2 year Warranty
PCE-430 is a class 1 data-logging noise dose meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy class 1 data-logging noise dose meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time.
- Measuring range: 22 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- Includes ISO calibration certificate
The HVAC meter is a portable handheld Clamp Meter used for the testing and inspection of 3-phase / 4-wire, 3-phase / 3-wire, 1-phase / 2-wire and 1-phase / 3-wire electrical circuits. This handy HVAC meter not only measures multiple electrical properties in real time, but also saves the measurement data in .xls format to the included SD card memory for quick and easy data transfer and analysis using Microsoft Excel.
- True RMS measurement for ACA, ACV
- True power: W, KW, MW
- VA, KVA, MVA, VAR, KVAR, MVAR
- PF (power factor), phase angle (Φ)
- KWH, KVAH, KVARH, PFH
- Voltage measurement range: 10 ... 600 ACV
- Current measurement range: 0.2 ... 1200 ACA
- Real-time current, voltage and power consumption measurement
- Built-in data recorder with adjustable sample rate: 2 ... 7,200 sec.
- Incl. ISO Calibration Certificate
The HVACR Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This HVACR Tester also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.2 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate
PCE-TDS 100H-ICA is a portable handheld clamp-on ultrasonic HVAC meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 57 … 720 mm / approx. 2 ... 28 in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 50 … 700, 57 … 720 mm (approx. 2 … 28")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-M1
- Incl. ISO Calibration Certificate
The HVACR Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This HVACR Tester also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
PCE-WM1-ICA is a multi-function air humidity meter used to determine relative humidity (% RH), absolute humidity (g/m³), air temperature, dew-point temperature and surface temperature (°C). This Metric-only measuring instrument comes complete with an external sensor probe for taking the surface temperature of different materials.
- Temperature range: -20 ... 80°C
- Relative humidity range: 10 ... 95% RH
- Absolute humidity range: 0.5 ... 74.4 g/m³
- incl. ISO Calibration Certificate
PCE-T 1200 is a 12-channel HVAC meter that accommodates SD cards up to 16 GB in size. The optional software allows the HVAC meter to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
The PCE-360 is a HVAC Meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.
- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB
(non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
- incl. ISO Calibration Certificate
- incl. ISO Calibration Certificate
The PCE-360 is a HVAC Meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.
- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB
(non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
- incl. ISO Calibration Certificate
- incl. ISO Calibration Certificate