Bilingual Technical Support (EN / ES)
Public Service, Military and First Responder Discount
30 Day Return Policy
2 Year Warranty
The Multimeter / TRMS Multimeter provides precise measurements for a variety of parameters, including AC and DC voltage, direct and alternating current, frequency, resistance, capacitance and temperature. Our Multimeter / TRMS Multimeter has a hold function for saving measurement results as well as non-contact voltage detection (NCV).
The device enables both automatic and manual measurement range selection and is equipped with an easy-to-read 2.8-inch LCD with backlight. With a sampling rate of three measurements per second, it delivers quick results and switches off automatically after five minutes of inactivity to extend the battery life. In addition, the Multimeter / TRMS Multimeter offers a dual display: a bar graph for quick visual assessments and a numerical display for precise readings.
The Multimeter / TRMS Multimeter is powered by two 1.5 V batteries and is designed for easy one-handed operation. The compact dimensions of 140 x 70 x 35 mm make the Multimeter / TRMS Multimeter a practical tool for everyday use by electricians and hardware developers as well as in other technical applications.
| Direct voltage DC | |
| Measurement range up to | 0 ... 9,999 mV | 
| Resolution | 0,001 mV | 
| Accuracy | ±(0.5 % of Rd +3 digits) | 
| Direct voltage DC | |
| Measurement range up to | 10 ... 99,99 mV | 
| Resolution | 0,01 mV | 
| Accuracy | ±(0.5 % of Rd +3 digits) | 
| Direct voltage DC | |
| Measurement range up to | 100 ... 999,9 mV | 
| Resolution | 0,1 mV | 
| Accuracy | ±(0.5 % of Rd +3 digits) | 
| Direct voltage DC | |
| Measurement range up to | 1 ... 9,999 V | 
| Resolution | 0,001 V | 
| Accuracy | ±(0.5 % of Rd +3 digits) | 
| Direct voltage DC | |
| Measurement range up to | 10 ... 99,99 V | 
| Resolution | 0,01 V | 
| Accuracy | ±(0.5 % of Rd +3 digits) | 
| Direct voltage DC | |
| Measurement range up to | 100 ... 999,9 V | 
| Resolution | 0,1 V | 
| Accuracy | ±(0.5 % of Rd +3 digits) | 
| Direct current DC | |
| Measurement range up to | 0 ... 9999 µA | 
| Resolution | 1 µA | 
| Accuracy | ±(0.8 % of Rd +3 digits) | 
| Direct current DC | |
| Measurement range up to | 10 ... 99,99 mA | 
| Resolution | 0,01 mA | 
| Accuracy | ±(0.8 % of Rd +3 digits) | 
| Direct current DC | |
| Measurement range up to | 100 ... 999,9 mA | 
| Resolution | 0,1 mA | 
| Accuracy | ±(1 % of Rd +3 digits) | 
| Direct current DC | |
| Measurement range up to | 1 ... 9,999 A | 
| Resolution | 0,001 A | 
| Accuracy | ±(1 % of Rd +3 digits) | 
| Capacity | |
| Measurement range up to | 0 ... 9,999 nF | 
| Resolution | 0,001 nF | 
| Accuracy | ±(5.0 % of Rd +20 digits) | 
| Capacity | |
| Measurement range up to | 10 ... 99,99 nF | 
| Resolution | 0,01 nF | 
| Accuracy | ±(2.0 % of Rd +5 digits) | 
| Capacity | |
| Measurement range up to | 100 ... 999,9 nF | 
| Resolution | 0,1 nF | 
| Accuracy | ±(2.0 % of Rd +5 digits) | 
| Capacity | |
| Measurement range up to | 1 ... 9,999 µF | 
| Resolution | 0,001 µF | 
| Accuracy | ±(2.0 % of Rd +5 digits) | 
| Capacity | |
| Measurement range up to | 10 ... 99,99 µF | 
| Resolution | 0,01 µF | 
| Accuracy | ±(2.0 % of Rd +5 digits) | 
| Capacity | |
| Measurement range up to | 100 ... 999,9 µF | 
| Resolution | 0,1 µF | 
| Accuracy | ±(2.0 % of Rd +5 digits) | 
| Capacity | |
| Measurement range up to | 1 ... 9,999 mF | 
| Resolution | 0,001 mF | 
| Accuracy | ±(5.0 % of Rd +5 digits) | 
| AC voltage | |
| Measurement range up to | 0 ... 9,999 mV | 
| Resolution | 0,001 mV | 
| Accuracy | ±(1 % of Rd +3 digits) | 
| Frequency range | 40 ... 1000 Hz | 
| AC voltage | |
| Measurement range up to | 10 ... 99,99 mV | 
| Resolution | 0,01 mV | 
| Accuracy | ±(1 % of Rd +3 digits) | 
| Frequency range | 40 ... 1000 Hz | 
| AC voltage | |
| Measurement range up to | 100 ... 999,9 mV | 
| Resolution | 0,1 mV | 
| Accuracy | ±(1 % of Rd +3 digits) | 
