2 year Warranty
This sound level meter kit includes gauges for demanding applications with advanced functionality. The sound level meter kit has been specially formulated to meet all requirements with regard to the assessment of the environment. With these devices, the recorded values are saved and can then be evaluated on a PC or laptop. The sound level meter meter kit consists of the following devices:
- P1 / PCE-322A (Class 2)
- P2 / PCE-890U
- P3 / PCE-174
- P4 / PCE-330
The condition monitoring sound level meter is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy condition monitoring sound level meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
The environmental meter is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy environmental meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
The PCE-830 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The 4-channel PCE-VM 5000 vibration data logger performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration data logger is able to record vibrations at different points of the component to be tested.
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity and displacement
- Connection of up to 4 sensors simultaneously
- Data storage on SD card
- Including 2 additional sensors for vibration
The PCE-830-3 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The Sound Level Data Logger PCE-432 is a class 1 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level data logger is equipped with GPS functionality, allowing measured values to be assigned to a precise geographic location. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 22 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- GPS receiver for location determination
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
The 4-channel PCE-VM 5000 Vibration Meter performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration measuring device is able to record vibrations at different points of the component to be tested.
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity and displacement
- Connection of up to 4 sensors simultaneously
- Data storage on SD card
- Including 2 additional sensors for vibration
The data logger with USB interface is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy data logger with USB interface has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
PCE-TDS 100HSH-ICA is a portable handheld clamp-on ultrasonic HVAC meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 20 … 108 mm / approx. 3/4 in ... 4in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 15 … 700, 20 … 720 mm (approx. 3/4 … 28")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, (N,W)
- Incl. sensors TDS-M1 and TDS-S1
- Incl. ISO Calibration Certificate