Zum Hauptinhalt springen
Condition Monitoring Stroboscope PCE-LES 400-ICA incl. ISO-Calibration Certificate
US$ 1,914.00
ex. VAT, ex. delivery costs
ISO Calibration
A Condition Monitoring Stroboscope is a device for permanent installation that generates rapid flashes of light with energy-efficient and long-lasting LEDs. With a wide measurement range of 50 ... 36,000 FPM, a high resolution of 0.1 FPM and an accuracy of 0.01 %, it offers precise and reliable measurements. Our Condition Monitoring Stroboscope can be triggered both internally and externally and supports four external trigger modes.

  • frequency: 50 ... 36000 FPM
  • resolution: 0.1 FPM
  • accuracy: ±0.01 % of Rd.
  • frequency: 1 ... 600 Hz
  • resolution: 0.01 Hz
  • accuracy: ±0.01 % of Rd.
  • flash duration 1 ... 3 %, max. 100 µs
  • trigger input
  • incl. ISO-Calibration Certificate
Rotation Meter PCE-LES 400-ICA incl. ISO-Calibration Certificate
US$ 1,914.00
ex. VAT, ex. delivery costs
ISO Calibration
A Rotation Meter is a device for permanent installation that generates rapid flashes of light with energy-efficient and long-lasting LEDs. With a wide measurement range of 50 ... 36,000 FPM, a high resolution of 0.1 FPM and an accuracy of 0.01 %, it offers precise and reliable measurements. Our Rotation Meter can be triggered both internally and externally and supports four external trigger modes.

  • frequency: 50 ... 36000 FPM
  • resolution: 0.1 FPM
  • accuracy: ±0.01 % of Rd.
  • frequency: 1 ... 600 Hz
  • resolution: 0.01 Hz
  • accuracy: ±0.01 % of Rd.
  • flash duration 1 ... 3 %, max. 100 µs
  • trigger input
  • incl. ISO-Calibration Certificate
Stroboscope / Stroboscope Light PCE-LES 400-ICA incl. ISO-Calibration Certificate
US$ 1,914.00
ex. VAT, ex. delivery costs
ISO Calibration
A Stroboscope / Stroboscope Light is a device for permanent installation that generates rapid flashes of light with energy-efficient and long-lasting LEDs. With a wide measurement range of 50 ... 36,000 FPM, a high resolution of 0.1 FPM and an accuracy of 0.01 %, it offers precise and reliable measurements. Our Stroboscope / Stroboscope Light can be triggered both internally and externally and supports four external trigger modes.

  • frequency: 50 ... 36000 FPM
  • resolution: 0.1 FPM
  • accuracy: ±0.01 % of Rd.
  • frequency: 1 ... 600 Hz
  • resolution: 0.01 Hz
  • accuracy: ±0.01 % of Rd.
  • flash duration 1 ... 3 %, max. 100 µs
  • trigger input
  • incl. ISO-Calibration Certificate
Tachometer PCE-LES 400-ICA incl. ISO-Calibration Certificate
US$ 1,914.00
ex. VAT, ex. delivery costs
ISO Calibration
A Tachometer is a device for permanent installation that generates rapid flashes of light with energy-efficient and long-lasting LEDs. With a wide measurement range of 50 ... 36,000 FPM, a high resolution of 0.1 FPM and an accuracy of 0.01 %, it offers precise and reliable measurements. Our Tachometer can be triggered both internally and externally and supports four external trigger modes.

  • frequency: 50 ... 36000 FPM
  • resolution: 0.1 FPM
  • accuracy: ±0.01 % of Rd.
  • frequency: 1 ... 600 Hz
  • resolution: 0.01 Hz
  • accuracy: ±0.01 % of Rd.
  • flash duration 1 ... 3 %, max. 100 µs
  • trigger input
  • incl. ISO-Calibration Certificate
Vibration Analyzer / Vibration Analyser PCE-LES 400-ICA incl. ISO-Calibration Certificate
US$ 1,914.00
ex. VAT, ex. delivery costs
ISO Calibration
A Vibration Analyzer / Vibration Analyser is a device for permanent installation that generates rapid flashes of light with energy-efficient and long-lasting LEDs. With a wide measurement range of 50 ... 36,000 FPM, a high resolution of 0.1 FPM and an accuracy of 0.01 %, it offers precise and reliable measurements. Our Vibration Analyzer / Vibration Analyser can be triggered both internally and externally and supports four external trigger modes.