| Frequency range | 40 ... 1000 Hz | 
| AC voltage | |
| Measurement range up to | 1 ... 9,999 V | 
| Resolution | 0,001 V | 
| Accuracy | ±(1 % of Rd +3 digits) | 
| Frequency range | 40 ... 1000 Hz | 
| AC voltage | |
| Measurement range up to | 10 ... 99,99 V | 
| Resolution | 0,01 V | 
| Accuracy | ±(1 % of Rd +3 digits) | 
| Frequency range | 40 ... 1000 Hz | 
| AC voltage | |
| Measurement range up to | 100 ... 750 V | 
| Resolution | 0,1 V | 
| Accuracy | ±(1 % of Rd +3 digits) | 
| Frequency range | 40 ... 1000 Hz | 
| Alternating current AC | |
| Measurement range up to | 0 ... 9999 µA | 
| Resolution | 1 µA | 
| Accuracy | ±(1 % of Rd +3 digits) | 
| Frequency range | 40 ... 1000 Hz | 
| Alternating current AC | |
| Measurement range up to | 10 ... 99,99 mA | 
| Resolution | 0,01 mA | 
| Accuracy | ±(1 % of Rd +3 digits) | 
| Frequency range | 40 ... 1000 Hz | 
| Alternating current AC | |
| Measurement range up to | 100 ... 999,9 mA | 
| Resolution | 0,1 mA | 
| Accuracy | ±(1.2 % of Rd +3 digits) | 
| Frequency range | 40 ... 1000 Hz | 
| Alternating current AC | |
| Measurement range up to | 1 ... 9,999 A | 
| Resolution | 0,001 A | 
| Accuracy | ±(1.2 % of Rd +3 digits) | 
| Frequency range | 40 ... 1000 Hz | 
| Resistance | |
| Measurement range up to | 0 ... 99,99 Ω | 
| Resolution | 0,01 Ω | 
| Accuracy | ±(1 % of Rd +3 digits) | 
| Resistance | |
| Measurement range up to | 100 ... 999,9 Ω | 
| Resolution | 0,1 Ω | 
| Accuracy | ±(0.5 % of Rd +3 digits) | 
| Resistance | |
| Measurement range up to | 1 ... 9,999 kΩ | 
| Resolution | 0,001 kΩ | 
| Accuracy | ±(0.5 % of Rd +3 digits) | 
| Resistance | |
| Measurement range up to | 10 ... 99,99 kΩ | 
| Resolution | 0,01 kΩ | 
| Accuracy | ±(0.5 % of Rd +3 digits) | 
| Resistance | |
| Measurement range up to | 100 ... 999,9 kΩ | 
| Resolution | 0,1 kΩ | 
| Accuracy | ±(0.5 % of Rd +3 digits) | 
| Resistance | |
| Measurement range up to | 1 ... 9,999 M Ω | 
| Resolution | 0,001 M Ω | 
| Accuracy | ±(1.5 % of Rd +3 digits) | 
| Resistance | |
| Measurement range up to | 10 ... 99,99 M Ω | 
| Resolution | 0,01 M Ω | 
| Accuracy | ±(3.0 % of Rd +5 digits) | 
| Duty cycle | |
| Measurement range up to | 1 ... 99 % | 
| Resolution | 0,1 % | 
| Accuracy | ±(0.1 % of Rd +2 digits) | 
| Frequency | |
| Measurement range up to | 0 ... 99,99 Hz | 
| Resolution | 0,01 Hz | 
| Accuracy | ±(0.1 % of Rd +2 digits) | 
| Frequency | |
| Measurement range up to | 100 ... 999,9 Hz | 
| Resolution | 0,1 Hz | 
| Accuracy | ±(0.1 % of Rd +2 digits) | 
| Frequency | |
| Measurement range up to | 1 ... 9,999 kHz | 
| Resolution | 0,001 kHz | 
| Accuracy | ±(0.1 % of Rd +2 digits) | 
| Frequency | |
| Measurement range up to | 10 ... 99,99 kHz | 
| Resolution | 0,01 kHz | 
| Accuracy | ±(0.1 % of Rd +2 digits) | 
| Frequency | |
| Measurement range up to | 100 ... 999,9 kHz | 
| Resolution | 0,1 kHz | 
| Accuracy | ±(0.1 % of Rd +2 digits) | 
| Frequency | |
| Measurement range up to | 1 ... 5 MHz | 
| Resolution | 0,001 MHz | 
| Accuracy | ±(0.1 % of Rd +2 digits) | 
| Temperature | |
| Measurement range up to | -20 ... +1000 °C | 
| Resolution | 1 °C | 
| Accuracy | ±(2.5 % of Rd +5 digits) | 
| Temperature | |
| Measurement range up to | -4 ... +1832 °F | 
| Resolution | 1 °F | 
| Accuracy | ±(2.5 % of Rd +5 digits) | 
| General technical data | |
| Measuring functions | HOLD | 
| Display type | LCD with backlight | 
| Display size | 2,8 Inch | 
| Measuring rate | 3 x per second | 
| Automatic power-off | 5 min | 
| Safety standard | CAT II 1000 V, CAT III 600 V | 
| Measurement range selection | Automatic, Manual | 
| Menu language | English, English (GB) | 
| Protection class (device) | IP20 | 
| Weight | 175 g | 
| Operating conditions | 0 ... 40 °C , 0 ... 75 % RH | 
| Storage conditions | -20 ... 60 °C , 0 ... 80 % RH | 
| (Rechargeable) battery | 2 x 1,5 V AA battery , Alkali-manganese | 
| Capacity | 3000 mAh | 
| Dimensions ( L x W x H ) | 140 x 70 x 35 mm |