Zum Hauptinhalt springen
Condition Monitoring Sound Level Meter PCE-325-ICA incl. ISO-calibration certificate
US$ 286.00
ex. VAT, ex. delivery costs
ISO Calibration
Our condition monitoring sound level meter records and visualizes sound levels in the range from 30 to 130 dB. The condition monitoring sound level meter has three manual measuring ranges and an automatic measuring range mode.

  • Measurement range 30 … 130 dB
  • Resolution 0.1 dB
  • Accuracy ±1.5 dB
  • Frequency 31.5 … 8,000 Hz
  • Class 2 microphone
  • Standard(s): IEC 61672-1 (Class II)
  •  incl. ISO-calibration certificate
Condition Monitoring Sound Level Meter PCE-322A
US$ 260.00
ex. VAT, ex. delivery costs
Topseller

The condition monitoring sound level meter is a handheld, portable, professional Class II sound pressure level (SPL) meter or decibel (dB) meter with built-in data-logging or data-recording functionality. Thus, the condition monitoring sound level meter is ideal for real-time noise measurement as well as for long-term noise exposure monitoring over time.


  • Sound measuring range: 30 …130 dB
  • Resolution: 0.1 dB
  • Accuracy: ±1.4 dB
  • Memory: Stores up to 32,700 readings
  • Sampling rate: 2 times per second
  • ISO calibration available as an option

 

Condition Monitoring Thermometer PCE-T 394-ICA incl. ISO-calibration certificate
US$ 294.00
ex. VAT, ex. delivery costs
ISO Calibration
The digital Condition Monitoring Thermometer offers precise temperature monitoring of multiple measuring points. With a measuring range of -210 to 1370 °C and support for thermocouple types K and J, it enables accurate measurements in different environments. The 4 input channels of the Condition Monitoring Thermometer enable simultaneous monitoring of multiple measuring points, making this Condition Monitoring Thermometer ideal for complex applications.

  • Measuring range -210 … 1370 °C
  • Resolution: 0.1 °C/ <1000, 1 °C >1000,
  • Accuracy: ±0.2 % of Mw.+1 °C above -100 °C
  • Thermocouple types K and J
  • 4 input channels
  • Memory for 32000 data records
  • incl. software
    incl. ISO-calibration certificate
Noise Meter / Sound Meter PCE-325-ICA incl. ISO-calibration certificate
US$ 286.00
ex. VAT, ex. delivery costs
ISO Calibration
Our noise meter / sound meter records and visualizes sound levels in the range from 30 to 130 dB. The noise meter / sound meter has three manual measuring ranges and an automatic measuring range mode.

  • Measurement range 30 … 130 dB
  • Resolution 0.1 dB
  • Accuracy ±1.5 dB
  • Frequency 31.5 … 8,000 Hz
  • Class 2 microphone
  • Standard(s): IEC 61672-1 (Class II)
  •  incl. ISO-calibration certificate
Condition Monitoring Class 2 Sound Level Data Logger PCE-SDL 1
US$ 296.00
ex. VAT, ex. delivery costs

PCE-SDL 1 is a Condition Monitoring Class 2 (type 2) Data-logging Sound Level Meter, sound pressure level (SPL) meter, noise meter or decibel (dB) meter used for long-term acoustic measurements.


  • Measuring range: 30 … 130 dB
  • Accuracy: ± 1.4 dB
  • Frequency: 31.5 Hz … 8 kHz
  • Frequency weighting: A and C
  • Memory: Stores up to 129,920 data sets or 36 hours at 1-sec interval
  • Includes USB interface and Windows-compatible software for data transfer to PC

 

Condition Monitoring Contact / Non-Contact Food Thermometer PCE-IR 90-ICA incl. ISO-Calibration Certificate
US$ 285.00
ex. VAT, ex. delivery costs
ISO Calibration
The condition monitoring contact / non-contact food thermometer is used to check the temperature of food. In addition to the surface temperature via the infrared sensor, the condition monitoring contact / non-contact food thermometer can also be used to determine the core temperature via the fold-out resistance temperature sensor.

