Measuring range | 0.00 ... 14.00 pH |
Resolution | 0.01 pH |
Measurement accuracy | ± 0.01 pH |
Buffer detection pH measurement | pH 7.00, 4.01, 10.01 or pH 6.86, 4.00, 9.18 |
Temperature compensation pH measurement | Automatically -5 ... 60°C / 23 ... 140°F |
Buffer detection Temperature measuring range | 0.0 ... 60.0°C |
Offset detection pH electrode | ± 100 mV at pH 7.00 + 91.7 mV / -108.7 mV at pH 6.86 |
Slope pH electrode | ± 30% at pH 4.00, 4.01, 9.18, and 10.01 |
Input resistance | > 1012 Ω |
Water analysis meter: Technical data Conductivity | |
Measuring range | 0 μS / cm ... 20 mS / cm |
Resolution | Minimum 1 μS / cm |
Measurement accuracy | ± 1% of the measured value |
Reference temperature | 15.0 ... 25.0°C / 59 ... 77°F |
Temperature coefficient | 0.00 ... 4.00% |
Water analysis meter: Technical data TDS | |
Measuring range | 0 mg / l ... 20.00 g / l |
Resolution | at least 1 mg / l |
Measurement accuracy | ± 1% of the measured value |
Constant | 0.30 ... 1.00 |
Water analysis meter: Specifications Salinity | |
measuring range | 0.0 ... 10.0 ppt |
resolution | 0.1 ppt |
measurement accuracy | ± 1% of the measured value |
Water analysis meter: Technical data Temperature | |
Measuring range | -5.0 ... 60°C / 23 ... 140°F |
Resolution | -5.0 ... 60°C: 0.1°C / 23 ... 140°F: 0.18°F |
Measurement accuracy | -5.0 ... 60°C: ± 0.5°C /23 ... 140°F: ± 0.9°C |
Temperature sensor | Thermistor, 10 kΩ at 25°C / 77°F |
unit | °C or °F |
General technical data of the Water analysis meter | |
Power supply | 4 x LR44 battery |
Automatic shutdown | after about 10 minutes of inactivity |
Capacity Datalogger | 50 records |
Ambient temperature | 0.0 ... 50.0°C / 32 ... 122°F |
Ambient humidity | < 95% rh |
Casing | ABS, IP67 |
Dimensions | 44 x 200 x 25 mm / 1.7 x 7.9 x 1 in |
Weight | 110 g / < 1 lb |
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
Calibration Solution pH10. pH electrodes drift over time, causing measurement errors. To ensure high accuracy, we recommend regular calibration of pH meters.
- pH 10.00
- Dosing with certificate
- Various sizes can be selected!
ex. VAT, ex. delivery costs
Calibration Solution pH7. pH electrodes drift over time, causing measurement errors. To ensure high accuracy, we recommend regular calibration of pH meters.
- pH 7.01
- Dosing with certificate
- Various sizes can be selected!
ex. VAT, ex. delivery costs
Calibration Solution pH4, pH7 and pH10. pH electrodes drift over time, causing measurement errors. To ensure high accuracy, we recommend regular calibration of pH meters.
- pH 4, pH 7 and pH 10
- Dosing with certificate
- Various sizes can be selected!
ex. VAT, ex. delivery costs
Calibration Solution pH4. pH electrodes drift over time, causing measurement errors. To ensure high accuracy, we recommend regular calibration of pH meters.
- pH 4.01
- Dosing with certificate
- Various sizes can be selected!
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs