2 year Warranty
PCE-VC21 is a vibration calibrator used to calibrate vibration sensors, meters, analyzers and testers. Suitable for calibrating equipment weighing up to 600 g (1.32 lb), this rechargeable-battery-powered vibration calibrator generates mechanical vibrations with adjustable quartz-stabilized vibration frequencies between 15.92 and 1280 Hz and adjustable vibration amplitudes between 1 m/s² and 20 m/s².
- Load-independent vibration magnitude
- 7 adjustable vibration frequencies
- 5 adjustable vibration amplitudes
PCE-VC21 is a vibration calibrator used to calibrate vibration sensors, meters, analyzers and testers. Suitable for calibrating equipment weighing up to 600 g (1.32 lb), this rechargeable-battery-powered vibration calibrator generates mechanical vibrations with adjustable quartz-stabilized vibration frequencies between 15.92 and 1280 Hz and adjustable vibration amplitudes between 1 m/s² and 20 m/s².
- Load-independent vibration magnitude
- 7 adjustable vibration frequencies
- 5 adjustable vibration amplitudes
PCE-AS1 is an air sampling meter used to assess microbiological pollution and monitor hygiene. Designed for use in hospitals, clean rooms, food, beverage, cosmetics, and pharmaceutical production facilities. The PCE-AS1 Particle Counter meets the latest requirements for devices used for airborne microbial analysis of bacterial and fungal counts. Rate is 100 lpm or 3.53 cfm with 300 micropores. **Optional ISO lab calibration listed under accessories**
- Accommodates manual adjustment of air volumes from 10 to 6000 liters
- Offers data storage for up to 99 parameters / 2000 measurement records
- Aids in compliance with HACCP, FDA FMSA, USP 797 and ISO 14698-1
- Runs off a rechargeable battery or AC power
- Supports standard Petri dishes of 90 mm / 3.5 in
- Software free as QR image for IOS / Android
The PCE-VM 40C Accelerometer with SMS alert functionality was designed for vibration and shock metering on buildings, bridges, towers, and other artificial structures. The Accelerometer measures vibrations in accordance to DIN 4150-3, BS 7385 and SN 640312A standards. With its internal memory for up to 100,000 readings, the PCE-VM 40C Accelerometer can determine the effects of construction sites, traffic, or industrial processing on buildings over a long period of time.
- Triaxial acceleration meter
- In accordance with BS 7385 standard
- Quad band GSM (optional)
- SMS alarm notifications (optional)
- Memory size of 100,000 values (SD card)
- Integrated NiMH battery
- FFT analysis, XYZ and vector sum display
The paint test equipment was developed for quality control, offers a high accuracy and comes with a 3.5" touch screen display. You can choose between different color spaces like CIE L*A*B, XYZ, Yxy, LCh, LUV, LCH, LAB &WI &YI, Color Fastness, and Staining Fastness. 400 to 700 nm photodiode array for 10 nm wavelength increments with Reflectance Curve graph.
- CIE L*A*B/LCh, CIE XYZ/Yxy, CIE LUV/LCH, LAB &WI &YI, Color Fastness, and Color Staining
- Measuring geometry 10° or 2°/d
- Black and white calibration
- Opacity, 18 light source options, metameric index, CIE 1976/1994/2000
- 1000 Standards, 15,000 sample memory
Suitable for determining the humidity of bulk substances, this moisture sensor can be fitted into containers and systems such as troughs, bunkers, distributors, augers, conveyors, bins and silos. This permits 24/7 moisture measurement of fibrous materials, sawdust, gravel, fly ash (mineral), wood chips (surface to 5 cm) feed grain, flour, pastes, seed, or similar bulk or flowing substances.
- PCE-MWM 240-B Rod sensor (custom length 500 ... 1500 mm)
- Lab analysis of your sample determines % error
- Measuring range: 0 ... 100%
- Material temperature range: -0 ... +80 °C (+41 ... +176 °F)
- Analog and digital signal output
Suitable for determining the humidity of bulk substances, this moisture test instrument can be fitted into containers and systems such as troughs,
bunkers, distributors, augers, conveyors, bins and silos. This permits
24/7 moisture measurement of fibrous materials, sawdust, gravel, fly ash
(mineral), wood chips (surface to 5 cm) feed grain, flour, pastes,
seed, or similar bulk or flowing substances. These test instruments / test sensors are mainly for use in manufacturing processes to give the opportunity of process optimization to the manufacturer or to insure the moisture content of the final product.
- PCE-MWM 240-B Rod sensor (custom length 500 ... 1500 mm)
- Lab analysis of your sample determines % error
- Measuring range: 0 ... 100%
- Material temperature range: -0 ... +80 °C (+41 ... +176 °F)
- Analog and digital signal output
PCE-COM 20 is a portable handheld non-destructive conductivity tester for non-ferrous metals. This non-destructive testing (NDT) device uses eddy current to determine the electrical conductivity of non-ferrous metals such as aluminum and copper. Includes 3 standards for testing.
- Operating frequency: 60 kHz
- Sine wave probe: Ø 14 mm / ≈ 0.55 in
- Memory: Up to 500 groups of measurements
- Lift-off and temperature compensation
- Automatic calibration
PCE-COM 20 is a portable handheld non-destructive conductivity tester for non-ferrous metals. This non-destructive testing (NDT) device uses eddy current to determine the electrical conductivity of non-ferrous metals such as aluminum and copper. Includes 3 standards for testing.
- Operating frequency: 60 kHz
- Sine wave probe: Ø 14 mm / ≈ 0.55 in
- Memory: Up to 500 groups of measurements
- Lift-off and temperature compensation
- Automatic calibration
Suitable for determining the humidity of bulk substances, this absolute moisture sensor can be fitted into containers and systems such as troughs, bunkers, distributors, augers, conveyors, bins and silos. This permits 24/7 moisture measurement of fibrous materials, sawdust, gravel, fly ash (mineral), wood chips (surface to 5 cm) feed grain, flour, pastes, seed, or similar bulk or flowing substances.
- PCE-MWM 240-B Rod sensor (custom length 500 ... 1500 mm)
- Lab analysis of your sample determines % error
- Measuring range: 0 ... 100%
- Material temperature range: -0 ... +80 °C (+41 ... +176 °F)
- Analog and digital signal output