  • Infrared measuring range: -40 … 300°C / -40 … 572°F
  • Sensor measuring range: -40 … 300°C / -40 … 572°F
  • Charging station with micro USB cable
  • Bluetooth interface
  • incl. ISO-Calibration Certificate
Sound Test Instrument PCE-325-ICA incl. ISO-calibration certificate
US$ 286.00
ex. VAT, ex. delivery costs
ISO Calibration
Our sound test instrument records and visualizes sound levels in the range from 30 to 130 dB. The sound test instrument has three manual measuring ranges and an automatic measuring range mode.

  • Measurement range 30 … 130 dB
  • Resolution 0.1 dB
  • Accuracy ±1.5 dB
  • Frequency 31.5 … 8,000 Hz
  • Class 2 microphone
  • Standard(s): IEC 61672-1 (Class II)
  •  incl. ISO-calibration certificate
Data Logging Sound Level Meter PCE-322A
US$ 260.00
ex. VAT, ex. delivery costs
Topseller

The PCE-322A is a handheld, portable, professional class 2 sound level meter or decibel (dB) meter with built-in data logging or data recording functionality. Thus, the PCE-322A is an ideal real-time noise measuring device as well as being useful for long-term noise exposure monitoring over time. The logged data can easily be downloaded to a PC or Portable for analysis.


  • Class 2
  • Sound measuring range: 30 …130 dB
  • Resolution: 0.1 dB
  • Accuracy: ±1.4 dB
  • Time weighting: A, C
  • Frequency weighting: Slow, fast
  • Memory: Stores up to 32,700 readings
  • Sampling rate: 2 times per second
  • ISO calibration available as an option

Class 2 Data-Logging Sound Level Meter PCE-SDL 1
US$ 296.00
ex. VAT, ex. delivery costs

PCE-SDL 1 is a class 2 (type 2) data logging sound level meter, sound pressure level (SPL) meter, noise meter or decibel (dB) meter used for long-term acoustic measurements. The instrument is equipped with a USB interface for downloading the logged data to a PCE, laptop or tablet.

  • Class 2
  • Measuring range: 30 … 130 dB
  • Accuracy: ± 1.4 dB
  • Frequency: 31.5 Hz … 8 kHz
  • Frequency weighting: A and C
  • Memory: Stores up to 129,920 data sets or 36 hours at 1-sec interval
  • Includes USB interface and PC-compatible software for data transfer

Data Logger for Temperature and Humidity PCE-HT 70-ICA incl ISO Calibration Cert
US$ 297.00
ex. VAT, ex. delivery costs
ISO Calibration

The data logger for temperature and humidity records the air temperature and humidity and stores them internally. The compact data logger for temperature and humidity with a large memory (up to a maximum of 16,000 values) is primarily used for long-term registration, for example in the food sector (e.g. refrigerated counters in supermarkets, refrigerated transport, warehouses) or in the industrial sector (heating and cooling processes, machine temperatures, product warehouses…)

  • Measuring range temperature: -40 … 85 °C / -40 … 185 °F
  • Measuring range rel. humidity: 0 … 100%
  • Max. 16,000 data records can be saved
  • Export to software possible
  • 450 day running time
  • Adjustable storage rate from 1 second
  • incl. ISO Calibration Certificate

Humidity / Temperature Data Logger PCE-HT 70-ICA incl. ISO Calibration Cert.
US$ 297.00
ex. VAT, ex. delivery costs
ISO Calibration

The humidity / temperature data logger records the air temperature and humidity and stores them internally. The compact humidity / temperature data logger with a large memory (up to a maximum of 16,000 values) is primarily used for long-term registration, for example in the food sector (e.g. refrigerated counters in supermarkets, refrigerated transport, warehouses) or in the industrial sector (heating and cooling processes, machine temperatures, product warehouses…)

  • Measuring range temperature: -40 … 85 °C / -40 … 185 °F
  • Measuring range rel. humidity: 0 … 100%
  • Max. 16,000 data records can be saved
  • Export to software possible
  • 450 day running time
  • Adjustable storage rate from 1 second
  • incl. ISO Calibration Certificate

Environmental Meter PCE-325-ICA incl. ISO-calibration certificate
US$ 286.00
ex. VAT, ex. delivery costs
ISO Calibration
Our environmental meter records and visualizes sound levels in the range from 30 to 130 dB. The environmental meter has three manual measuring ranges and an automatic measuring range mode.

