The Digital Multimeter is used to test electrical components, cables and circuits. During maintenance and repair work, the Digital Multimeter helps to isolate faults and check electrical connections. It measures DC and AC voltage, resistance, capacitance and frequency. In automatic mode, the Digital Multimeter independently detects voltage, resistance and continuity and selects the appropriate measuring range. The 3.4-inch LCD display shows the measured values clearly. The equipment also includes a True RMS function for AC voltage measurements.
For fault finding, the Digital Multimeter offers a diode test and an audible continuity test. The non-contact voltage detection NCV signals detected AC voltage optically and acoustically in three levels. Using the LIVE function, a live conductor can be detected with the red test lead. With Data Hold, you can hold the displayed measured value. The integrated torch illuminates dark measuring points. In addition, the device supports frequency measurements up to 6 MHz and temperature measurements from −20 ... 1000°C via a Type K thermocouple.
The Digital Multimeter runs on two AAA batteries and shows a low battery level. After 14 minutes without operation, the Digital Multimeter emits a beep and automatically switches to sleep mode to conserve the batteries.
| DC voltage | |
| Measuring range | 0 ... 6 V |
| Resolution | 0,001 V |
| Accuracy | ±(0.8 % of Rd +3 digits) |
| DC voltage | |
| Measuring range | 0 ... 60 V |
| Resolution | 0,01 V |
| Accuracy | ±(0.8 % of Rd +3 digits) |
| DC voltage | |
| Measuring range | 0 ... 600 V |
| Resolution | 0,1 V |
| Accuracy | ±(0.8 % of Rd +3 digits) |
| DC voltage | |
| Measuring range | 0 ... 1000 V |
| Resolution | 1 V |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Capacity | |
| Measuring range | 0 ... 6 nF |
| Resolution | 0,001 nF |
| Accuracy | ±(4.5 % of Rd + 5 digits) |
| Capacity | |
| Measuring range | 0 ... 60 nF |
| Resolution | 0,01 nF |
| Accuracy | ±(4.5 % of Rd + 5 digits) |
| Capacity | |
| Measuring range | 0 ... 600 nF |
| Resolution | 0,1 nF |
| Accuracy | ±(4.5 % of Rd + 5 digits) |
| Capacity | |
| Measuring range | 0 ... 6 µF |
| Resolution | 0,001 µF |
| Accuracy | ±(4.5 % of Rd + 5 digits) |
| Capacity | |
| Measuring range | 0 ... 60 µF |
| Resolution | 0,01 µF |
| Accuracy | ±(4.5 % of Rd + 5 digits) |
| Capacity | |
| Measuring range | 0 ... 600 µF |
| Resolution | 0,1 µF |
| Accuracy | ±(4.5 % of Rd + 5 digits) |
| Capacity | |
| Measuring range | 0 ... 60 mF |
| Resolution | 0,001 mF |
| Accuracy | ±(4.5 % of Rd + 5 digits) |
| Type K temperature | |
| Measuring range | -20 ... 0 °C |
| Resolution | 1 °C |
| Accuracy | ±(5% of measured value + 4 digits) |
| Type K temperature | |
| Measuring range | 1 ... 400 °C |
| Resolution | 1 °C |
| Accuracy | ±(1% of Rd +3 digits) |
| Type K temperature | |
| Measuring range | 401 ... 1000 °C |
| Resolution | 1 °C |
| Accuracy | ±(2 % of Rd +5 digits) |
| Type K temperature | |
| Measuring range | -4 ... +32 °F |
| Resolution | 1 °F |
| Accuracy | ±(5% of measured value + 8 digits) |
| Type K temperature | |
| Measuring range | 33,8 ... 752 °F |
| Resolution | 1 °F |
