The HVAC Meter / HVACR Tester has a measuring range of -50 ... +760 °C and thus covers a wide temperature range. With an accuracy of ±2 % ±2 °C at 20 ... 760 °C, the HVAC Meter / HVACR Tester is a very precise measuring device. Two lasers are built into the HVAC Meter / HVACR Tester for better orientation of the measuring spot. Both lasers have an output power of <1 mW. To determine different surfaces with the HVAC Meter / HVACR Tester, the emission value can be set between 0.10 ... 1.00.
With the limit value alarm function on the HVAC Meter / HVACR Tester, a minimum temperature and a maximum temperature can be set individually. If the set limit value is exceeded or undershot during a measurement with the HVAC Meter / HVACR Tester, this is immediately signalled acoustically and visually by the HVAC Meter / HVACR Tester.
To switch on the HVAC Meter / HVACR Tester, the measuring button must be pressed. The measurement is then immediately taken by the HVAC Meter / HVACR Tester. If the button is released, the last value remains on the HVAC Meter / HVACR Tester display until a new measurement is taken. The HVAC Meter / HVACR Tester can optionally be equipped with an ISO calibration certificate.
| Infrared temperature | |
| Measuring range | -50 ... +20 °C |
| Resolution | 0,1 °C |
| Accuracy | ±3°C |
| Infrared temperature | |
| Measuring range | 20 ... 760 °C |
| Resolution | 0,1 °C |
| Accuracy | ±(2% of reading ±2°C) |
| Infrared temperature | |
| Measuring range | -58 ... +68 °F |
| Resolution | 0,1 °F |
| Accuracy | ±5.4 °F |
| Infrared temperature | |
| Measuring range | 68 ... 1400 °F |
| Resolution | 0,1 °F |
| Accuracy | ±3.6 °F |
| General technical data | |
| Repeat accuracy | ±1°C / ±1.8°F |
| Measuring rate | 2 Hz |
| Measurement spot | 12:1 |
| Laser | Class 2 <1mW |
| Emissivity from/to | 0.1 ... 1 |
| Spectral range | 8 ... 14 µm |
| Wavelength range | 630 ... 670 mm |
| Menu language | English, English (GB) |
| Protection class (device) | IP20 |
| Power supply | batteries |
| (Rechargeable) battery | 1 x 1,5 V 9V block , Alkali-manganese |
| Capacity | 640 mAh |
| Operating conditions | 0 ... 50 °C , 0 ... 90 % RH |
| Storage conditions | -10 ... 60 °C , 0 ... 80 % RH |
| Dimensions ( L x W x H ) | 175 x 75 x 35 mm |
| Weight | 132 g |