£ 731.00
| Frequency range | 50 MHz ... 3.5 GHz |
| Sensor type | electric field (E) |
| Measurement | 3-dimensional, isotropic |
| Measuring ranges |
20 mV/m ... 108.0 V/m |
| Measuring range selection | automatic |
| Response time | 1 s (until 90% of the final value is reached) |
| Display units | mV/m , V/m , µA/m , mA/m, µW/m² , mW/m² |
| Resolution | 0.1mV/m 0.1 µgA/m 0.01 µgW/m² |
| Measurement error (absolute) (at 1 V/m and 50 MHz) | ±1.0 dB |
| Accuracy (frequency dependent) | ±1.0 dB (50 MHz ... 1.9 GHz) ±2.4 dB (1.9 GHz ... 3.5 GHz) |
| Isotropic deviation | ±1.0 dB (at frequency >50 MHz ) |
| Maximum overrange | 4.2 W/m² (40 V/m) |
| Temperature-related deviation | ±1.5 dB |
| Display | 4-digit LCD |
| Refresh of the display values | every 400 ms |
| Limit | adjustable |
| Alarm | beep when limit is exceeded |
| Calibration factor | adjustable |
| Averaging | adjustable over 4 s ... 15 min |
| Internal measurement memory | 99 records |
| Measured values that can be displayed | current measured value, maximum value, mean value |
| Supply | 9 V block battery |
| Weight | 350 g / 0.78 lb (including battery) |