  • Measurement range 30 … 130 dB
  • Resolution 0.1 dB
  • Accuracy ±1.5 dB
  • Frequency 31.5 … 8,000 Hz
  • Class 2 microphone
  • Standard(s): IEC 61672-1 (Class II)
  •  incl. ISO-calibration certificate
SPL Meter PCE-325-ICA incl. ISO-calibration certificate
US$ 286.00
ex. VAT, ex. delivery costs
ISO Calibration
Our SPL meter records and visualizes sound levels in the range from 30 to 130 dB. The SPL meter has three manual measuring ranges and an automatic measuring range mode.

  • Measurement range 30 … 130 dB
  • Resolution 0.1 dB
  • Accuracy ±1.5 dB
  • Frequency 31.5 … 8,000 Hz
  • Class 2 microphone
  • Standard(s): IEC 61672-1 (Class II)
  •  incl. ISO-calibration certificate
Sound Level Indicator PCE-EM 883
US$ 294.00
ex. VAT, ex. delivery costs
Our multifunctional sound level indicator PCE-EM 883 combines all important features for measuring the ambient conditions in one device. The sound level indicator is designed as fast as possible to determine as many parameters as possible. Due to the large number of external sensors that the sound level indicator brings with it, such fast and precise measurements are possible.

  • Measurement of all relevant environmental parameters
  • Wind speed
  • Temperature
  • Humidity
  • Sound level
  • Light
  • High accuracy
  • MIN, MAX, HOLD function
Decibel Meter PCE-325-ICA incl. ISO-calibration certificate
US$ 286.00
ex. VAT, ex. delivery costs
ISO Calibration
Our data logger records and visualizes sound levels in the range from 30 to 130 dB. The data logger has three manual measuring ranges and an automatic measuring range mode.

  • Measurement range 30 … 130 dB
  • Resolution 0.1 dB
  • Accuracy ±1.5 dB
  • Frequency 31.5 … 8,000 Hz
  • Class 2 microphone
  • Standard(s): IEC 61672-1 (Class II)
  •  incl. ISO-calibration certificate
Environmental Tester PCE-325-ICA incl. ISO-calibration certificate
US$ 286.00
ex. VAT, ex. delivery costs
ISO Calibration
Our environmental tester records and visualizes sound levels in the range from 30 to 130 dB. The environmental tester has three manual measuring ranges and an automatic measuring range mode.

  • Measurement range 30 … 130 dB
  • Resolution 0.1 dB
  • Accuracy ±1.5 dB
  • Frequency 31.5 … 8,000 Hz
  • Class 2 microphone
  • Standard(s): IEC 61672-1 (Class II)
  •  incl. ISO-calibration certificate
HVAC Meter PCE-T 394-ICA incl. ISO-calibration certificate
US$ 294.00
ex. VAT, ex. delivery costs
ISO Calibration
The HVAC meter offers precise temperature monitoring of multiple measuring points. With a measuring range of -210 to 1370 °C and support for thermocouple types K and J, it enables accurate measurements in different environments. The 4 input channels of the HVAC meter enable simultaneous monitoring of multiple measuring points, making this 4-channel thermometer ideal for complex applications.

  • Measuring range -210 … 1370 °C
  • Resolution: 0.1 °C/ <1000, 1 °C >1000,
  • Accuracy: ±0.2 % of Mw.+1 °C above -100 °C
  • Thermocouple types K and J
  • 4 input channels
  • Memory for 32000 data records
  • incl. software
    incl. ISO-calibration certificate
Sound Level Data Logger PCE-322A
US$ 260.00
ex. VAT, ex. delivery costs
Topseller

PCE-322A is a handheld, portable, professional Class II sound data logger or decibel (dB) meter with built-in data-logging or data-recording functionality. Thus, PCE-322A is ideal for real-time noise measurement as well as for long-term noise exposure monitoring over time.


  • Sound measuring range: 30 …130 dB
  • Resolution: 0.1 dB
  • Accuracy: ±1.4 dB
  • Memory: Stores up to 32,700 readings
  • Sampling rate: 2 times per second
  • ISO calibration available as an option

HVAC Meter PCE-HT 70-ICA incl. ISO Calibration Certificate
US$ 297.00
ex. VAT, ex. delivery costs
ISO Calibration

The HVAC meter records the air temperature and humidity and stores them internally. The compact HVAC meter with a large memory (up to a maximum of 16,000 values) is primarily used for long-term registration, for example in the food sector (e.g. refrigerated counters in supermarkets, refrigerated transport, warehouses) or in the industrial sector (heating and cooling processes, machine temperatures, product warehouses…)

  • Measuring range temperature: -40 … 85 °C / -40 … 185 °F
  • Measuring range rel. humidity: 0 … 100%
  • Max. 16,000 data records can be saved
  • Export to software possible
  • 450 day running time
  • Adjustable storage rate from 1 second
  • incl. ISO Calibration Certificate

Water Analysis Meter PCE-PH20-ICA incl. ISO calibration certificate
US$ 263.00
ex. VAT, ex. delivery costs
ISO Calibration
The water analysis meter was developed to directly determine the pH in aqueous media or water based solutions. Depending on the purpose of creating an aquarium, whether commercial, scientific (experimental and laboratory tests) or decorative, the most desirable pH level should be maintained to provide correct living conditions for the fish and other organisms.


  • Measuring range: 0.00 … 14.00 pH
  • Resolution: 0.01 pH
  • Waterproof (IP 67)
  • Data-Hold function
  • Calibration: automatic, pH 4, 7 or 10
  • Aqueous media
  • Incl. ISO calibration certificate

HVAC Meter PCE-DC1-ICA Incl. ISO Calibration Certificate
US$ 274.00
ex. VAT, ex. delivery costs
ISO Calibration
This HVAC Meter was developed for the indirect acquisition of AC / DC currents as well as the frequency. A non-contact voltage tester function and a flashlight for illuminating the measuring point were also integrated in this HVAC Meter. 

  • AC / DC current, AC voltage and frequency measurement
  • Integrated measuring point illumination
  • Non-contact voltage tester
  • Automatic range selection
  • Forceps opening: 18 mm
  • Automatic switch-off
  • Incl. ISO calibration certificate
HVAC Meter PCE-675-ICA Incl. ISO Calibration Certificate incl. Type K
US$ 281.00
ex. VAT, ex. delivery costs
ISO Calibration
The HVAC meter PCE-675-ICA incl. ISO calibration certificate has a 13:1 spot-to-spot ratio and can accurately measure surface temperatures and ambient humidity over a very long distance. The HVAC meter is universally applicable.

Measuring function
  • Measuring range infrared: -50 … 550 °C
  • Thermoelement Type-K: -50 … 850 ºC 
  • Measuring range air temperature: -20 … 60 ºC
  • Measuring range humidity: 0 … 100 % r.H.
  • Measuring range dew point: -20 … 60 ºC
  • Measuring range wet bulb temp.: -20 … 60ºC 
  • Incl. ISO calibration certificate
Environmental Meter PCE-PH20-ICA incl. ISO calibration certificate
US$ 263.00
ex. VAT, ex. delivery costs
ISO Calibration
The environmental meter was developed to directly determine the pH in aqueous media or water based solutions. Depending on the purpose of creating an aquarium, whether commercial, scientific (experimental and laboratory tests) or decorative, the most desirable pH level should be maintained to provide correct living conditions for the fish and other organisms.


  • Measuring range: 0.00 … 14.00 pH
  • Resolution: 0.01 pH
  • Waterproof (IP 67)
  • Data-Hold function
  • Calibration: automatic, pH 4, 7 or 10
  • Aqueous media
  • Incl. ISO calibration certificate

pH Meter PCE-PH20-ICA incl. ISO calibration certificate
US$ 263.00
ex. VAT, ex. delivery costs
ISO Calibration
The pH meter was developed to directly determine the pH in aqueous media or water based solutions. Depending on the purpose of creating an aquarium, whether commercial, scientific (experimental and laboratory tests) or decorative, the most desirable pH level should be maintained to provide correct living conditions for the fish and other organisms.


  • Measuring range: 0.00 … 14.00 pH
  • Resolution: 0.01 pH
  • Waterproof (IP 67)
  • Data-Hold function
  • Calibration: automatic, pH 4, 7 or 10
  • Aqueous media
  • Incl. ISO calibration certificate

Water Analysis Meter PCE-PH20S-ICA incl. ISO calibration certificate
US$ 277.00
ex. VAT, ex. delivery costs
ISO Calibration

The water analysis meter is a straightforward device for determining the pH value of soil. The instrument has an external pH electrode with cable and it is waterproof (IP 67). The water analysis pH meter can be recalibrated by using the calibration solutions that are supplied with the device.


