 23.62" (steel)
- Diameter: 10mm / 0.39"
- Sensor at 90° angle
- Minimum diameter of pipes: 20 x 3 mm / 0.787 ... 0.118"
- Frequency: 5 MHz
- Bluetooth

Dust Monitor PCE-CPC 100
£ 4,138.00
Price excl. VAT &. delivery
2 year Warranty
Topseller
The state-of-the-art dust monitor enables precise real-time measurement in the range of 0.3 μm to 10 μm to provide a comprehensive picture of air quality. The results are presented in two units, either number per 28.3 litres or number per cubic metre. Air sampling from the dust monitor is done by an internal pump.

Real-time measurement from 0.3 μm ... 10 μm
Output in particles/28.3L or particles/m³
- Visual and audible alarm
  when threshold value is exceeded
- Modbus RTU and MQTT via RS485
- Temperature and humidity measurement
Real-time display of clean room class
  ISO 14644-1
Condition Monitoring Device PCE-TG 300-HT5-ICA incl. ISO calibration certificate
£ 1,166.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration
The PCE-TG 300-HT5 is a condition monitoring device for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the condition monitoring device. Wall thicknesses under a coating can also be measured with the condition monitoring device.

- Measuring range: 1 ... 600 mm / 0.039 ... 23.62" (steel)
- Diameter: 12mm / 0.47"
- Minimum diameter of pipes: 30 mm / 1.18"
- Frequency: 5MHz
- Bluetooth
- incl. ISO calibration certificate
Condition Monitoring - Industrial Borescope PCE-VE 330N
£ 757.00
Price excl. VAT &. delivery
2 year Warranty

The PCE-VE 330N is an industrial borescope, inspection camera or industrial endoscope for the non-destructive inspection (NDI) of engines, machines and more. This industrial borescope is an ideal tool for diagnosing issues in hard-to-reach places. The waterproof camera head features 4 LED lights with automatic illumination. In addition, digital image magnification or zoom of up to 2 times is available.

 

- Diameter camera head: Ø 5.5mm / 0.22"
- Interface: Mini-USB 1.1 and AV out
- Memory: 8 GB SD memory card (incl.)
- Cable length: 2 m / 6ft 6"

Condition Monitoring Ultrasonic Material Thickness Meter PCE-TG 150 HT
£ 846.00
Price excl. VAT &. delivery
2 year Warranty
The condition monitoring ultrasonic material thickness meter can measure material thicknesses up to 300 mm. So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding sound velocity in the condition monitoring ultrasonic material thickness meter.

- Measuring range: 1.20 ... 300.0 mm  / 0.04 ... 11.81"
- Accuracy: ±0.5% of measured value + 0.05 mm
- Memory capacity: 1500 measured values
- Calibration reference on housing
- High temperature probe: -10 ... 350 °C / 14 ...  662 °F
Condition Monitoring Rotation Meter PCE-LES 103UV-365
£ 623.00
Price excl. VAT &. delivery
2 year Warranty
Motion analysis of rotating machines is quick and easy with our rotation meter. The rotation meter is equipped with 3 UVA high-power LEDs, which together generate a light intensity of 202 μW/cm² at a distance of 30 cm.

- Flash frequency 60 ... 300000 FPM
- Accuracy: 0.001 %
- Light colour: UV light (365 ... 370 nm)
- Digital pulse width modulation
- Phase shift - 360 ° ... + 360 °
- Quick adjustment using x2 and ÷2 button
- 3 UVA high-power LEDs
Condition Monitoring Vibration Meter PCE-VT 3700
£ 685.00
Price excl. VAT &. delivery
2 year Warranty
The condition monitoring vibration meter is ideal for maintenance workers to quickly check vibrating parts, machines and systems. This condition monitoring vibration meter shows the vibration acceleration, vibration velocity and vibration displacement directly on the display. The measurement unit can be switched between the metric system and imperial units.

Measuring ranges
- Acceleration: 0.0 - 399.9 m/s² / 0.0 - 15744 in/s²
- Velocity: 0.00 - 399.99 mm/s / 0.00 - 15.74 in/s
- Displacement: 0.000 - 3.9 mm / 0.000 - 0.154 in
- Automatic ISO 10816-3 evaluation
- Colored graphic display
Condition Monitoring - Industrial Borescope PCE-VE 320N
£ 735.00
Price excl. VAT &. delivery
2 year Warranty

The PCE-VE 320N is an industrial borescope, inspection camera or industrial endoscope for the non-destructive inspection (NDI) of engines, machines and more. This industrial borescope is an ideal tool for diagnosing issues in hard-to-reach places. The waterproof camera head features 4 LED lights with automatic illumination. In addition, digital image magnification or zoom of up to 2 times is available.

 

- Diameter camera head: Ø 5.5 mm / 0.22"
- Cable length: 1 m / 3ft 3"
- Interface: mini-USB 1.1 and AV out
- Memory: 8 GB SD memory card (incl.)

Condition Monitoring Sound Level Meter PCE-428-Kit-N with Sound Calibrator
£ 1,090.00
Price excl. VAT &. delivery
2 year Warranty
The condition monitoring sound level meter is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The condition monitoring sound level meter is a class 2 device and is equipped with an octave band frequency filter. The sound level meter can optionally be upgraded with a 1/3 octave band filter.

- Accuracy class 2
- A, B, C & Z frequency weighting
- Fast, Slow, Impulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Including class II sound calibrator
Condition Monitoring Sound Level Meter PCE-428-ICA incl. ISO Calibration Cert.
£ 1,081.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration

The condition monitoring sound level meter is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy condition monitoring sound level meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).

- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate

Condition Monitoring Sound Level Meter (Badge Type) PCE-MND 10
£ 885.00
Price excl. VAT &. delivery
2 year Warranty
The condition monitoring sound level meter (badge type) was specially developed for measuring noise exposure in workplaces and complies with the IEC 61252:2002 standard. With a measuring range of 70 … 140 dB and a frequency weighting of A, B and Z, the condition monitoring sound level meter is ideal for this.

- Measuring range: 70 ... 140 dB
- Frequency weighting: A, B and Z
- Battery life: >15 hours
- LEQ measurement
- Memory
- USB interface
- Battery / power supply
- Software download
- Standards: IEC 61252:2002, ANSI S1.25-1991
Condition Monitoring Device PCE-TG 300-NO2-ICA incl. ISO calibration certificate
£ 1,050.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration
The PCE-TG 300-NO2 is a condition monitoring device for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the condition monitoring device. Wall thicknesses under a coating can also be measured with the condition monitoring device.

- Measuring range: 3.0 … 300.0 mm / 0.118 ... 11.81" (steel)
- Diameter: 14 mm / 0.55"
- Minimum diameter of pipes: 30 mm / 1.18"
- Frequency: 2.5 MHz
- Bluetooth
- incl. ISO calibration certificate
Condition Monitoring Device PCE-TG 300-NO7-ICA incl. ISO calibration certificate
£ 1,046.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration
The PCE-TG 300-NO7 is a condition monitoring device for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the condition monitoring device. Wall thicknesses under a coating can also be measured with the condition monitoring device.

- Measuring range: 0.65 ... 200 mm / 0.025 ...  7.87" (steel)
- Diameter: 6 mm / 0.23"
- Minimum diameter of pipes: 15 x 2 mm / 0.59 x 0.07"
- Frequency: 7 MHz
- Bluetooth
- incl. ISO calibration certificate
Condition Monitoring Rotation Meter PCE-LES 103UV-385
£ 574.00
Price excl. VAT &. delivery
2 year Warranty
Motion analysis of rotating machines is quick and easy with our rotation meter. The rotation meter is equipped with 3 high-power UVA LEDs (385 nm), which together generate a light intensity of 317 μW/cm² at a distance of 30 cm.

Flash frequency 60 ... 300000 FPM
- Light colour: UV light (380 ... 390 nm)
Accuracy: 0.001 %
- Digital pulse width modulation
- Phase shift - 360 ° ... + 360 °
- Quick adjustment with x2 and ÷2 button
3 UVA high-power LEDs
Condition Monitoring Device PCE-TG 300-NO5-ICA incl. ISO calibration certificate
£ 1,015.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration
The PCE-TG 300-NO5 is a condition monitoring device for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the condition monitoring device. Wall thicknesses under a coating can also be measured with the condition monitoring device.

- Measuring range: 1 ... 600 mm / 0.039 ... 23.62" (steel)
- Diameter: 10mm / 0.39"
- Minimum diameter of pipes: 20 x 3 mm / 0.787 ... 0.118"
- Frequency: 5 MHz
- Bluetooth
- incl. ISO calibration certificate
Condition Monitoring Vibration Meter PCE-VT 3800S-ICA incl ISO Calibration Cert.
£ 1,006.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration
The condition monitoring vibration meter is the ideal companion for checking vibrating parts, machines and systems. With the external vibration sensor on the condition monitoring vibration meter, the vibration displacement up to 3.9 mm, the vibration velocity up to 399.9 mm/s and the vibration acceleration up to 399.9 m/s² can be determined.

Measuring ranges
- Acceleration: 0.0 ... 399.9 m/s² / 0.0 - 15744 in/s²
- Velocity: 0.00 ... 399.9 mm/s / 0.00 - 15.74 in/s
- Displacement: 0.000 ... 3.9 mm / 0.000 - 0.154 in
- Automatic ISO 10816-3 evaluation
- Data logger: 50 memory locations with 43200 measured values each
- Rechargeable battery
- Color graphic display
- Measuring tip with handgrip
- incl. ISO Calibration Certificate
Condition Monitoring Device PCE-TG 300-NO5/90-ICA incl. ISO calibration certificate
£ 997.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration

The PCE-TG 300-NO5/90 is a condition monitoring device for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the condition monitoring device. Wall thicknesses under a coating can also be measured with the condition monitoring device.

- Measuring range: 1 ... 600 mm / 0.039 ... 23.62" (steel)
- Diameter: 10mm / 0.39"
- Sensor at 90° angle
- Minimum diameter of pipes: 20 x 3 mm / 0.787 ... 0.118"
- Frequency: 5 MHz
- Bluetooth
- incl. ISO calibration certificate

Condition Monitoring Material Thickness Meter PCE-TG 150 HT-ICA incl.Certificate
£ 953.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration
The condition monitoring ultrasonic material thickness meter can measure material thicknesses up to 300 mm. So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding sound velocity in the condition monitoring ultrasonic material thickness meter.

- Measuring range: 1.20 ... 300.0 mm  / 0.04 ... 11.81"
- Accuracy: ±0.5% of measured value + 0.05 mm
- Memory capacity: 1500 measured values
- Calibration reference on housing
- High temperature probe: -10 ... 350 °C / 14 ...  662 °F
- incl. ISO Calibration Certificate