Handheld Digital Refractometer PCE-DRW 2 Wine
US$ 465.00
ex. VAT, ex. delivery costs

PCE-DRW 2 is a handheld digital refractometer used to determine the sugar content / alcohol content (% vol ap) / °Oechsle (°Oe) / KMN (babo) of wine and similar liquids in the 0 … 45 % Brix / 0 … 22% vol ap / 3 … 150 °Oe / 0 … 25 KMW measuring range. This waterproof IP65-rated digital refractometer features automatic temperature compensation (ATC) from +10 … +40 °C / +50 … +104 °F, as well as a large, easy-to-read LCD that shows both the measured value and the temperature.

Measurement parameters:

  • Brix, % vol ap, °Oechsle, KMW, temperature
  • Measurement range: 0 … 45 % Brix 
  • Resolution: 0.1 % Brix
  • Accuracy: ±0.2 % Brix 
  • Automatic temperature compensation (ATC)

Handheld Digital Refractometer PCE-DRW 1 Beer
US$ 404.00
ex. VAT, ex. delivery costs

PCE-DRW 1 is a handheld digital refractometer used to determine the sugar content / specific gravity of beer and similar liquids in the 0 … 50 % Brix / 1.000 … 1.130 d 20⁄20 measuring range. This waterproof IP65-rated digital refractometer features automatic temperature compensation (ATC) from +10 … +40 °C / +50 … +104 °F, as well as a large, easy-to-read LCD that shows both the measured value and the temperature.

Measurement parameters:

  • Brix, specific gravity (d 20⁄20), temperature
  • Measurement range: 0 … 50 % 
  • Resolution: 0.1 % Brix 
  • Accuracy: ±0.2 % Brix
  • Automatic temperature compensation (ATC)

Power Analyzer PCE-830-2
US$ 3,564.00
ex. VAT, ex. delivery costs

The PCE-830-2 Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Analyzer also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-6802 amp clamp (1000 A)
  • Electrical conductor pick-up: 55 mm / 2.1 in diameter
  • Range selection: manual (10 A, 100 A, 1000 A)
  • Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values (single phase)

Power Meter PCE-830-2
US$ 3,564.00
ex. VAT, ex. delivery costs

The PCE-830-2 Power Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-6802 amp clamp (1000 A)
  • Electrical conductor pick-up: 55 mm / 2.1 in diameter
  • Range selection: manual (10 A, 100 A, 1000 A)
  • Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values (single phase)

Clamp Meter PCE-830-2
US$ 3,564.00
ex. VAT, ex. delivery costs

The PCE-830-2 Clamp Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-6802 amp clamp (1000 A)
  • Electrical conductor pick-up: 55 mm / 2.1 in diameter
  • Range selection: manual (10 A, 100 A, 1000 A)
  • Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values (single phase)

Clamp on Tester PCE-830-2
US$ 3,564.00
ex. VAT, ex. delivery costs

The PCE-830-2 Clamp on Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp on Tester also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-6802 amp clamp (1000 A)
  • Electrical conductor pick-up: 55 mm / 2.1 in diameter
  • Range selection: manual (10 A, 100 A, 1000 A)
  • Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values (single phase)

Data Logger PCE-830-2
US$ 3,564.00
ex. VAT, ex. delivery costs

The PCE-830-2 Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logger also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-6802 amp clamp (1000 A)
  • Electrical conductor pick-up: 55 mm / 2.1 in diameter
  • Range selection: manual (10 A, 100 A, 1000 A)
  • Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values (single phase)

HVAC Meter PCE-830-2
US$ 3,564.00
ex. VAT, ex. delivery costs

The PCE-830-2 HVAC Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This HVAC Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-6802 amp clamp (1000 A)
  • Electrical conductor pick-up: 55 mm / 2.1 in diameter
  • Range selection: manual (10 A, 100 A, 1000 A)
  • Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values (single phase)

Clamp Meter PCE-PA 8300-2
US$ 4,105.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Clamp Meter is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


  • Voltage measurement range of 10 V … 600 V AC
  • Current measurement range of (Set 2) 30 A … 3000 A AC
  • Performance measurement range of 0 kW … 9.999 MW (VA/VAR)
  • Simultaneous display of harmonics and waveform
  • Graphic Phasor diagram
  • Captures transients including dip, swell, and outage