| Accuracy | ±(1 % of Rd +6 digits) |
| Type K temperature | |
| Measuring range | 753,8 ... 1832 °F |
| Resolution | 1 °F |
| Accuracy | ±(2% of reading + 10 digits) |
| AC voltage | |
| Measuring range | 0 ... 6 V |
| Resolution | 0,001 V |
| Accuracy | ±(1% of Rd +3 digits) |
| Frequency range | 40 ... 1000 Hz |
| AC voltage | |
| Measuring range | 0 ... 60 V |
| Resolution | 0,01 V |
| Accuracy | ±(1% of Rd +3 digits) |
| AC voltage | |
| Measuring range | 0 ... 600 V |
| Resolution | 0,1 V |
| Accuracy | ±(1% of Rd +3 digits) |
| AC voltage | |
| Measuring range | 0 ... 750 V |
| Resolution | 1 V |
| Accuracy | ±(1.5 % of Rd +3 digits) |
| Continuity test | |
| Measuring range | 0 ... 100 Ω |
| Resolution | 0,1 Ω |
| Test condition | Beep at R <50 Ω |
| Resistance | |
| Measuring range | 0 ... 600 Ω |
| Resolution | 0,1 Ω |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Resistance | |
| Measuring range | 0 ... 6 kΩ |
| Resolution | 0,001 kΩ |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Resistance | |
| Measuring range | 0 ... 60 kΩ |
| Resolution | 0,01 kΩ |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Resistance | |
| Measuring range | 0 ... 600 kΩ |
| Resolution | 0,1 kΩ |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Resistance | |
| Measuring range | 0 ... 6 M Ω |
| Resolution | 0,001 M Ω |
| Accuracy | ±(2 % of Rd +5 digits) |
| Resistance | |
| Measuring range | 0 ... 60 M Ω |
| Resolution | 0,01 M Ω |
| Accuracy | ±(2 % of Rd +5 digits) |
| Frequency | |
| Measuring range | 0 ... 6 Hz |
| Resolution | 0,001 Hz |
| Accuracy | ±(0.1 % of Rd +3 digits) |
| Frequency | |
| Measuring range | 0 ... 60 Hz |
| Resolution | 0,01 Hz |
| Accuracy | ±(0.1 % of Rd +3 digits) |
| Frequency | |
| Measuring range | 0 ... 600 Hz |
| Resolution | 0,1 Hz |
| Accuracy | ±(0.1 % of Rd +3 digits) |
| Frequency | |
| Measuring range | 0 ... 6 kHz |
| Resolution | 0,001 kHz |
| Accuracy | ±(0.1 % of Rd +3 digits) |
| Frequency | |
| Measuring range | 0 ... 60 kHz |
| Resolution | 0,01 kHz |
| Accuracy | ±(0.1 % of Rd +3 digits) |
| Frequency | |
| Measuring range | 0 ... 600 kHz |
| Resolution | 0,1 kHz |
| Accuracy | ±(0.1 % of Rd +3 digits) |
| Frequency | |
| Measuring range | 0 ... 6 MHz |
| Resolution | 0,001 MHz |
| Accuracy | ±(0.1 % of Rd +3 digits) |
| General technical data | |
| Measuring functions | HOLD, Diode test, Continuity test, NCV test, LIVE test |
| Display type | LCD |
| Display size | 3,4 Inch |
| Measuring rate | 3 x per second |
| Automatic power-off | 14 min |
| Measurement range selection | Automatic |
| Operating height | 2000 m max. above sea level |
| Safety standard | CAT III 600V |
| Diode test | - Forward current approx. 1 mA - Open-circuit voltage approx. 3V |
| Display range | 6000 counts |
| Menu language | English, English (GB) |
| Protection class (device) | IP20 |
| Power supply | batteries |
| (Rechargeable) battery | 2 x 1,5 V AAA battery , Alkali-manganese |
| Capacity | 1270 mAh |
| Performance | 1,91 Wh |
| Operating conditions | 0 ... 40 °C , 0 ... 80 % RH |
| Storage conditions | -10 ... 60 °C , 0 ... 80 % RH |
| Dimensions ( L x W x H ) | 142 x 72 x 19 mm |
| Weight | 130 g |