2 year Warranty
The PCE-VA 20-SET is a multi-functional air velocity meter including flow hoods for assessing and balancing heating, ventilation and air conditioning or cooling (HVAC) installations. This multi-faceted anemometer-thermometer-hygrometer incorporates a 10 cm / 3.9" diam. fan impeller, easy-to-view backlit LCD, and useful functions, e.g. display hold, average val, maximum val, minimum val, auto power-off, low battery indication, and imperial/metric option.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew
point temperature and wet-bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±(3% of
measured value + 0.3 m/s) when more than 20 m/s
- Resolution: 0.1°C / 0.18°F
- Includes 2 x capture hoods (1 x round 210 mm / 8.3 in Ø, 1 x square 346 x 346
mm / 13.6 x 13.6 in)
- Incl. ISO Calibration Certificate
This Air Quality Meter Gas-Pro-2 can gauge with its sensors a maximum of five different gases. Because of this versatility, the Air Quality Meter Gas-Pro-2 is ideal for use in a variety of applications, such as near canals, sewage treatment plants, drains, wastewater facilities, dumps and landfills, chemical and oil plants, shipping ports and more.
- Purpose: Personal protection
- Sensor type: CO / H2S / O2 / CH4
- Memory: Yes
- Interface: USB
- Includes suction pump
- Other gas sensors available upon request. (Please email jmu@pce-instruments.com (UK) or jwe@pce-instruments.com (US) for details!)
The PCE-830-2 HVAC Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This HVAC Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.1 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
The PCE-VA 20-SET is a multi-functional air humidity meter including flow hoods for assessing and balancing heating, ventilation and air conditioning or cooling (HVAC) installations. This multi-faceted air humidity meter incorporates a 10 cm / 3.9" diam. fan impeller, easy-to-view backlit LCD, and useful functions, e.g. display hold, average val, maximum val, minimum val, auto power-off, low battery indication, and imperial/metric option.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew
point temperature and wet-bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±(3% of
measured value + 0.3 m/s) when more than 20 m/s
- Resolution: 0.1°C / 0.18°F
- Includes 2 x capture hoods (1 x round 210 mm / 8.3 in Ø, 1 x square 346 x 346
mm / 13.6 x 13.6 in)
- Incl. ISO Calibration Certificate
PCE-VA 20-SET is a multifunction air flow meter with capture hoods for assessing and balancing heating, ventilation and air conditioning or cooling (HVAC) systems. This combined hygrometer-anemometer-thermometer possesses a 10 cm / 3.9" diameter fan impeller and a bright backlit LCD. The functions of the air flow device incorporate display hold, mean value, max value, min value, battery-saving auto shutdown, low-battery display, and a choice between metric and imperial units.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew
point temperature and wet-bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±(3% of
measured value + 0.3 m/s) when more than 20 m/s
- Resolution: 0.1°C / 0.18°F
- Includes 2 x capture hoods (1 x round 210 mm / 8.3 in Ø, 1 x square 346 x 346
mm / 13.6 x 13.6 in)