2 year Warranty
PCE-HVAC 3 is a HVAC meter or diagnostic measuring device used for indoor climate and environmental monitoring. In addition to measuring relative humidity and ambient room / dry-bulb temperature, the HVAC meter calculates dew-point and wet-bulb temperatures in degrees Celsius (°C) and Fahrenheit (°F). Thus, heating, ventilation and air conditioning (HVAC) installations and HVAC system performance assessments are key applications of the PCE-HVAC 3 HVAC meter.
- Relative humidity measuring range: 0 ... 100% RH
- Ambient / dew-point temp. range: -30 ... 100°C / -22 ... 212°F
- Wet-bulb temp. range: 0 ... 80°C / 32 ... 176°F
- Incl. ISO calibration certificate
The PCE-830 Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Analyzer also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.2 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate
The PCE-830 Power Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Meter also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.2 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate
The IR HVAC Meter was designed for taking non-contact temperature measurements. To get accurate readings, the emissivity of the thermometer can be adjusted, depending on the operation purpose. Besides taking infrared images, the thermometer can also take normal pictures, as well as a mixture of both, due to the built-in digital camera.
- Measurement range: -20 ... +600°C / -4 ... 1112°F
- Accuracy: ± 2%, ± 2°C / 3.6°F
- Frequency image recording: 9 Hz
- Camera: 32 x 31 Pixel
- incl. ISO Calibration Certificate
The PCE-830-2 HVAC Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This HVAC Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.1 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
The PCE-830 Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Power Analyzer also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The PCE-830 Power Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Power Meter also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The HVAC meter is suitable for relative measurements on various machines. With the 45 mm long needle probe, you can access hard-to-reach places in machines and motors. For this reason, this HVAC meter is used for rapid measurement of imbalance and for checking bearing and gear conditions.
- Frequency range: 10 Hz ... 1 kHz
- Measures speed, distance, acceleration in metric units
- Holds the reading after each measurement
- Portable and battery operated
- Needle probe: 45mm / 1.77"
- incl. ISO Calibration Certificate
The environmental meter with a pitot tube that measures air velocities up to 80 m/s. It is possible to measure air speed, air pressure, air flow, differential pressure and ambient temperature with this mobile environmental meter. Readings can be taken in narrow pipes and other restricted spaces because the pitot tube can be inserted in very small gaps.-
- Measures air velocities up to 80 m/s / 262 ft/s, 2.24 ... 178.66 MPH
- Zero, minimum, maximum, average, record and hold functions
- Stores to memory up to 99 measurement values per parameter
- Includes ISO calibration certificate
The PCE-HVAC 2 is a Flow Meter that measures air velocities up to 80 m/s. It is possible to measure air speed, air pressure, air flow, differential pressure and ambient temperature with this mobile Flow Meter. Readings can be taken in narrow pipes and other restricted spaces because the pitot tube can be inserted in very small gaps.-
- Measures air velocities up to 80 m/s / 262 ft/s, 2.24 ... 178.66 MPH
- Zero, minimum, maximum, average, record and hold functions
- Stores to memory up to 99 measurement values per parameter
- Includes ISO calibration certificate