Voltmeter (DMM)

Voltmeter PCE-HVAC 6
US$ 92.00
ex. VAT, ex. delivery costs
The voltmeter was specially developed for the tradesman in the field of heating, ventilation and air conditioning technology. This voltmeter is ideal for many inspection and maintenance jobs in this area.

- Current measurement up to 1000 A
- Cover of the measuring sockets
- Voltage measurement up to 600V
- Temperature measurement via 2 thermocouples
Voltmeter PCE-ITM 20
US$ 499.00
ex. VAT, ex. delivery costs
This Voltmeter PCE-ITM 20 combines a versatile multimeter with an insulation tester. In addition to the usual measured quantities such as voltage, current and resistance, this Voltmeter PCE-ITM 20 is also equipped with a frequency and capacitance measurement.

- Automatic range selection
- Capacitance measurement
- Integrated isolation tester
- Internal memory
- To IEC 1010, CAT III 1000V, CAT IV 600V
- Frequency measurement
Voltmeter PCE-LCT 1-ICA incl. ISO Calibration Certificate
US$ 405.00
ex. VAT, ex. delivery costs
ISO Calibration
With the Voltmeter, it is possible to measure leakage currents in the range of up to 100A. Leakage occurs when a current flows through an electrical conductor that is not normally designed to conduct electricity. The Voltmeter captures these currents and displays them on the display. 

- Measurable electrical parameters: AC V, AC A, resistance
- Clamp diameter: 30 mm
- Operating temperature: -10 ... 50°C / 50 ... 122°F
- Current consumption: 10-mA
- Incl. ISO calibration certificate
Voltmeter PCE-CBA 10
US$ 33.00
ex. VAT, ex. delivery costs

The voltmeter PCE-CBA 10 can be used as a car battery tester. To test the battery, the voltmeter can measure, inter alia, the starting current to determine the capacity of the car battery in the range between 30 and 100 Ah.

- For 12V starter batteries
- Cold start current CCA:  100 ... 1700 A
- Battery capacity:  30 Ah ... 100 Ah
- Battery standards:  DIN, JIS, EN, IEC, SAE, GB & MCA

Voltmeter PCE-CM 5
US$ 38.00
ex. VAT, ex. delivery costs
The voltmeter is a multimeter with a multitude of different functions. Thus, with the voltmeter, current measurements up to 200 A AC can be carried out without contact. This current range of the voltmeter already covers a large range of current measurements. 

Measurement function:
- AC
- DC
- DC voltage
- AC voltage
- LowZ AC / DC
- Resistance
- Continuity test
- Diode test
- Capacities
- Temperature (type K)
- Frequency (with the current clamp)
- Frequency (during voltage measurement)
- frequency (direct measurement)
- Duty cycle
Voltmeter PCE-PI 10
US$ 39.00
ex. VAT, ex. delivery costs
The voltmeter is used to determine the direction of rotation of 3-phase voltage networks. Furthermore, the voltmeter is able to measure voltages up to 600V AC / DC. The rotating field direction is important for machines and plants.

- Measuring range: 75 ... 600V AC
- 3-phase rotating field detection
- AC / DC voltage measurement
- CAT III 600V
Voltmeter PCE-LT 12
US$ 79.00
ex. VAT, ex. delivery costs
No-Shopping
The voltmeter is a versatile measuring instrument. In addition to the standard voltage and current measurements, the voltmeter also has a network analysis. With this network analysis, the voltmeter can be used to check, for example, LAN connections for their correct wiring and function.

Measurement function:
- AC voltage
- DC voltage
- AC
- DC
- Resistance
- Diode measurement
- Continuity test
Clamp Voltmeter PCE-OC 5
US$ 92.00
ex. VAT, ex. delivery costs
The Clamp Voltmeter is suitable for service technicians, stationary use in repair departments in specialist shops and in laboratories. The Clamp Voltmeter is designed for current measurements up to 400 A AC.
 
Graphic display of  the measurement signal
- Oscilloscope mode
- memory function
 
Measurement parameters:
- DC voltage
- AC voltage
- AC
- frequency
- resistance
- capacity
- temperature
Voltmeter PCE-LT 15
US$ 92.00
ex. VAT, ex. delivery costs
The voltmeter PCE-LT 15 is a combination device which detects configuration errors in the network and can be used as a voltmeter at the same time. Thus, the periphery of a network can be quickly checked with the LAN tester. 