  • frequency: 50 ... 36000 FPM
  • resolution: 0.1 FPM
  • accuracy: ±0.01 % of Rd.
  • frequency: 1 ... 600 Hz
  • resolution: 0.01 Hz
  • accuracy: ±0.01 % of Rd.
  • flash duration 1 ... 3 %, max. 100 µs
  • trigger input
  • incl. ISO-Calibration Certificate
Vibration Meter / Vibration Tester PCE-LES 400-ICA incl. ISO-Calibration Certificate
US$ 1,914.00
ex. VAT, ex. delivery costs
ISO Calibration
A Vibration Meter / Vibration Tester is a device for permanent installation that generates rapid flashes of light with energy-efficient and long-lasting LEDs. With a wide measurement range of 50 ... 36,000 FPM, a high resolution of 0.1 FPM and an accuracy of 0.01 %, it offers precise and reliable measurements. Our Vibration Meter / Vibration Tester can be triggered both internally and externally and supports four external trigger modes.

  • frequency: 50 ... 36000 FPM
  • resolution: 0.1 FPM
  • accuracy: ±0.01 % of Rd.
  • frequency: 1 ... 600 Hz
  • resolution: 0.01 Hz
  • accuracy: ±0.01 % of Rd.
  • flash duration 1 ... 3 %, max. 100 µs
  • trigger input
  • incl. ISO-Calibration Certificate
Automotive Tester LM-MCDX-52D
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Automotive Tester. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for the Automotive Tester allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: FE: 2 ... 5000 µm
  • Coating thickness: NF: 2 ... 2000 µm
  • Resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Dual probe with sliding sleeve and prism
Automotive Tester LM-MCDX-7F
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Automotive Tester. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method of this Automotive Tester allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 7000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • FE probe for thick layers with sliding sleeve and prism
Car Measuring Device LM-MCDX-52D
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Car Measuring Device. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for the Car Measuring Device allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: FE: 2 ... 5000 µm
  • Coating thickness: NF: 2 ... 2000 µm
  • Resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Dual probe with sliding sleeve and prism
Car Measuring Device LM-MCDX-7F
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Car Measuring Device. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method of this Car Measuring Device allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 7000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • FE probe for thick layers with sliding sleeve and prism
Coating Thickness Gauge LM-MCDX-52D
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Coating Thickness Gauge. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for the Coating Thickness Gauge allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: FE: 2 ... 5000 µm
  • Coating thickness: NF: 2 ... 2000 µm
  • Resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Dual probe with sliding sleeve and prism
Coating Thickness Gauge LM-MCDX-7F
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Coating Thickness Gauge. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method of this Coating Thickness Gauge allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 7000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • FE probe for thick layers with sliding sleeve and prism
Dynamometer PCE-DFG 20K X
US$ 1,905.00
ex. VAT, ex. delivery costs
The dynamometer records both tensile and compressive forces with extremely precise accuracy. Tensile and compressive forces are frequently measured in test laboratories, for example to determine yield points, tear-off force or the force required to actuate buttons or switches. The dynamometer is supplied with an external measuring cell and can measure forces of up to 20 kN.

  • Measuring range: 0 … 20 kN
  • Resolution: 2 N
  • Accuracy: ±0.05 % F.S.
  • 32 GB memory for 30 million measuring points
  • USB-C interface
  • Graphic display
  • Measuring rate: 1 … 7200 Hz
Dynamometer PCE-DFG 50K X
US$ 1,905.00
ex. VAT, ex. delivery costs
The dynamometer records both tensile and compressive forces with extremely precise accuracy. Tensile and compressive forces are frequently measured in test laboratories, for example to determine yield points, tear-off force or the force required to actuate buttons or switches. The device is supplied with an external measuring cell and can measure forces of up to 50 kN.

  • Measuring range: 0 … 50 kN
  • Resolution: 5 N
  • Accuracy: ±0.05 % F.S.
  • 32 GB memory for 30 million measuring points
  • USB-C interface
  • Graphic display
  • Measuring rate: 1 … 7200 Hz
Force Gauge PCE-DFG 20 X
US$ 1,905.00
ex. VAT, ex. delivery costs
The force measuring device records both tensile and compressive forces with extremely precise accuracy. Tensile and compressive forces are frequently measured in test laboratories, for example to determine yield points, tear-off force or the force required to actuate buttons or switches. The force gauge is supplied with an external measuring cell and can measure forces of up to 20 kN.

