Surface Testing LM-MCDX-5FP
US$ 1,624.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Surface Testing. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for the Surface Testing allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 5000 µm
  • Resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Standard FE probe with sliding sleeve and prism, swiveling
Surface Testing - Infrared Imaging Camera PCE-TC 32N-ICA incl. ISO Calibration Certificate
US$ 1,620.00
ex. VAT, ex. delivery costs
ISO Calibration
The infrared camera has a measuring range of -20 … +550 °C. This means that the infrared camera already covers a wide temperature range of measuring tasks. With an image frequency of 25 Hz, problems can be quickly localised with the infrared camera.

  • Measuring range: -20 … +550 °C
  • Picture-in-picture function 
  • Frame rate: 25 Hz
  • Internal/external memory
  • Wi-Fi 802.11
  • Display resolution: 240 x 320 pixels
  • Battery
    - incl. ISO Calibration Certificate
Surface Testing LM-MCDX-5F
US$ 1,545.00
ex. VAT, ex. delivery costs
Numerous specialized digital probes can be connected to the Surface Testing. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method using the Surface Testing allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 5000 µm
  • Resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 px)
  • Data storage
  • USB and wireless
  • Standard FE probe with sliding sleeve and prism
Surface Tester - Hardness PCE-2550-ICA incl. ISO Calibration Certificate
US$ 1,505.00
ex. VAT, ex. delivery costs
ISO Calibration

Due to its compact design, the PCE-2550-ICA Surface Tester - Hardness is easy to use for incoming and outgoing inspections. Due to the adjustable hardness scales, the hardness tester is very versatile.

  • Measuring ranges: 170 … 960 HLD
  • Measurement direction: 360°
  • Impact device: Type D
  • Measurement units: HL, HB, HRB, HRC, HRA, HV, HS
  • Internal measurement memory
  • incl. ISO Calibration Certificate

Surface Testing - Automotive Tester / Borescope PCE-VE 340N
US$ 1,496.00
ex. VAT, ex. delivery costs

PCE-VE 340N is an automotive tester, borescope, inspection camera or industrial endoscope for the non-destructive inspection (NDI) of engines, machines and more. This industrial borescope is an ideal tool for diagnosing issues in hard-to-reach places. The waterproof camera head features 4 LED lights with automatic illumination. In addition, digital image magnification or zoom of up to 2 times is available.


  • Diameter camera head: Ø 5.5mm / 0.22"
  • Interface: Mini-USB 1.1 and AV out
  • Memory: 8 GB SD memory card (incl.)
  • Cable length: 10 m / 32 ft 9"

Surface Tester PCE-CT 80-F5N3-ICA incl. ISO-Calibration Certificate
US$ 1,373.00
ex. VAT, ex. delivery costs
ISO Calibration
The surface tester is a measuring device for non-destructive measurement of coatings (varnishes, paints, plastics …) on steel / iron and non-ferrous metals. Thanks to the externally connected sensor on the surface tester, measuring points that are difficult to access can also be easily reached.


  • Measuring range: Fe: 0 … 5000 µm, NFe: 0 … 3000 µm
  • Accuracy after foil calibration: ±(2% of reading + 1 µm)
  • For many materials such as: iron, steel, aluminum, copper, brass, stainless steel
  • Diameter: 17mm / 0.67"
  • incl. ISO-Calibration Certificate

Surface Testing PCE-900-ICA incl. ISO Calibration Certificate
US$ 1,371.00
ex. VAT, ex. delivery costs
ISO Calibration

The Leeb Surface Testing PCE-900-ICA measures the hardness of nine different metals using the Leeb rebound method. This means that with the Surface Testing a firing pin bounces on a metallic surface and the intensity of the rebound is used as an indicator of the material hardness. The Surface Testing measures the metal hardness in 6 different hardness scales. 

  • Measurement according to Leeb Rebound method
  • Testing of HRC, HRB, HV, HB, HSD
  • Measurement Range: 200-900 HLD / 13-99 HRB / 20-68 HRC / 20-655 HB / 80-940 HV / 32-99 HSD
  • Accuracy: 0.80% / Repeatability: 1.10%
  • Incl. type D Leeb probe
  • Optional Software Available
  • incl. ISO Calibration Certificate

Surface Tester PCE-CT 80-FN3-ICA incl. ISO-Calibration Certificate
US$ 1,364.00
ex. VAT, ex. delivery costs
ISO Calibration
The surface tester is a measuring device for non-destructive measurement of coatings (varnishes, paints, plastics …) on steel / iron and non-ferrous metals. Thanks to the externally connected sensor on the surface tester, measuring points that are difficult to access can also be easily reached.

  • Measuring range: Fe: 0 … 3000 µm, NFe: 0 … 3000 µm
  • Accuracy after foil calibration: ±(2% of reading + 1 µm)
  • For many materials such as: iron, steel, aluminum, copper, brass, stainless steel
  • Diameter: 17mm / 0.67"
  • incl. ISO-Calibration Certificate
Surface Tester PCE-CT 80-FN2D5-ICA incl. ISO-Calibration Certificate
US$ 1,356.00
ex. VAT, ex. delivery costs
ISO Calibration
The surface tester is a measuring device for non-destructive measurement of coatings (varnishes, paints, plastics …) on steel / iron and non-ferrous metals. Thanks to the externally connected sensor on the surface tester, measuring points that are difficult to access can also be easily reached.

  • Measuring range: Fe: 0 … 2500 µm, NFe: 0 … 2500 µm
  • Accuracy after foil calibration: ±(2% of reading + 1 µm)
  • For many materials such as: iron, steel, aluminum, copper, brass, stainless steel
  • Diameter: 17mm / 0.67"
  • incl. ISO-Calibration Certificate