Measuring function:
- AC voltage: 750V
- DC voltage: 1000V
- Resistance: 4 MΩ
- Continuity test: 400 Ω
- Electrical safety: CAT III 600V
Voltmeter PCE-ODM 10
US$ 99.00
ex. VAT, ex. delivery costs
This PCE-ODM 10 voltmeter features both automatic and manual ranging and a dual OLED display. The measured values ​​are displayed on the OLED number display up to 6,000 digits and in the bar graph. 

Measuring function
- DC DC
- AC voltage AC (TRMS)
- AC + DC TRMS voltage
- DC DC
- AC AC (TRMS)
- 4 ... 20-mA %
- AC AC / Rogowski coil
- Resistance
- Frequency
- Duty cycle
- Capacity
- Temperature / thermocouple
Voltmeter PCE-DM 15
US$ 100.00
ex. VAT, ex. delivery costs
The Voltmeter is a multi-meter with extensive functions. In addition to the current and voltage resistance measurements, this multimeter can also be used to measure continuity and temperature with thermocouples.

Measuring function:
- DC voltage
- AC voltage
- Alternating current
- Resistance
- Capacity
- Frequency
- Type K temperature measurement
- Diode test
- Continuity test
Voltmeter PCE-DC1
US$ 102.00
ex. VAT, ex. delivery costs
No-Shopping

Mini Voltmeter for measuring AC current, AC voltage, DC current and frequency.


- AC current (50/60 Hz): 200 A / 0.1 A or 100 mA / ±3.0% + 8 digits
- DC current: 200 A / 0.1 A or 100 mA / ±2.8% + 8 digits
- AC test voltage (without contact): 100 VAC to 600 VAC 50 / 60 Hz
- Frequency: 40 to 50 Hz / 51 to 510 Hz/ 0.51 to 1 kHz

 

Voltmeter PCE-CBA 20
US$ 107.00
ex. VAT, ex. delivery costs
No-Shopping

The Voltmeter tests 12V and 24V starter batteries. The voltmeter checks the condition of the car battery via the battery voltage in the charging cycle, when starting or when idling. 

 

- Measurement object:  12V / 24V starter batteries

- Battery standards: DIN, JIS, EN, SAE

- Power supply: 9 ... 35V DC via test voltage

Voltmeter PCE-CM 3
US$ 119.00
ex. VAT, ex. delivery costs
The voltmeter is used for quick and easy AC measurements. For current measurement, the voltmeter is plugged over the live conductor. The voltmeter is particularly suitable for the measurement of alternating current in distributions and wherever circuits must not be interrupted.

- Digital Multimeters up to 200 A
- Compact dimensions
- Robust plastic housing
- Multimeter functions
- Safety conditions: IEC1010-1 (2001)
                             CAT II 1000V
                             CAT III 600V
Voltmeter PCE-OCM 10
US$ 132.00
ex. VAT, ex. delivery costs
The voltmeter is characterized by the OLED display. The OLED display on this voltmeter allows the display itself to be read in the dark, as it is self-luminous.

- Measurable up to 600 A
- Clamp with multimeter functions
- OLED display
- NCV function
- TRMS AC A
Voltmeter PCE-DC2
US$ 145.00
ex. VAT, ex. delivery costs

Digital Clamp Meter for measuring AC/DC current, AC voltage and resistance. This clamp meter is designed to indirectly detect AC/DC current and ohms. The clamp has white LEDs which illuminate the point of measurement and test the voltage without contact. Small dimensions of this device allow to take measurements in places with limited access. The clamp meter comes manufacturer calibrated and can optionally be certified according to ISO or standards.


- AC / DC current, voltage and resistance measurement
- 3 2/3-digit LCD display
- Power supply: 2 x 1.5V AAA battery
- Dimensions: 164 x 65 x 32 mm / 6.4 x 2.5 x 1.2 in

 

Voltmeter PCE-DC3
US$ 158.00
ex. VAT, ex. delivery costs
This voltmeter was developed for the indirect measurement of AC/DC currents as well as the frequency. A non-contact voltage tester function and a torch/flashlight for illuminating the measuring point have also been integrated into this voltmeter.

- AC/DC current, AC voltage and frequency measurement
- AC voltage test (contactless test):
   100 VAC to 600 VAC 50/60Hz 100 VAC to 600 VAC 50/60Hz
- DCA zero point function
Voltmeter PCE-DC 20
US$ 197.00
ex. VAT, ex. delivery costs
The voltmeter is a versatile measuring instrument for the determination of currents, voltages and many other electrical quantities. With a current clamp opening of 40 mm / 1.6 in, even cables with a larger diameter can be tested with the voltmeter.

Measurement functions
- DC power
- AC power
- DC voltage
- AC voltage
- Resistance
- Frequency (direct)
- Frequency (current clamp)