The Digital Multimeter combines versatile measuring functions with a compact design for workshops, service and training. It measures DC and AC voltage up to 600V as well as DC and AC current up to 4 A. In addition, resistance measurements up to 40 MΩ, frequency measurements up to 4 MHz and capacitance measurements up to 4 mF are possible. For AC voltages, the True RMS function enables RMS value measurement. The 2.6-inch LCD display presents the results clearly.
In automatic mode, the Digital Multimeter independently detects DC and AC voltage, resistance and continuity and selects the appropriate measuring range. Further measuring functions are selected via the SEL button. A diode test and an audible continuity test are available for fault finding. The non-contact voltage detection NCV indicates detected voltage via bar graph display and warning tone. With the LIVE function, a live conductor can be identified single-pole. Data Hold freezes the displayed measured value.
The integrated torch makes it easier to work at poorly lit measuring points. The Digital Multimeter requires two AAA batteries with 1.5V each to operate; a warning indicator signals a low battery level. After 14 minutes without signal input, the Digital Multimeter switches off automatically. The device is designed for measurement category CAT III 600V.
| DC voltage | |
| Measuring range | 0 ... 4 V |
| Resolution | 0,001 V |
| Accuracy | ±(0.8 % of Rd +3 digits) |
| DC voltage | |
| Measuring range | 0 ... 40 V |
| Resolution | 0,01 V |
| Accuracy | ±(0.8 % of Rd +3 digits) |
| DC voltage | |
| Measuring range | 0 ... 400 V |
| Resolution | 0,1 V |
| Accuracy | ±(0.8 % of Rd +3 digits) |
| DC voltage | |
| Measuring range | 0 ... 600 V |
| Resolution | 1 V |
| Accuracy | ±(1 % of Rd +2 digits) |
| Direct current DC | |
| Measuring range | 0 ... 4 A |
| Resolution | 0,001 A |
| Accuracy | ±(2.5 % of Rd +5 digits) |
| Capacity | |
| Measuring range | 0 ... 4 nF |
| Resolution | 0,001 nF |
| Accuracy | ±(4% + 5 digits) |
| Capacity | |
| Measuring range | 0 ... 40 nF |
| Resolution | 0,01 nF |
| Accuracy | ±(4% + 5 digits) |
| Capacity | |
| Measuring range | 0 ... 400 nF |
| Resolution | 0,1 nF |
| Accuracy | ±(4% + 5 digits) |
| Capacity | |
| Measuring range | 0 ... 4 µF |
| Resolution | 0,001 µF |
| Accuracy | ±(4% + 5 digits) |
| Capacity | |
| Measuring range | 0 ... 40 µF |
| Resolution | 0,01 µF |
| Accuracy | ±(4% + 5 digits) |
| Capacity | |
| Measuring range | 0 ... 400 µF |
| Resolution | 0,1 µF |
| Accuracy | ±(4% + 5 digits) |
| Capacity | |
| Measuring range | 0 ... 4 mF |
| Resolution | 0,001 mF |
| Accuracy | ±(4% + 5 digits) |
| AC voltage | |
| Measuring range | 0 ... 4 V |
| Resolution | 0,001 V |
| Accuracy | ±(1% of Rd +3 digits) |
| Overload | 250V |
| Frequency range | 40 ... 1000 Hz |
| AC voltage | |
| Measuring range | 0 ... 40 V |
| Resolution | 0,01 V |
| Accuracy | ±(1% of Rd +3 digits) |
| AC voltage | |
| Measuring range | 0 ... 400 V |
| Resolution | 0,1 V |
| Accuracy | ±(1% of Rd +3 digits) |
| AC voltage | |
| Measuring range | 0 ... 600 V |
| Resolution | 1 V |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Alternating current AC | |
| Measuring range | 0 ... 4 A |
| Resolution | 0,001 A |
| Accuracy | ±(3.5% of measured value + 5 digits) |
| Overload | 250V/4 A |
| Resistance | |
| Measuring range | 0 ... 400 Ω |
| Resolution | 0,1 Ω |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Resistance | |
| Measuring range | 0 ... 4 kΩ |
| Resolution | 0,001 kΩ |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Resistance | |
| Measuring range | 0 ... 40 kΩ |
| Resolution | 0,01 kΩ |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Resistance | |
| Measuring range | 0 ... 400 kΩ |
| Resolution | 0,1 kΩ |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Resistance | |
| Measuring range | 0 ... 4 M Ω |
| Resolution | 0,001 M Ω |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Resistance | |
| Measuring range | 0 ... 40 M Ω |
| Resolution | 0,01 M Ω |
| Accuracy | ±(2 % of Rd +5 digits) |
| Frequency | |
| Measuring range | 0 ... 4 Hz |
| Resolution | 0,001 Hz |
| Accuracy | ±(2 % of Rd +5 digits) |
| Frequency | |
| Measuring range | 0 ... 40 Hz |
| Resolution | 0,01 Hz |
| Accuracy | ±(2 % of Rd +5 digits) |
| Frequency | |
| Measuring range | 0 ... 400 Hz |
| Resolution | 0,1 Hz |
| Accuracy | ±(2 % of Rd +5 digits) |
| Frequency | |
| Measuring range | 0 ... 4 kHz |
| Resolution | 0,001 kHz |
| Accuracy | ±(2 % of Rd +5 digits) |
| Frequency | |
| Measuring range | 0 ... 40 kHz |
| Resolution | 0,01 kHz |
| Accuracy | ±(2 % of Rd +5 digits) |
| Frequency | |
| Measuring range | 0 ... 400 kHz |
| Resolution | 0,1 kHz |
| Accuracy | ±(2% of reading + 5 digits) |
| Frequency | |
| Measuring range | 0 ... 4 MHz |
| Resolution | 0,001 MHz |
| Accuracy | ±(2% of reading + 5 digits) |
| General technical data | |
| Measuring functions | HOLD, Diode test, NCV test, LIVE test, Continuity test |
| Display type | LCD |
| Display size | 2,6 Inch |
| Automatic power-off | 14 min |
| Safety standard | CAT III 600V |
| Measuring range selection | Automatic |
| Display range | 3999 counts |
| Input impedance | 10 M Ω |
| Menu language | English, English (GB) |
| Protection class (device) | IP20 |
| Power supply | batteries |
| (Rechargeable) battery | 2 x 1,5 V AAA battery , Alkali-manganese |
| Capacity | 1270 mAh |
| Performance | 1,91 Wh |
| Operating conditions | -10 ... 50 °C , 0 ... 80 % RH |
| Storage conditions | -10 ... 60 °C , 0 ... 80 % RH |
| Dimensions ( L x W x H ) | 108 x 56 x 25 mm |
| Weight | 90 g |