Description

Aerosol meter / Aerosol measuring device / measures temperature, humidity, air pressure and CO2 content of the air / traffic light function / audible and visual alarm / adjustable alarm limits / software

The Aerosol meter / Aerosol measuring device is specially designed for long-term monitoring of climatic conditions in offices, classrooms or lecture halls, for example. The Aerosol meter / Aerosol measuring device has various sensors for this purpose. Among other things, the Aerosol meter / Aerosol measuring device has a carbon dioxide sensor up to 40000 ppm, a temperature sensor with a measurement range between 0 ... 50 °C, an ambient humidity sensor with a measurement range of 0 ... 100 % RH and a barometer with a measurement range of 300 ... 1250 hPa. This means that the Aerosol meter / Aerosol measuring device can be used in many applications thanks to its sensor diversity. The measured values are shown directly on the e-paper display of the Aerosol meter / Aerosol measuring device. The CO2 content of the ambient air is also displayed in the form of a traffic light.

During the measurement, the Aerosol meter / Aerosol measuring device can automatically record the measured values. The measured values are saved on the micro SD card as a .csv file. This allows the measurement data recorded by the Aerosol meter / Aerosol measuring device to be imported directly into a company's own database. With the help of the software, the measurement data from the Aerosol meter / Aerosol measuring device can be displayed graphically and in tabular form.
The Aerosol meter / Aerosol measuring device has an alarm function. This alarm mode can be used to set limit values for the individual sensors. As soon as the set limit value is reached on the Aerosol meter / Aerosol measuring device, this is indicated acoustically by a sound and visually by the alarm LED. Once the Aerosol meter / Aerosol measuring device falls below the limit value again, the alarm switches off automatically.

The measured values are shown numerically on the 2.7" display of the Aerosol meter / Aerosol measuring device. For better analysis of the last measured values, the display can be switched to a histogram display. The energy-saving e-paper display enables a long battery life of the Aerosol meter / Aerosol measuring device. Depending on the settings, the battery can operate the Aerosol meter / Aerosol measuring device device for approx. 10 months before it needs to be recharged. In addition to being powered by the built-in rechargeable battery, the Aerosol meter / Aerosol measuring device can also be operated continuously via the USB-C charging cable.


Highlights

- CO2 measurement range up to 40000 ppm
- temperature and humidity sensor
- atmospheric pressure display
- carbon dioxide and absolute pressure sensor
- .csv file format
- e-paper display with histogram display
- traffic light function for carbon dioxide
- battery life of up to 10 months
- 32 GB data memory
- alarm limit values

Specification

CO² 
Measuring range  0 ... 40000 ppm
Resolution  1 ppm
Accuracy  ±(40 ppm +5 % of Rd) @ 400 ... 5000 ppm @ 25 ºC / 77 ºF
  
Air pressure 
Measuring range  300 ... 1250 hPa
Resolution  0,1 hPa
Accuracy  ±50 hPa @ -20 ... 75 ºC / 700 ... 1100 hPa
  
Relative humidity 
Measuring range  0 ... 80 % RH
Resolution  0,1 % RH
Accuracy  ±1.5 % RH
  
Relative humidity 
Measuring range  80 ... 100 % RH
Resolution  0,1 % RH
Accuracy  ±2 % RH
  
Temperature 
  
Temperature 
Measuring range  0 ... 20 °C
Resolution  0,1 °C
Accuracy  ±0.8 °C
  
Temperature 
Measuring range  20 ... 50 °C
Resolution  0,1 °C
Accuracy  ±0.8 ºC
  
Temperature 
Measuring range  32 ... 60 °F
Resolution  0,1 °F
Accuracy  ±0.8 ºF
  
Temperature 
Measuring range  68 ... 122 °F
Resolution  0,1 °F
Accuracy  ±0.8 °F
  
General technical data 
Display type  E-paper
Display size  2,7 Inch
Storage medium  Micro SD card
Storage capacity  32 GB
Interface  USB-C
Operating time  10 Month(s)
Operating time additional information  10 months when measuring intervals are:
-temperature: 24 hours
-ambient humidity: 24 hours
-atmospheric pressure: 24 hours
-CO2: 24 hours
Alarm  optical, Acoustic
Menu language  English, Dutch, French, German, Italian, Polish, Spanish, Turkish
Protection class (device)  IP30
Power supply  5 V/1.5 A
(Rechargeable) battery  1 x 7,4 V 18650 , Lithium-ion battery
Capacity  3400 mAh
Performance  25,16 Wh
Operating conditions  0 ... 50 °C , 0 ... 100 % RH
Storage conditions  -20 ... 60 °C , 0 ... 100 % RH
Dimensions ( L x W x H )  130 x 90 x 40 mm
Weight  280 g

Delivery Scope

1 x Aerosol meter / Aerosol measuring device PCE-AQD 50A
1 x USB-C charging cable
1 x 32 GB micro SD memory card incl. adaptor
1 x wall mounting set
1 x software