Technical specifications | ||
Measurement range | 0.00 to 14.00 pH -1999 to 0 to 1999 mV (only with the optional Redox electrode) 0.0 ... 65.0 °C or 32 ... 149 °F (only the temperature sensor) | |
Resolution | 0.01 pH 1 mV 0.1°C | |
Accuracy (at 20°C) | ± (0.02 pH + 2 digits) ± (0.5 % + 2 digits) ±0.5°C | |
Calibration | Automatic three-point calibration | |
Temperature compensation | automatic from 0 to 65°C or manual between 0 and 100°C removing the temperature sensor | |
Electrode | pH PE-03 electrode, 1 meter cable and BNC plug temperature range: 0 ... 60 ºC | |
Measurement rate | adjustable from 1 second up to 8 hours 59 min 59 sec | |
Display | LCD display: 52 x 38 mm | |
Memory | SD card from 1 ... 16 GB (2 GB memory card included) | |
Interface | RS-232 | |
Software | optional | |
Power supply | 6 x 1.5 V AA batteries / mains adapter 9 V (optional) | |
Operating conditions | 0 to 50°C max. 80% r.h. | |
Dimensions | 177 x 68 x 45 mm | |
Weight | 490 g |
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
Special pH probe:
- pH range: 0.00 ... 14.00 pH
- Zero point: 7.0 ± 0.5 pH
- Temperature range: 0 ... 60 ° C (32 ... 140 ° C)
- Electrode type: Ag / AgCL / KCL
- Length: 150 mm (6")
- Diameter: 12 mm (0.5")
- Connection: BNC
Applications:
- Cosmetics
- Paint
- Wastewater
- And more
ex. VAT, ex. delivery costs
Calibration Solution pH4, pH7 and pH10. pH electrodes drift over time, causing measurement errors. To ensure high accuracy, we recommend regular calibration of pH meters.
- pH 4, pH 7 and pH 10
- Dosing with certificate
- Various sizes can be selected!
ex. VAT, ex. delivery costs
Calibration Solution pH10. pH electrodes drift over time, causing measurement errors. To ensure high accuracy, we recommend regular calibration of pH meters.
- pH 10.00
- Dosing with certificate
- Various sizes can be selected!
ex. VAT, ex. delivery costs
Calibration Solution pH7. pH electrodes drift over time, causing measurement errors. To ensure high accuracy, we recommend regular calibration of pH meters.
- pH 7.01
- Dosing with certificate
- Various sizes can be selected!
ex. VAT, ex. delivery costs
Calibration Solution pH4. pH electrodes drift over time, causing measurement errors. To ensure high accuracy, we recommend regular calibration of pH meters.
- pH 4.01
- Dosing with certificate
- Various sizes can be selected!
ex. VAT, ex. delivery costs
Input voltage: 110 V AC, 60 Hz
Output voltage: DC 9 V
Output current: 0.8 A
Connector: US / North American style plug
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs