Data Logger with USB Interface PCE-430
US$ 2,846.00
ex. VAT, ex. delivery costs

The class 1 data logger with USB interface meets all requirements for noise measurement and frequency analysis. This integrating precision pulse sound level data logger with USB interface complies with all applicable standards and guidelines.

  • Accuracy class 1
  • A, B, C & Z frequency weighting
  • Fast, Slow, Impulse and Peak time weighting
  • Statistics function
  • 1/1 octave band included
  • 1/3 octave band optional

Ultrasonic Flow Meter PCE-TDS 75
US$ 2,688.00
ex. VAT, ex. delivery costs
The ultrasonic flow meter is a fixed installation meter. The flow rate of liquids in pipes can be determined with this flow meter. The sensors from the ultrasonic flow meter can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.

  • Measuring range:± 0.03 … ± 5 m / s
  • Measuring accuracy: ± 1%  (of the measured value)
  • Pipe size: DN 25 … 1200 mm
  • Interface: RS232 & RS485
  • Relay output
HVAC Meter PCE-TDS 75
US$ 2,688.00
ex. VAT, ex. delivery costs
The ultrasonic HVAC meter is a fixed installation meter. The flow rate of liquids in pipes can be determined with this HVAC meter. The sensors from the ultrasonic HVAC meter can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.

  • Measuring range: ± 0.03 … ± 5 m / s
  • Measuring accuracy: ± 1% of the measured value
  • Pipe diameter: 25 … 1200 mm (1 … 48 in)
  • Interface: RS232 & RS485
  • Relay output
Portable Ultrasonic Flow Meter PCE-TDS 75
US$ 2,688.00
ex. VAT, ex. delivery costs
The Portable Ultrasonic Flow Meter is a fixed installation meter. The flow rate of liquids in pipes can be determined with this flow meter. The sensors from the Portable Ultrasonic Flow Meter can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.

  • Measuring range: ± 0.03 … ± 5 m / s
  • Measuring accuracy: ± 1% of the measured value
  • Pipe diameter: 25 … 1200 mm (1 … 48 in)
  • Interface: RS232 & RS485
  • Relay output
Ultrasonic Flow Meter PCE-TDS 75
US$ 2,688.00
ex. VAT, ex. delivery costs
The ultrasonic flow meter is a fixed installation meter. The flow rate of liquids in pipes can be determined with this flow meter. The sensors from the ultrasonic flow meter can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.

  • Measuring range: ± 0.03 … ± 5 m / s
  • Measuring accuracy: ± 1% of the measured value
  • Pipe diameter: 25 … 1200 mm (1 … 48 in)
  • Interface: RS232 & RS485
  • Relay output
Ultrasonic Flow Tester PCE-TDS 75
US$ 2,688.00
ex. VAT, ex. delivery costs
The ultrasonic flow tester is a fixed installation meter. The flow rate of liquids in pipes can be determined with this ultrasonic flow tester. The sensors from the ultrasonic flow tester can be mounted directly on the pipes to be measured without having to cut them open. The flow velocity is calculated using the transit-time principle which requires the solid impurities be less than 5% for accuracy.

  • Measuring range: ± 0.03 … ± 5 m / s
  • Measuring accuracy: ± 1% of the measured value
  • Pipe diameter: 25 … 1200 mm (1 … 48 in)
  • Interface: RS232 & RS485
  • Relay output
Ultrasonic testing device PCE-TDS 75
US$ 2,688.00
ex. VAT, ex. delivery costs
The Ultrasonic testing device is a fixed installation meter. The flow rate of liquids in pipes can be determined with this Ultrasonic testing device. The sensors from the Ultrasonic testing device can be mounted directly on the pipes to be measured without having to cut them open.

  • Measuring range: ± 0.03 … ± 5 m / s
  • Measuring accuracy: ± 1% of the measured value
  • Pipe diameter: 25 … 1200 mm (1 … 48 in)
  • Interface: RS232 & RS485
  • Relay output
Electrical Tester PCE-IT 150
US$ 2,450.00
ex. VAT, ex. delivery costs
The electrical tester is for insulation measurements with a test voltage of up to 15 kV. The measuring range of 0 … 30 TΩ and other measuring functions make the tester versatile. With 4 quick selection buttons for common test voltages and the option of setting the voltage in 500 V steps. Pre-configured diagnostic tests, including (PI), dielectric absorption ratio (DAR) and a memory function for 200 measurements are integrated into the electrical tester.

  • Insulation resistance: 0 … 30 TΩ
  • Accuracy: ± (5% of Mw.+5 digits)
  • Test voltage: 500 V … 15 kV
  • Direct alternating voltage: 30 … 600 V
  • Accuracy: ± (2.0% v.Mw. +3 digits)
  • Polarisation index PI
  • Dielectric absorption ratio DAR
  • Memory and software
Pyrometer PCE-TC 38
US$ 2,583.00
ex. VAT, ex. delivery costs
Our Pyrometer offers reliable temperature measurement within a range from -20 °C to 550 °C (-4 °F to 1022 °F). The infrared images are displayed with a resolution of 384 x 288 pixels on the 3.5 inch colour display. The Pyrometer saves more than 40,000 images in the internal 6 GB memory in JPG format.

  • measurement range: -20 ... 550 °C
  • infrared image resolution: 384 x 288 pixels
  • frame rate: 25 Hz
  • wavelength range: 8 ... 14 µm
  • emissivity: 0.01 ... 1