  • Measuring range: 0 … 20 kN
  • Resolution: 2 N
  • Accuracy: ±0.05 % F.S.
  • 32 GB memory for 30 million measuring points
  • USB-C interface
  • Graphic display
  • Measuring rate: 1 … 7200 Hz
Force Gauge PCE-DFG 50K X
US$ 1,905.00
ex. VAT, ex. delivery costs
The force measuring device records both tensile and compressive forces with extremely precise accuracy. Tensile and compressive forces are frequently measured in test laboratories, for example to determine yield points, tear-off force or the force required to actuate buttons or switches. The force gauge is supplied with an external measuring cell and can measure forces of up to 50 kN.

  • Measuring range: 0 … 50 kN
  • Resolution: 5 N
  • Accuracy: ±0.05 % F.S.
  • 32 GB memory for 30 million measuring points
  • USB-C interface
  • Graphic display
  • Measuring rate: 1 … 7200 Hz
Material Tester LM-MCDX-52D
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Material Tester. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for the Material Tester allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: FE: 2 ... 5000 µm
  • Coating thickness: NF: 2 ... 2000 µm
  • Resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Dual probe with sliding sleeve and prism
Material Tester LM-MCDX-7F
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Material Tester. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method of this Material Tester allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 7000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • FE probe for thick layers with sliding sleeve and prism
Material Thickness Meter LM-MCDX-52D
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Material Thickness Meter. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for the Material Thickness Meter allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: FE: 2 ... 5000 µm
  • Coating thickness: NF: 2 ... 2000 µm
  • Resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Dual probe with sliding sleeve and prism
Material Thickness Meter LM-MCDX-7F
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Material Thickness Meter. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method of this Material Thickness Meter allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 7000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • FE probe for thick layers with sliding sleeve and prism
Paint Gauge / Paint Tester LM-MCDX-52D
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Paint Gauge / Paint Tester. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for the Paint Gauge / Paint Tester allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: FE: 2 ... 5000 µm
  • Coating thickness: NF: 2 ... 2000 µm
  • Resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Dual probe with sliding sleeve and prism
Paint Gauge / Paint Tester LM-MCDX-7F
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Paint Gauge / Paint Tester. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method of this Paint Gauge / Paint Tester allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 7000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • FE probe for thick layers with sliding sleeve and prism
Paint Test Equipment / Paint Testing Equipment LM-MCDX-52D
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Paint Test Equipment / Paint Testing Equipment. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for the Paint Test Equipment / Paint Testing Equipment allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: FE: 2 ... 5000 µm
  • Coating thickness: NF: 2 ... 2000 µm
  • Resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Dual probe with sliding sleeve and prism
Paint Test Equipment / Paint Testing Equipment LM-MCDX-7F
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Paint Test Equipment / Paint Testing Equipment. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method of this Paint Test Equipment / Paint Testing Equipment allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 7000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • FE probe for thick layers with sliding sleeve and prism
Surface Testing LM-MCDX-52D
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Surface Testing. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for the Surface Testing allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: FE: 2 ... 5000 µm
  • Coating thickness: NF: 2 ... 2000 µm
  • Resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Dual probe with sliding sleeve and prism
Surface Testing LM-MCDX-7F
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Surface Testing. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method of this Surface Testing allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 7000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • FE probe for thick layers with sliding sleeve and prism
Thickness Gauge LM-MCDX-52D
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Thickness Gauge. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for the Thickness Gauge allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: FE: 2 ... 5000 µm
  • Coating thickness: NF: 2 ... 2000 µm
  • Resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Dual probe with sliding sleeve and prism
Thickness Gauge LM-MCDX-7F
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Thickness Gauge. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method of this Thickness Gauge allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 7000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • FE probe for thick layers with sliding sleeve and prism
Thickness Meter LM-MCDX-52D
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Thickness Meter. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for the Thickness Meter allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: FE: 2 ... 5000 µm
  • Coating thickness: NF: 2 ... 2000 µm
  • Resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Dual probe with sliding sleeve and prism
Thickness Meter LM-MCDX-7F
US$ 1,905.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Thickness Meter. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method of this Thickness Meter allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 7000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • FE probe for thick layers with sliding sleeve and prism
Belt Tension Meter PCE-BTM 2000TVT-KIT Maintenance Kit
US$ 1,881.00
ex. VAT, ex. delivery costs

A belt tension meter measures the belt tension of a belt when it is stationary. The maintenance kit includes a vibration accelerometer for checking vibrating parts, machines and systems. It is also possible to measure the surface speed with a tachometer up to 99,999 revolutions per minute.

Belt Tension Meter

  • Measurement of the vibration frequency of the belt
  • Measuring range: 10 … 900 Hz
  • Accuracy: ± (1% of reading + 4 digits)Vibration Meter
  • Acceleration: 0.0 … 399.9 m/s² / 0.0 - 15744 in/s²
  • Velocity: 0.00 … 399.9 mm/s / 0.00 - 15.74 in/s
  • Displacement: 0.000 … 3.9 mm / 0.000 - 0.154 inTachometer
  • Contactless measurement: 5 … 99,999 rpm
  • Contact measurement: 0.5 … 19,999 rpm
  • Surface measurement: 0.05 … 1,999.9 m/min

Accelerometer PCE-VT 3850S
US$ 1,875.00
ex. VAT, ex. delivery costs
The accelerometer is the ideal companion for checking vibrating parts, machines and systems. With the external vibration sensor on the accelerometer, the vibration displacement up to 3.9 mm, the vibration velocity up to 399.9 mm/s and the vibration acceleration up to 399.9 m/s² can be determined.

Measuring ranges
  • Acceleration: 0.0 … 399.9 m/s² / 0.0 - 15744 in/s²
  • Velocity: 0.00 … 399.9 mm/s / 0.00 - 15.74 in/s
  • Displacement: 0.000 … 3.9 mm / 0.000 - 0.154 in
  • Automatic ISO 10816-3 evaluation
  • Data logger: 50 memory locations with 43200 measured values each
  • Rechargeable battery
  • Color graphic display
  • Measuring tip with handgrip- incl. headset
Aerosol meter / Aerosol measuring device PCE-PCO 2
US$ 1,875.00
ex. VAT, ex. delivery costs

PCE-PCO 2 is a portable handheld Aerosol meter / Aerosol measuring device or particle counter used to monitor particulate matter (PM) concentrations in the air. Designed to aid in indoor air quality (IAQ) assessments, this particle counter also measures air temperature, dew point and relative humidity.


  • PM channels:PM 2.5, PM 10, including mass concentration mode (µg/m³)
  • Particle sizes (in micrometers): 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10 µm
  • Temp. measuring range: 0 … +50 °C / +32 … +122 °F
  • Humidity measuring range: 0 … 100 % RH
  • Built-in camera for image and video recording
  • Free software download on PCE Software web page

 

Aerosol particle counter PCE-PCO 2
US$ 1,875.00
ex. VAT, ex. delivery costs

PCE-PCO 2 is a portable handheld Aerosol particle counter or particle counter used to monitor particulate matter (PM) concentrations in the air. Designed to aid in indoor air quality (IAQ) assessments, this particle counter also measures air temperature, dew point and relative humidity.


  • PM channels:PM 2.5, PM 10, including mass concentration mode (µg/m³)
  • Particle sizes (in micrometers): 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10 µm
  • Temp. measuring range: 0 … +50 °C / +32 … +122 °F
  • Humidity measuring range: 0 … 100 % RH
  • Built-in camera for image and video recording
  • Free software download on PCE Software web page

 

Agricultural measuring device PCE-TUM 50
US$ 1,875.00
ex. VAT, ex. delivery costs
The Agricultural measuring device PCE-TUM 50 is a portable device for measuring turbidity according to ISO 7027. This allows the user to quickly and easily determine important water parameters with the Agricultural measuring device and to check the quality of drinking water and waste water.

  • Measurement method: ISO 7027 (90°)
  • Measuring ranges:
    0 … 2000 NTU
    0 … 500 EBC
    0 … 9999 ASBC
  • 3 measuring unitsTurbidity calibration up to 7 points
Air Flow Meter PCE-WSAC 50W 230
US$ 1,875.00
ex. VAT, ex. delivery costs
The Air Flow Meter PCE-WSAC 50W 230 is primarily used to measure and monitor the wind load on cranes or wind turbines. Furthermore, the wind situation can be measured and analyzed before commissioning a wind turbine. The high measuring range of up to 50 m/s of the air flow meter means stormy gusts can also be monitored.

  • Measuring range up to 180 km / h
  • Input: Pulse, analogue (4 … 20-mA) or radio transmission
  • 4 … 20-mA analogue output
  • Supply voltage: 110 … 230V AC, 50/60 Hz
  • Ambient temperature -20 .. . 70°C / -4 … 158°F
  • Units adjustable: km / h, mph, m / s