  • Measuring range: 0.00 … 14.00 pH
  • Resolution: 0.01 pH
  • waterproof (IP 67)
  • Data-Hold function
  • Calibration: automatic, pH 4, 7, or 10
  • pH electrode for piercing into Soil
  • Incl. ISO calibration certificate


  • *Care must be taken when inserting probe to not break it**
Temperature Meter PCE-T 394-ICA incl. ISO-calibration certificate
US$ 294.00
ex. VAT, ex. delivery costs
ISO Calibration
The temperature meter offers precise temperature monitoring of multiple measuring points. With a measuring range of -210 to 1370 °C and support for thermocouple types K and J, it enables accurate measurements in different environments. The 4 input channels of the temperature meter enable simultaneous monitoring of multiple measuring points, making this 4-channel thermometer ideal for complex applications.

  • Measuring range -210 … 1370 °C
  • Resolution: 0.1 °C/ <1000, 1 °C >1000,
  • Accuracy: ±0.2 % of Mw.+1 °C above -100 °C
  • Thermocouple types K and J
  • 4 input channels
  • Memory for 32000 data records
  • incl. software
    incl. ISO-calibration certificate
pH Meter PCE-PH20S-ICA incl. ISO calibration certificate
US$ 277.00
ex. VAT, ex. delivery costs
ISO Calibration

The soil pH meter is a straightforward device for determining the pH value of soil. The instrument has an external pH electrode with cable and it is waterproof (IP 67). The soil pH meter can be recalibrated by using the calibration solutions that are supplied with the device.


  • Measuring range: 0.00 … 14.00 pH
  • Resolution: 0.01 pH
  • waterproof (IP 67)
  • Data-Hold function
  • Calibration: automatic, pH 4, 7, or 10
  • pH electrode for piercing into Soil
  • Incl. ISO calibration certificate

  • *Care must be taken when inserting probe to not break it**
Environmental Meter PCE-PH20S-ICA incl. ISO calibration certificate
US$ 277.00
ex. VAT, ex. delivery costs
ISO Calibration

The soil environmental meter is a straightforward device for determining the pH value of soil. The instrument has an external pH electrode with cable and it is waterproof (IP 67). The soil environmental meter can be recalibrated by using the calibration solutions that are supplied with the device.


  • Measuring range: 0.00 … 14.00 pH
  • Resolution: 0.01 pH
  • waterproof (IP 67)
  • Data-Hold function
  • Calibration: automatic, pH 4, 7, or 10
  • pH electrode for piercing into Soil
  • Incl. ISO calibration certificate

  • *Care must be taken when inserting probe to not break it**
Climate Meter PCE-HT 70-ICA incl. ISO Calibration Certificate
US$ 297.00
ex. VAT, ex. delivery costs
ISO Calibration

The climate meter records the air temperature and humidity and stores them internally. The compact climate meter with a large memory (up to a maximum of 16,000 values) is primarily used for long-term registration, for example in the food sector (e.g. refrigerated counters in supermarkets, refrigerated transport, warehouses) or in the industrial sector (heating and cooling processes, machine temperatures, product warehouses…)

  • Measuring range temperature: -40 … 85 °C / -40 … 185 °F
  • Measuring range rel. humidity: 0 … 100%
  • Max. 16,000 data records can be saved
  • Export to software possible
  • 450 day running time
  • Adjustable storage rate from 1 second
  • incl. ISO Calibration Certificate

Environmental Meter PCE-HT 70-ICA incl. ISO Calibration Certificate
US$ 297.00
ex. VAT, ex. delivery costs
ISO Calibration

The environmental meter records the air temperature and humidity and stores them internally. The compact environmental meter with a large memory (up to a maximum of 16,000 values) is primarily used for long-term registration, for example in the food sector (e.g. refrigerated counters in supermarkets, refrigerated transport, warehouses) or in the industrial sector (heating and cooling processes, machine temperatures, product warehouses…)

  • Measuring range temperature: -40 … 85 °C / -40 … 185 °F
  • Measuring range rel. humidity: 0 … 100%
  • Max. 16,000 data records can be saved
  • Export to software possible
  • 450 day running time
  • Adjustable storage rate from 1 second
  • incl. ISO Calibration Certificate

