2 year Warranty
The PCE-VE 200SV1 automotive tester is a nondestructive inspection camera. Thus, the PCE-VE 200SV1 automotive tester is the ideal instrument for diagnosing hard-to-reach areas. Thus, the areas of mechanical engineering, sanitary and heating construction, and the entire construction and construction industry are among the main applications of the automotive tester PCE-VE 200SV1.
- Camera head diameter 9 mm / 0.4 in
- Cable length: 1 m / 3.3 ft
- Interface: Micro USB 2.0
- Memory: Micro SD card
- Front and side view camera
PCE-OM 15-ICA is an automotive tester with trigger functionality. This easy-to-use portable digital stroboscope gun features high / low range selection and push-button rate control to scale the flash rate slower (x½) and faster (x2). In addition, two knobs allow coarse and fine adjustment of the flash rate.
- Measuring range: 50 ... 30000 rpm
- Bright 6500K xenon light bulb
- 10 mm / 0.4 in 5-digit LCD
- Incl. ISO Calibration Certificate
PCE-5000 is a portable material hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Non-destructive testing produces microscopic indentation.
- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available
PCE-5000 is a portable material hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Non-destructive testing produces microscopic indentation.
- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available