Bilingual Technical Support (EN / ES)
Public Service, Military and First Responder Discount
30 Day Return Policy
2 Year Warranty
Free Standard Shipping (US)
The Digital Multimeter provides precise measurements for a variety of parameters, including AC and DC voltage, direct and alternating current, frequency, resistance, capacitance and temperature. Our Digital Multimeter has a hold function for saving measurement results as well as non-contact voltage detection (NCV).
The device enables both automatic and manual measurement range selection and is equipped with an easy-to-read 2.8-inch LCD with backlight. With a sampling rate of three measurements per second, it delivers quick results and switches off automatically after five minutes of inactivity to extend the battery life. In addition, the Digital Multimeter offers a dual display: a bar graph for quick visual assessments and a numerical display for precise readings.
The Digital Multimeter is powered by two 1.5 V batteries and is designed for easy one-handed operation. The compact dimensions of 140 x 70 x 35 mm make the Digital Multimeter a practical tool for everyday use by electricians and hardware developers as well as in other technical applications.
Direct voltage DC | |
Measurement range up to | 0 ... 9,999 mV |
Resolution | 0,001 mV |
Accuracy | ±(0.5 % of Rd +3 digits) |
Direct voltage DC | |
Measurement range up to | 10 ... 99,99 mV |
Resolution | 0,01 mV |
Accuracy | ±(0.5 % of Rd +3 digits) |
Direct voltage DC | |
Measurement range up to | 100 ... 999,9 mV |
Resolution | 0,1 mV |
Accuracy | ±(0.5 % of Rd +3 digits) |
Direct voltage DC | |
Measurement range up to | 1 ... 9,999 V |
Resolution | 0,001 V |
Accuracy | ±(0.5 % of Rd +3 digits) |
Direct voltage DC | |
Measurement range up to | 10 ... 99,99 V |
Resolution | 0,01 V |
Accuracy | ±(0.5 % of Rd +3 digits) |
Direct voltage DC | |
Measurement range up to | 100 ... 999,9 V |
Resolution | 0,1 V |
Accuracy | ±(0.5 % of Rd +3 digits) |
Direct current DC | |
Measurement range up to | 0 ... 9999 µA |
Resolution | 1 µA |
Accuracy | ±(0.8 % of Rd +3 digits) |
Direct current DC | |
Measurement range up to | 10 ... 99,99 mA |
Resolution | 0,01 mA |
Accuracy | ±(0.8 % of Rd +3 digits) |
Direct current DC | |
Measurement range up to | 100 ... 999,9 mA |
Resolution | 0,1 mA |
Accuracy | ±(1 % of Rd +3 digits) |
Direct current DC | |
Measurement range up to | 1 ... 9,999 A |
Resolution | 0,001 A |
Accuracy | ±(1 % of Rd +3 digits) |
Capacity | |
Measurement range up to | 0 ... 9,999 nF |
Resolution | 0,001 nF |
Accuracy | ±(5.0 % of Rd +20 digits) |
Capacity | |
Measurement range up to | 10 ... 99,99 nF |
Resolution | 0,01 nF |
Accuracy | ±(2.0 % of Rd +5 digits) |
Capacity | |
Measurement range up to | 100 ... 999,9 nF |
Resolution | 0,1 nF |
Accuracy | ±(2.0 % of Rd +5 digits) |
Capacity | |
Measurement range up to | 1 ... 9,999 µF |
Resolution | 0,001 µF |
Accuracy | ±(2.0 % of Rd +5 digits) |
Capacity | |
Measurement range up to | 10 ... 99,99 µF |
Resolution | 0,01 µF |
Accuracy | ±(2.0 % of Rd +5 digits) |
Capacity | |
Measurement range up to | 100 ... 999,9 µF |
Resolution | 0,1 µF |
Accuracy | ±(2.0 % of Rd +5 digits) |
Capacity | |
Measurement range up to | 1 ... 9,999 mF |
Resolution | 0,001 mF |
Accuracy | ±(5.0 % of Rd +5 digits) |
AC voltage | |
Measurement range up to | 0 ... 9,999 mV |
Resolution | 0,001 mV |
Accuracy | ±(1 % of Rd +3 digits) |
Frequency range | 40 ... 1000 Hz |
AC voltage | |
Measurement range up to | 10 ... 99,99 mV |
Resolution | 0,01 mV |
Accuracy | ±(1 % of Rd +3 digits) |
Frequency range | 40 ... 1000 Hz |
AC voltage | |
Measurement range up to | 100 ... 999,9 mV |
Resolution | 0,1 mV |