Temperature Meter PCE-HT 70-ICA incl. ISO Calibration Certificate
US$ 297.00
ex. VAT, ex. delivery costs
ISO Calibration

The temperature meter records the air temperature and humidity and stores them internally. The compact temperature meter with a large memory (up to a maximum of 16,000 values) is primarily used for long-term registration, for example in the food sector (e.g. refrigerated counters in supermarkets, refrigerated transport, warehouses) or in the industrial sector (heating and cooling processes, machine temperatures, product warehouses…)

  • Measuring range temperature: -40 … 85 °C / -40 … 185 °F
  • Measuring range rel. humidity: 0 … 100%
  • Max. 16,000 data records can be saved
  • Export to software possible
  • 450 day running time
  • Adjustable storage rate from 1 second
  • incl. ISO Calibration Certificate

Moisture Meter PCE-HT 70-ICA incl. ISO Calibration Certificate
US$ 297.00
ex. VAT, ex. delivery costs
ISO Calibration

The moisture meter records the air temperature and humidity and stores them internally. The compact moisture meter with a large memory (up to a maximum of 16,000 values) is primarily used for long-term registration, for example in the food sector (e.g. refrigerated counters in supermarkets, refrigerated transport, warehouses) or in the industrial sector (heating and cooling processes, machine temperatures, product warehouses…)

  • Measuring range temperature: -40 … 85 °C / -40 … 185 °F
  • Measuring range rel. humidity: 0 … 100%
  • Max. 16,000 data records can be saved
  • Export to software possible
  • 450 day running time
  • Adjustable storage rate from 1 second
  • incl. ISO Calibration Certificate

Environmental Meter PCE-IR 100-ICA Incl. ISO Calibration Certificate
US$ 296.00
ex. VAT, ex. delivery costs
ISO Calibration

The PCE-IR 100 is an environmental meter for measuring surface temperature and the core temperature of food. This environmental meter allows for quick and easy testing of food surface temperatures without contamination using the infrared sensor, while also offering the possibility of testing food internal temperatures using the food-quality sensor probe.


  • Infrared temperature range: -33 … +250ºC / -27 … 428ºF
  • Probe temperature range: -55 … 330ºC / -67 … 626ºF
  • Resolution: 0.2ºC / 0.36ºF
  • IP 65 ingress protection rating allows hygienic cleaning

Mini Clamp Meter PCE-DC1-ICA Incl. ISO Calibration Certificate
US$ 274.00
ex. VAT, ex. delivery costs
ISO Calibration
This Mini Clamp Meter was developed for the indirect acquisition of AC / DC currents as well as the frequency. A non-contact voltage tester function and a flashlight for illuminating the measuring point were also integrated in this Mini Clamp Meter.

  • AC / DC current, AC voltage and frequency measurement
  • Integrated measuring point illumination
  • Non-contact voltage tester
  • Automatic range selection
  • Forceps opening: 18 mm
  • Automatic switch-off
  • Incl. ISO calibration certificate
Environmental Meter PCE-IR 90-ICA incl. ISO-Calibration Certificate
US$ 285.00
ex. VAT, ex. delivery costs
ISO Calibration
The environmental meter is used to check the temperature of food. In addition to the surface temperature via the infrared sensor, the environmental meter can also be used to determine the core temperature via the fold-out resistance temperature sensor.

  • Infrared measuring range: -40 … 300°C / -40 … 572°F
  • Sensor measuring range: -40 … 300°C / -40 … 572°F
  • Charging station with micro USB cable
  • Bluetooth interface
  • incl. ISO-Calibration Certificate
Condition Monitoring Tachometer PCE-T 238
US$ 298.00
ex. VAT, ex. delivery costs
The condition monitoring tachometer is a battery-powered hand-held device that allows mobile use. The condition monitoring tachometer can perform a contact measurement as well as a non-contact measurement. It is also possible to perform a measurement of the surface velocity. The condition monitoring tachometer allows a measurement of up to 99,999 revolutions per minute. This measuring range is possible with contactless measurements with the optical tachometer.

  • Continuous data output
  • Contactless measurement range: 5 … 99,999 RPM
  • Contact measurement range: 0.5 … 19,999 RPM
  • Surface measurement range: 0.05 … 1,999.9 m/min
  • Measuring distance without contact: 5 … 150 cm / 1.9" … 4.9 ft