Accuracy | ±(1 % of Rd +3 digits) |
Frequency range | 40 ... 1000 Hz |
AC voltage | |
Measurement range up to | 1 ... 9,999 V |
Resolution | 0,001 V |
Accuracy | ±(1 % of Rd +3 digits) |
Frequency range | 40 ... 1000 Hz |
AC voltage | |
Measurement range up to | 10 ... 99,99 V |
Resolution | 0,01 V |
Accuracy | ±(1 % of Rd +3 digits) |
Frequency range | 40 ... 1000 Hz |
AC voltage | |
Measurement range up to | 100 ... 750 V |
Resolution | 0,1 V |
Accuracy | ±(1 % of Rd +3 digits) |
Frequency range | 40 ... 1000 Hz |
Alternating current AC | |
Measurement range up to | 0 ... 9999 µA |
Resolution | 1 µA |
Accuracy | ±(1 % of Rd +3 digits) |
Frequency range | 40 ... 1000 Hz |
Alternating current AC | |
Measurement range up to | 10 ... 99,99 mA |
Resolution | 0,01 mA |
Accuracy | ±(1 % of Rd +3 digits) |
Frequency range | 40 ... 1000 Hz |
Alternating current AC | |
Measurement range up to | 100 ... 999,9 mA |
Resolution | 0,1 mA |
Accuracy | ±(1.2 % of Rd +3 digits) |
Frequency range | 40 ... 1000 Hz |
Alternating current AC | |
Measurement range up to | 1 ... 9,999 A |
Resolution | 0,001 A |
Accuracy | ±(1.2 % of Rd +3 digits) |
Frequency range | 40 ... 1000 Hz |
Resistance | |
Measurement range up to | 0 ... 99,99 Ω |
Resolution | 0,01 Ω |
Accuracy | ±(1 % of Rd +3 digits) |
Resistance | |
Measurement range up to | 100 ... 999,9 Ω |
Resolution | 0,1 Ω |
Accuracy | ±(0.5 % of Rd +3 digits) |
Resistance | |
Measurement range up to | 1 ... 9,999 kΩ |
Resolution | 0,001 kΩ |
Accuracy | ±(0.5 % of Rd +3 digits) |
Resistance | |
Measurement range up to | 10 ... 99,99 kΩ |
Resolution | 0,01 kΩ |
Accuracy | ±(0.5 % of Rd +3 digits) |
Resistance | |
Measurement range up to | 100 ... 999,9 kΩ |
Resolution | 0,1 kΩ |
Accuracy | ±(0.5 % of Rd +3 digits) |
Resistance | |
Measurement range up to | 1 ... 9,999 M Ω |
Resolution | 0,001 M Ω |
Accuracy | ±(1.5 % of Rd +3 digits) |
Resistance | |
Measurement range up to | 10 ... 99,99 M Ω |
Resolution | 0,01 M Ω |
Accuracy | ±(3.0 % of Rd +5 digits) |
Duty cycle | |
Measurement range up to | 1 ... 99 % |
Resolution | 0,1 % |
Accuracy | ±(0.1 % of Rd +2 digits) |
Frequency | |
Measurement range up to | 0 ... 99,99 Hz |
Resolution | 0,01 Hz |
Accuracy | ±(0.1 % of Rd +2 digits) |
Frequency | |
Measurement range up to | 100 ... 999,9 Hz |
Resolution | 0,1 Hz |
Accuracy | ±(0.1 % of Rd +2 digits) |
Frequency | |
Measurement range up to | 1 ... 9,999 kHz |
Resolution | 0,001 kHz |
Accuracy | ±(0.1 % of Rd +2 digits) |
Frequency | |
Measurement range up to | 10 ... 99,99 kHz |
Resolution | 0,01 kHz |
Accuracy | ±(0.1 % of Rd +2 digits) |
Frequency | |
Measurement range up to | 100 ... 999,9 kHz |
Resolution | 0,1 kHz |
Accuracy | ±(0.1 % of Rd +2 digits) |
Frequency | |
Measurement range up to | 1 ... 5 MHz |
Resolution | 0,001 MHz |
Accuracy | ±(0.1 % of Rd +2 digits) |
Temperature | |
Measurement range up to | -20 ... +1000 °C |
Resolution | 1 °C |
Accuracy | ±(2.5 % of Rd +5 digits) |
Temperature | |
Measurement range up to | -4 ... +1832 °F |
Resolution | 1 °F |
Accuracy | ±(2.5 % of Rd +5 digits) |
General technical data | |
Measuring functions | HOLD |
Display type | LCD with backlight |
Display size | 2,8 Inch |
Measuring rate | 3 x per second |
Automatic power-off | 5 min |
Safety standard | CAT II 1000 V, CAT III 600 V |
Measurement range selection | Automatic, Manual |
Menu language | English, English (GB) |
Protection class (device) | IP20 |
Weight | 175 g |
Operating conditions | 0 ... 40 °C , 0 ... 75 % RH |
Storage conditions | -20 ... 60 °C , 0 ... 80 % RH |
(Rechargeable) battery | 2 x 1,5 V AA battery , Alkali-manganese |
Capacity | 3000 mAh |
Dimensions ( L x W x H ) | 140 x 70 x 35 mm |